HomeMy WebLinkAboutINLET VUE ESTATES LT 1 Inlet Vue Lot 1 #051 - 021 - 34 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171106 PID Number: 051-021-34 Dwelling: ❑i Single Family (SF) ❑ Duplex(D) ❑ Multiple(SF and/or D) Project: ID New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD Address ❑ Deep Trench 0 Shallow Trench ❑ Bed ❑ Mound 1689 Knik Goose Bay Rd Suite 440 Wasilla, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-310-2501 3 1.0 GPD/SF 8.8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 4.8 Ft.4.0 Ft. Inlet Vue Estates 1 Fill added above original grade Gravel length Township Range Section 0 Ft. 45 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5.0 Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 450 Ft2 1 Ft. Well >100' >100' N/A N/A >25' TANK g Septic ❑S.T.E.P. 0 Holding 0 Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1000 Gal. Material Number of compartments Lot Line >5' 10' N/A N/A Steel 2 NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tankTank to Installer D3034 grainfield D3034 Northern Excavation & Construction Drainfield D3034 CO/MT D3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection 15' 9/21/17 2"0 9/22/17 Location and description da 3id 4th Garage slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date ..r..4....?Yr.:44N Al ie*:49TH -.* I /t1F;",,,,, _ 0 t! Benja 1 :clue—r-7:,.. 1 �o -�',5• C t .•�.` � Approve _ , I wl Date — j ,0j `�rR ''";�.;;L` Inspection Report_9-1-12.doc INLET VUE ESTATES, LOT 1 PiER/ MIT # OSP171106 PID # 051-021-34 1 S i I \\LOT 1 1 - 0' 1000-GAL 3-BDRM HOME SEPTIC TANK i FCO 45' LONG x 5'WIDE, 4' � WELL O, 0 SV EFFECTIVE DEPTH I • • 4 V2 ABSORPTION TRENCH \ 2C0 01 \ i . ,,, , \ tint H3;,' ALTERNATE SITE \ r • • ..•. ., 1 .•• • • •• ••.. 1 A B C 1 FCO --- 12.5 30.5 SV1 --- 12.2 43.5 SV2 --- 16.9 48.7 • 0 • . 2C0 --- 19.2 51.4 • TH#1C01 --- 26.7 60.3 TH#2 MT1 55.1 41.0 --- CO2 56.8 44.0 --- NOTE: CONLEY AVE -- \u NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND ~�G.•• :98 1, PROPOSED SEPTIC SYSTEM IO CO-CLEANOUT iio).• •• ..' :9' s 200-DOUBLE CLEANOUT j*• '' 111 1� * / ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS / • •• ••• / FCO FOUNDATION CLEANOUT /•• �� / PROPERTY ARE SHOWN.NO CONFLICTS WITH WELLS OR SEPTIC FS-FLOW SPLITTER VALVE •• Benj.'n Schiller••. SYSTEMS. MH-MANHOLE Ir,�Fc•,• C 12592 •����% 0 50 100 MT-MONITORING TUBE 11,;�\ROFE........... .'. = MI FEET SV-SEPTIC VENT ‘'‘`� - 1"=50' TH-TEST HOLE INLET VIEW ESTATES LOT 1 PERMIT # OSP171106 PID # 051-021-34 CV O O (n fn N - / 100.1 - - - INSULATION x-97.2 , 96.3 96.6 1000 GAL 96.4 SEPTIC TANK V 92.4 O�2 /-101.0 ORIGINAL&FINAL GRADE OU 96.2-' ,_ 96.2DRAINFIELD ROCK 92.2 45, 92.2 .:. -86.0-GROUNDWATER 7/14/17 --- 85.0 M 2 I-- 4 of ACg6lll Wig' • TM %\ %.*?, i .. Benja Schiller : PROFILE AS-BUILT +f�1'F9Fp 06.2018 `�/ Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes, Inc. Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Inlet Vue Estates Subd. Lot: 1 Block: Additional: Permit#OSP 171106 Well Depth: 44 ft. From: To: Formation: Below Ground: 42 ft. 0 9 stickup, sand, gravel Above Ground: 2 ft. 9 18 silt, gravel, cobbles kalIMin: 18 26 gray silt, gravel 15 26 35 wet brown silt, gravel tatic Level: 16 ftp 35 39 gravel, water !Casing: 44' of 6" ID Steel 39 40 coarse sand, water 40 41 fine sand, water iner Pipe: none 41 42 medium sand, water creened: non: 42 44 gravel, water Perforated: non: Ik routed: Bentonit; Depth: 20'+ r_____ WATER UALITY TESTING evelop. Method: Ai Q } Conform CoU100mL 1 Nitrates /• _mg/L se of Well: Residential 1 Arsenic NP u tilling Method: Rota ` luids Used: non: Pump Installed: non: Other: none (Date Drilled: 6-23-2017 Driller: Ben Mattson Development Services Department • Building Safety Division • 40° � On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 iii I a Mark Begich Anchorage,AK 99507 s. ETY Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP171106 Date of Issue:6-8-2017 Parcel Identification Number:051-02-134 Legal Description Property Owner Name&Address: INLET VUE ESTATES SUBDIVISION LOT 1 Troy Davis Homes,Inc. 21221 Conley Avenue 1689 Knik Goose Bay Rd#400 Chugiak,AK Wasilla,AK 99654 Pump Installation Date: 11-29-2017 Pump Intake Depth Below Top of Well Casing: 38 feet Pump Manufacturer's Name: Myers Pump Model: 3NFL52-8 Pump Size 1/2 hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Manufacturer's Name: Harvard Pitless Adapter Installer: Unknown Well Disinfected Upon Completion? Yes ❑No Method of Disinfection: Stereline Comments: 8 GPM Pump Installer Name: Wheaton Water Well,Inc. 1190 N.Wasilla-Fishhook Road Wasilla,AK 99654 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGEnr On-Site Water&Wastewater Program rn �. PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ... r, http://www.muni.org/onsite t•par tt On-Site Water & Wastewater System Permit Permit Number: OSP171106 Effective Date: 6/8/2017 Work Type: WellSeptic Initial Expiration Date: 6/8/2018 Tax Code Number: 05102134000 Site Legal Address: INLET VUE ESTATES LT 1 G:1657 Site Mailing Address: 21221 CONLEY AVE, Chugiak Owner: TROY DAVIS HOMES INC Lot Size in Sq Ft: 58515 Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 3 This permit is for the construction of: 0 Disposal Field El Septic Tank El Holding Tank ❑ Privy El Private Well El Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4, From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. AMC 15.65.060.B.3 Received By: 012461U/A, /9 / Date: Issued By: Date: <06� 89 7077 wo 44. MUNICIPALITY OF ANCHORA MAY 3,4i? Community Development Department `' Phone -343-7904 .% Development Services Division Fax: 9 ;�6 •7°� On-Site Water& Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-021-34 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 S. Knik Goose Bay Road #400 Wasilla, AK 99654 Site address 21221 Conley Avenue Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Inlet Vue Estates, Lot 1 Legal description (Township, Range & Section) Lot Size 58,515 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field LI Initial ❑ Single Family (SF) E (w/wo ADU) Septic Tank Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well El Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. -ri/Lt.tt C. C11 (Signature of property owner or authorized agent) Permit/Rush Fees: 6i,c) -1' 315 Waiver Fees: Date of Payment: S/31 / /1 Date of Payment: Receipt Number: Receipt Number: Permit No. 05� I 1 i 1 O� Waiver No. Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 18, 2017 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Inlet Vue Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, Inlet Vue Estates Subdivision intends to construct a new three- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or the proposed septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the primary absorption trench indicate t. The percolation rate of the soil was determined to be .5 s;,m minutes per inch. The mechanical analysis performed on the material indicated 59.5% it sand. A sand liner is therefore unnecessary. Groundwater was found during the placement of the test hole at 16' and was found at 15' during the monitoring period. An application rate of 1.0 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1 ,000-gallon septic tank and a 45' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3.0' below the surface and the total depth will be 7.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system is flat with only a very shallow grade to the northeast. The new trench will be constructed in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' CO 1 Lot 1, Inlet Vue Estates July 18, 2017 Page Two from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, at-e12---7 ,00:01.11%‘t Michael E. Anderson, P.E. �,.: 49 TH .• �.' s • Attachments h• • ••_ •••• •• • •••• • rI •MICHAEL E. ANDERSON • J,•. CE-4381 �`"Ay I,1I�ti\FEl).•��'~ KNIK ARM LOT 6, SECTION 32, T16N, R1 W, S.M., ALASKA \ ' r _-42� -- - J. _____„____ _. ______________ ______55.4.4,_____ - _ _ _ _____ ___•:...„ • .. 'ie1.1' 80.0' Tract A a m z h� 138.9' f`a4S. $ Lot 3 Lot 4 ---ON fi.Y. Lot 2 rte' rwr-- • �� • LotIkkl Y 5 -,. I. " 1,0 • i • r of 6 • r , . =liji" .Sar. ,. 1111111 =" IIILot 7 O ..... ., SO _-M 2t1 AG 0..11 -, ip...`' ng- 4Z,A4157 is r:11smsss+slri:KyliisMslrr.IL kin MIME M.... �- _ , i. ______ _ _AVE_----- 87.1,------------ -=- -� ' r 49th /\ .*% 7,--.-7.- -. . . ., • . . OA p, MICHAEL E. ANDERSON ; s AREAPLAN '. No. CE- 381 'tit SCALE 1' = 120' •SID ... ��n�. / LOT 1 // co I \ INLET--VUE EST: _�/ (' -.,\ - ,/SUBDIVISION 1 58,515 s.f. / /�\ ,$b. / _ , tract A / �6 ✓2p o' I / ao5 tif 1 1 Proposed / \ 1 � 1 Well.11 / 24.0 ' / 1 / 1 Lot 2 \ / , i I / Three / Bedroom Home V FCS 1,000 Gallon icriA I / Septic Tank Lri 1 TH3 d I` LEGEND CO 1 / w SV - Septic Vent ;0000* O CO - Clean Out \ / O 45' Long x 5' Wide x 4' MT - Monitor TubeO Effective Depth TH - Test Hole \ N / Absorption Trench —28.0 CONTOUR INTERVAL - 4' f 7 / rn / Lot 4 0 / r•1 / 0 / b / No Conflicts with Wells or O Septic Systems on 7 �����rr Neighboring Lots. Z / / 7 - ��'44 OF q��**.. . `P �p _ I, I TBI / i - 49th I� 0to I Alt. Site 1-411...dz a(1,,,sr I 1-73,.,1‘MICHAEL E. ANDERSON : .1 I TH2 tr-' No. CE-4381 . so so Lv ............. .. I whilPR;FESSM64.4 III I 15'T&E EASEMENT I N 90'00'00"W 160.25' SITE PLAN M SCALE 1' = 50' - - - - - - - - _ - r CONLEY AVENUE