Loading...
HomeMy WebLinkAboutHAROLD MILLER LT 3Onsite File Harold Miller Lot 3 #017-432-47 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP201045 Work Type: WellSeptic Initial Tax Code Number: 01743247000 Site Legal Address: HAROLD MILLER LT 3 G:2839 Site Mailing Address: 12400 HILLSIDE DR, Anchorage Owner: BERGERON ALEX J P & KALI M Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: `ot�ent. s, Gr ' v t)epartn�ient 3/23/2020 3/23/2021 46128 Q Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 0__)-* 1 d P140 «*'_ drCLL') �jz — fm C_ 9', 12, Z-. Received By: Date: Issued By: Date: �3 X20o�l% 0 PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) March 20, 2020 MOA Development Services Dept, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Harold Miller Lot 3 – 12400 Hillside Dr. Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the west steeply on the east half of the lot, but near the back (West) end the slopes are much milder. It is in that flatter area that the new septic system is located. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Drainage arrows are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 3/20/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201045, Rebecca Carroll, 03/23/20 HAROLD MILLER, LOT 3 c� 1 00'WELL RADIUS L / LOT 4 / ` E [STING W LL 1 I 2 -/75' ONG x 5' x 0.5'E F. DE TH pROPOED WELL \ 03 A SO PTION T ENCHES (M INTAI 1 F- \ M�N. 6' ETWE N TRENCHE) / I Z �\�. LO 3 ® I N :I THA :CO w MTS O wI ' FS 2C0 0 C? 8 SV v I- T 2 o ' MH / f 250 GAL. SEPTIC TANK — — — �. MT 120" MANWAY. 3 c0 :... CO EXISTING SHARE -- — —D IVEWAY (-PEEP AL R E S E: C III YSTEM APP. RA E 5.0 v�fi25' L NCx ' WID x 0.5' EFF. DEPTH ABSO TION TREITEH. LOT 4 I i I 21 11' D P w GR UNDWATER 8.5' ON 5/7/19) \\ FORGE 1 ENGIN EEHING LOT 2 \ \ I i 1 I ® I I CONTOURS ARE IN 5' INDERVALS NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND PROPOSED SEPTIC SYSTEM CO - CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2CO - DOUBLE CLEANOUT PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO - FOUNDATION CLEANC SYSTEMS. FS - FLOW SPLITTER VALVE 0 50 100 MH - MANHOLE FEET MT - MONITORING TUBE SV - SEPTIC VENT 1"=50' TH - TEST HOLE HAROLD MILLER, LOT 3 U.ik A DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM PERK RATE: 6-15 MIN/IN 1250 -GAL SEPTIC TANK APPLICATION RATE: 0.8 GPD/SF 600 GPD / 0.8 GPD/SF /5' WIDE * 1.0 (RED. FACTOR) = 150 LF TRENCH REQUIRED (150 LF SPECIFIED) BOTTOM OF TRENCH: 4.5' BELOW GRADE FLOW LINE ELEVATION: 4.0' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE REMOVE ALL FILL MATERIAL AND ORGANIC LAYER TO UNDERLYING SILTY GRAVEL. REPLACE IWTH MOA APPROVED SAND. BOTTOM OF TRENCH CAN BE NO MORE THAN 4.5' BELOW GRADE AT ANY POINT. �z i EOTEXTILE FABRIC 'PERFORATED PVC TOLES DOWN) RAINFIELD ROCK OA APPROVED SAND TYPICAL TRENCH SECTION NOTES: (NO SCALE) GRADE AREA OVER TRENCH TO DRAIN AWAY PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY E N G I N E E R I N G'. SOILS LOG AND PERCOLATION TEST FORGE \4!�r ENGIN EERIN G LEGAL DESCRIPTION: HAROLD MILLER L3 PERFORMED FOR: ALEX BERGERON DATE: 8/26/20 PROJECT No.: PARCEL ID#: 017-432-47 TECHNICIAN: L. TIDWELL DEPTH TEST HOLE 2 (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 SLOPE SILTY GRAVEL r GM TEST HOLE DEEPENED TO 18.5'- 8/25/20 DATE READING WAS GROUND WATER ENCOUNTERED? NO DEPTH To WATER (INCHES) NET DROP (INCHES) 11/26 IF YES @ WHAT DEPTH? N/A L 10:51 -11:21 30 136 - 140 L54 DEPTH TO WATER AFTER MONITORING: 8.5' 0 11:25 -12:55 30 136 - 140 L24 DATE OF MONITORING: 5/7/19 P 12:57 - 1:27 _ 136 - 140L34 Q 164 E TEST HOLE DEEPENED TO 18.5'- 8/25/20 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 11/26 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:51 -11:21 30 136 - 140 L54 L5 16 2 11:25 -12:55 30 136 - 140 L24 2 16 3 12:57 - 1:27 30 136 - 140L34 Q 164 5 6 PERCOLATION RATE: 6.23 (MIN/INCH) PERC. HOLE DIA. q_(INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: Groundwater Reading on 5/7/19 by Pannone Engineering Services. SOILS LOG AND PERCOLATION TEST LEGAL DESCRIPTION: HAROLD MILLER L3 PERFORMED FOR: ALEX BERGERON DATE: 8/25/20 PROJECT No.: PARCELID#: 017-432-47 TECHNICIAN: L. TIDWELL DEPTH TEST HOLE 3 (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 SLOPE FILL OG/OL ` SILTY GRAVEL •; , G M WAS GROUND WATER ENCOUNTERED? NO NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) IF YES « WHAT DEPTH? L 1 10:32-11:02 DEPTH TO WATER AFTER MONITORING: NONE 0 4-1 2 DATE OF MONITORING: 8/31/20 P 2-66 . 3 E 30 COMMENTS: TEST HOLE DEEPENED TO 18.5'- 8/25/20 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 8/25 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:32-11:02 30 2-E3a16 4-1 2 11:03-11:33 30 2-66 416 3 11:34-12:04 30 2-616 4�6 PERCOLATION RATE: 7.27 (MIN/INCH) PERC. HOLE DIA.—f--(INCHES) TEST RUN BETWEEN: 7 FT. and 8 FT. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201045, Rebecca Carroll, 03/23/20 Septic arealikely wellareaMechanical Area ofhouse in garage -