i 1 LOT 1 , INLET VUE ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home 5'Wide Trench System Perc. Rate: <1 Min./Inch 1,000 Gallon Septic Tank Application Rate: 1.0 GPD/SF 4' Drainfield Rock 3 Bedroom4 X 150 GPD/1.0 GPD/SF (Application Rate)= 450 SF Absorption Area 375 SF/5 SF/LF*.5 (Red. Factor) =45 LF Trench Length THEREFORE: Construct a 45' Long x 5'Wide x 4' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 7' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2"of Insulation and 2' of Cover. Maintain 10'Separation From Water Services in the Area. Natural Backfill 2'6" Geotextile / Fabric 6., 4" Perforated — PVC (Holes Down) Drainfield Rock 4'0" 5' l I TYPICAL 5' WIDE TRENCH SECTION ,..*74oF 1104. (NO SCALE) + •,. " ' j • • NOTE: Grade Area Over Trench to Drain Away. :4 49th i'‘ �'• ## Minimum 6' Separation From Bedrock. • Minimum 4' Separation From Groundwater. �1 2.L.`' • Minimum 100' Separation From Private Wells in the Area. !.jo :` Michael E.Anderson Minimum 100'Separation From Surface Water or Streams. V c) ; ?_ Minimum 10' Separation From Water Service Line. •40'j:., No.CE4381 ; �� MUNICIPALITY OF ANCHORAGE ostr7rrvii DEVELOPMENT SERVICES DEPARTMENT 4 .. 44.' 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 is • i►. Ili 49th P .: MUNICIPALITY OF ANCHORAGE "000119101%V DEVELOPMENT SERVICES DEPARTMENT 4.P' • '•••..,. 14, 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 i4 i •49th ' = ;1 � s SOILS LOG - PERCOLATION TEST E(7c.,fp MICHAEL E. ANDERSON ;Ci LOT I, INLET VIEW SUBDIVISION . N0. CE-4361 ., LEGAL DESCRIPTION: .•` ;•.5'_k.4),.4k"a PERFORMED FOR: TROY DAVIS HOMES 1""'���`P�p�':E +O�.. DATE: 3/8/16 PROJECT No.: ProfessionalAlliiEngineers Sump. PARCEL ID#: TECHNICIAN: L. BETTS DEPTH TEST HOLE 2 (feet) OB/OG SLOPE SITE PLAN 1 .1 4 1 A -5 a 4 - - e SEE SITE PLAN u o � 2 (I • A Q 7 b 4 POORLY GRADED GRAVEL a WITH SAND 8 • b GP/GW 9 • 10—'/., W'AS GROUND WATER ENCOUNTERED? NONE 4 IF YES(c_i•WHAT DEPTH' DEPTH OF WATER AFTER MONITORING: NONE 2% 11 a DATE OF MONITORING: 10/15/16 12 • ° DEPTH TO 13 DATE READING GRONET IME (MINS ES)TIME (MINUTES) WATER NET TvCDROP (INCHES) 14 BOH @ 14' TEST HOLE PRESOAKED PRIOR TO TESTING: 15 3/8 1 1:23 0.63" 16 2 1:53 30 8.38" 7.75" 3 2:23 0.75" 17 4 2:53 30 8.50" 7.75" 18 5 2:54 0.50" 19 6 3:14 30 8.25" 7.75" 20 PERCOLATION RATE:3.9 (MIN/INCH) PERC.HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TES HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I,MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/24/16 CO-461 MUNICIPALITY OF ANCHORAGE irorrrrq� DEVELOPMENT SERVICES DEPARTMENT +�P- . Vila 4700 BRAGAW STREET ANCHORAGE, AK 99519-665 0 liteX11 • 49th SOILS LOG - PERCOLATION TEST 1.7484.2 }}}}}},,,,,,,,,,,, T ;MICHAEL E. ANDERSEN_ 1 1 1 • NO. CE-4381 ...„/ r LEGAL DESCRIPTION: LOT I, INLET VIEW SUBDIVISION 11.1▪•., :7-3(-(2-,-/4:4? 3(-(2- 4+ PERFORMED FOR: TROY DAVIS HOMES iShi�PE � �'. DATE: 6/29/17 PROJECT No.: PARCEL ID#: TECHNICIAN: J. M I LL E T T E Professional Engineers Stamp: DEPTH TEST HOLE 3 (feet) 1 _ OB/OG SLOPE SITE PI AN 7 4 n ) 4 A 5 L SEE SITE PLAN 11 6 _ D C 7 .; 4 SILTY SAND a WITH GRAVEL 8 a SM 9 — . . 10 4 ' 4 WAS GROUND WATER ENCOUNTERED? YES n 1F YES @i@ WHAT DEPTH' 16' DEPTH OF WATER AFTER MONITORING: 7/14/17 11 a DATE OF MONITORING: 15' 12 0 DEPH DATE READING GROSS TIME NET TIME WATER NET DROP 13 c (MINUTES) (MINUTES) (INCHES) (INCHES) 14 a TEST HOLE PRESOAKED PRIOR TO TESTING: v 6/29 1 6:20/6:23 3 0"/6" 6" 1 6 BOH @ 16' 2 6:24/6:27 3 0"/6" 6" 3 6:28/6:31 3 0"/6" 6" I ? 4 6:32/6:35 3 0"/6" 6" I S 5 6:36/6:39 3 0"/6" 6" 19 6 6:40/6:43 3 0"/6" 6" ?0) PERCOLATION RATE: 0.5 (MIN/INCH) PERC.HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. MATERIAL IS Fth$E S+-TY S*NIf Y VF AVtL. NO PARTICLES GREATER THAN I" IN DIAMETER. S14TY Sigwef u1 (milieu . TEST PERFORMED BY ANDERSON ENGINEERING. I,MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/18/2017 C 0 .' '. _ j`'``' _ N0111'IzI RN GEOTECHNICAL ENGINEERING, INC,/ TERRA FIRMA TESTING r. IIIL. iwA...,',,,:tT 7 Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis PROJECT CLIENT: Forge Engineering %GRAVEL 21.1 USCS SM PROJECT NAME: Inlet View Estates#1 %SAND 59.5 USACOE PC N/A PROJECT NO.: 4638-17 %SILT/CLAY 19.4 %PASS.0.02 mm_ N/A SAMPLE LOC.: Lot 1 %MOIST.CONTENT 10.7 %PASS.0.002 mm N/A NUMBER/DEPTH: 17-S-4 UNIFORMITY COEFFICIENT(C,) UNKNOWN DESCRIPTION: Silty sand w/gravel COEFFICIENT OF GRADATION(Ce) UNKNOWN DATE RECEIVED: 7/24/2017 ASTM DI557(uncorrected) N/A TESTED BY: JA ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422/C136 I.3• In' .IQ ala a:oo SIEVE ANALYSIS RESULT 100 ♦ , SIEVE SIEVE TOTAL% Specification 90 u_ * --- --- SIZE(mm) SIZE(U.S.) PASSING (%PASSING) 80 r - 70 ♦ 76.20 3" A. 38.10 1.5" 100 60 * • 19.00 3/4" 96 i50 12.70 1/2" 91 ra 40 — ---- — 4.75 #4 79 — ,4 _. ._.-..__ --- _.. ---..._ ... 2.00 #10 72 30 0.85 #20 66 20 • , . 0.43 #40 57 • 0,25 #60 44 10 - 0.15 #100 32 0 I__-_r_ 0.075 #200 19.4 100 10 r i -1 0.1 0.01 0,001 GrIN SIZE i(mm) HYDROMETER RESULT GRAVEL I SAND ELAPSED DIAMETER TOTAL% COBBLES I SILT or CLAY TIME(MIN) (nun) PASSING Fine ne Coarse Medium Fine U 0.5 1 MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 8 . _ ---._ ___ 15 140 ____—__— .--- --_--- �_ 30 --- :::_r 60 a 135 250 I I I - _ 1440 130 tr1 HYDRAULIC COND. A (ASTM D2438) 125 DEGRADATION 120 (ATM T-313) PLASTICITY INDEX 115 ASTM 4318 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGE-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 - Phone:907-344-5934 • Fax:907-344-5993 • www.nge-tft.coin f r., . 1 tse yg , MO ;. <-, i Gt Bp ttc. Municipality of Anchorage On-Site Water and Wastewater Program G . - (907) 343-7904 s A t E.Y Certificate of On-Site Systems Approval Parcel I.D. 051-021-34 ( Expiration Date: i re( - le 1. GENERAL INFORMATION Complete legal description Inlet View Estates Lot 1 Location (site address) 21221 Conley Ave Current Property owner(s) Troy Davis Homes Day phone 907-310-2501 Mailing address 1689 Knik Goose Bay Rd Suite 440 Wasilla, AK Real Estate Agent Day phone 2. TYPE OF DWELLING: ,- 0 Single Family (w/wo ADU) ❑ Duplex ' A ❑ Multiple Dwellings (Single Family and/or Duplex) 9 . i 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System El Public Sewer ❑ WaiverNariance request for: Distance: Received by: L' iMtel V Date: //a/!9 COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ /l[.& Waiver Fee $ Date of Payment / /q Q //3 Date of Payment Receipt Number O q7? b Receipt Number COSA# 40(',11314nd Waiver# .44.40j 5. STATEMENT ( I PECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave. Suite 203 Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller Date 1/05/18 *:49TM 6. DSD SIGNATURE System#1 Approved for 3 bedrooms Beni in Schiller �� . Cit.12592 •':%)/ System #2 Approved for bedrooms `c 9,-;.•.,I(S ►�.• Disapproved v�`°"�'?=:55;� '`4 Conditional approval for bedrooms, with the following stipulations: OFq 6 0 = ON-SITE 76, WATER AND WASTEWATER PROGRAM ‘,65-- •.1c) G���� . 7SERO By: t V l Gam' Original Certificate Date: I q- 10 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Inlet View Estates Lot 1 Parcel ID: 051-021-34 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/23/17 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 44 ft. Cased to 44 ft. Casing height (above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 6/23/17 New Static water level 16 ft. ft. Well production 15 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform N/D colonies/100 mL Nitrate 1 .88 mg/L Arsenic N/D ug/L Date of sample: 11/29/17 Collected by: Wheaton Water Wells B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel Date installed 9/21/17 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper New construction C. ABSORPTION FIELD DATA Date installed 9/22/17 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.0 GPD/SF System type 5 Wide Length 45 ft. Width 5.0 ft. Gravel below pipe 4.0 ft. Total depth 8.8 ft. Eff. absorption area 450 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Constr. Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100 On adjacent lots 100 Absorption field on lot >100On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas 100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5 Property line �5 Absorption field >5 Water main 10' Water service line >10' Surface water >100' Wells on adjacent lots >100 ABSORPTION FIELD ON LOT TO: >10'Property line Building foundation 10 Water main 10 >10'Water Service line Surface water >100Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots �100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and �G•OF4kk' review of Municipal records that the above systems are inAllr" ..• conformance with MOA COSA guidelines in effect on this date. ArP'• 'fiV Benjamin Schiller, PE j*• 111 ,• Engineer's Printed Name ��'•• j Date 1/05/18 ••• �•••• ••% j� Beniami p filler / Ok(44.:,..„:;..•C 1 5e92 ...:.,15 f COSA brown sheet 10-10-12.doc �/ I Tract A �j / 18 \ 6F, co 05 / y/ / 5' UFFER \ EASEMENT / ul /a DECK \ / O 112.0$' _o U 0so.o 37.2' Ct o WELL 5.5' 0 1 STORY RESIDENCE 110 N a 6.5' v 7.6. a2 13.0' a In o ad 6�l O 13.5'N 13 0' tot o a 0 7' Zea • —PORCH SEPTIC PIPES / 7n/ co N o Lot 2 \ o / o o 0 o U, N 6 Wy Lot 4 I •d • 0 r7 0 0 10' DRAINAGE EASEMENTS z • • Lot 1 58.515 s.f. } tr. 0 w• ca . — 15' T&E EASEMENT _ - . I I • N 90'00'00'W 160.25' 0 M O M q. CONLEY AVENUE