HomeMy WebLinkAboutMT BALDY ESTATES PHASE 1 LT 2 Onsite File Mt Baldy Estates # 1 Lot 2 #050 - 762 - 14 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171063 PID Number: 050-762-14 Dwelling: ❑■ Single Family (SF) E Duplex(D) ❑ Multiple (SF and/or D) Project: g New ❑ Upgrade Name: Troy Davis Homes Inc. ABSORPTION FIELD Address ❑ Deep Trench ❑■ Shallow Trench ❑ Bed ❑ Mound 1689 Knik Goose Bay Dr#400 Wasilla AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-310-2501 4 0.8 GPD/SF 0 / 0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot -0.5 / -0.5 Ft. 0.5 / 0.5 Ft. Mt. Baldy Estates Phase 1 2 Fill added above original grade Gravel length Township Range Section 6.0 / 8.3 Ft. 75 / 75 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5 / 5" Ft. Ft. TO Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 750 Ft2 2 >10.0 Ft. Well >100' >100' N/A N/A >25' TANK 12 Septic 0 S.T.E.P. 0 Holding 0 Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1250 Gal. Material Number of compartments Lot Line >5' >10' N/A N/A Steel 2 NA Foundation >5' 9' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to D3034 Installer drainfield Northern Excavation Drainfield D3034 CO/MT D3034 Inspector Michael E Anderson BENCH MARK (Assumed elevation) 100 ft Inspection 151 6/2/1! 2 6/6/1 Location and description dates: "' 3'" 4th Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: DateAn, . • *: 49Th ilk ••* 4 rl rd 01 Benj n Schiller : �� ,•. CE 12592 %/ Approves _ '41_ . Date 1 18 4, ,,*o Alf`g•• *4 A. • • PROF_ StC Inspection Report_9-1-12.doc MOUNT BALDY ESTATES PHASE 1 , LOT 2 S5 PERMIT # OSP171063 PID # 050-762-14 LOT 2 VACANT LOT 3 7"- . 7' / \ 7 \ 7 \ / \ / \ / 7 / . i WELL \ 2x-75' LONG x 5 WIDE, 0.5' EFFECTIVE DEPTH �j / ABSORPTION TRENCHES 9.3 i Q` MTITH2A 03 O DRM HOME /,`��' / 4 6 `C/ MT1C01..•• •./FCIO.. \ Q / • j4i • '.----\ --r1ooC• o• 1! 2507GiNK C04.MT4. . . EPTI'411 A B C / r / FCO 10.6 5.9 — TH2B . / / SV1 23.8 22.0 — MT2 SV2 31.6 29.8 --- CO2 2C0 34.9 32.6 -- CO1 26.8 12.9 --- MT1 26.7 12.5 --- / CO2 85.4 83.7 --- _ MT2 85.2 83.0 --- ALTERNATE SITE CO3 --- 33.5 11.7 / MT3 --- 35.6 13.3 C04 --- 60.8 81.4 NOTE: / MT4 --- 60.0 81.0 ��, �‘\\,l NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND � 9r. gyp 11 PROPOSED SEPTIC SYSTEM CO-CLEANOUT /I'lb.• .TM 37 1 2C0-DOUBLE CLEANOUT ', / ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS . ... .. / FCO-FOUNDATION CLEANOUT 4 ••..,� I / PROPERTY ARE SHOWN.NO CONFLICTS WITH WELLS OR SEPTIC / FS-FLOW SPLITTER VALVE / SYSTEMS. �-.• :enja i� Schiller •��j 0 50 100 MH-MANHOLE O �` .. CE 12592 • / MT-MONITORING TUBE isle . Feb 23.2719 ..•� ,� IIIII I= = FEET Ilk eF°PROFESSIO0.,\ ' SV-SEPTIC VENT \���"��'- 1"=50' TH-TEST HOLE MT BALDY ESTATES PHASE 1 LOT 2 PERMIT # OSP171063 PID # 050-762-14 0 O N 5 > N - /-93.4 — — — ,[88.1 S 87.5 Yr 1250 GAL 87.3 SEPTIC TANK J � `—83.3 OH INSULATION 1—p Um MU ,---91.5 FINISH GRADE - " 85.5 ORIGINAL GRADE DRA#NFIELD ROCK MOA APPROVED DRAINAGE SAND 86.0 86.0 85.5 85.5 75' 1.— /78.01 80NO GROUNDWATER 3/29/05 73.8 Q N H O INSULATION f—o H o— _. —90.6 FINISH GRADE -U 82.3 ORIGINAL GRADE : :: MOA APPROVED DRAINAGE SAND 82.3 75' NO GROUNDWATER 3/29/05 774.3 73.8 �������A\� 03 cN PROFILE AS-BUILT %*� '",;." •�� '�*�i (NO SCALE) % ". ' "" .. 1 Benja ' chiller j �#or •... Cmaap92,.�.V?rO 1FF1PROfESS.0.0\'� Municipality of Anchorage ''�'; �, P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Department On-Site Water and Wastewater Section **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181005 COSA#: OSC181056 Permit#: PID#: 050-762-14 Legal Description: Mt Baldy Estates Phase 1 Lot 2 Engineer: Forge Engineering Applicant: Troy Davis Homes Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the foundation has been approved. The approved separation distance is 9.0 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: of 2/1k Approved by: '2e...Le-/C/C2g, C.CtiCra Name of Reviewer **** VARIANCE/WAIVER REVIEW **** " GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) February 20, 2018 Municipality of Anchorage Development Services Dept- On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Mt Baldy Estates Lot 2-12850 Golden Eagle Drive Variance Request—Field to foundation Dear On-Site Services Engineer: During the construction of the septic fields for this property, the home was inadvertently built too close to one of the septic fields. The topography of this lot is such that the locations of the home and septic systems is very tight. The fields were placed as close as possible to the lot lines, but when the final survey was done, the northern field is approximately 9.3' away from the building foundation. In this case, the field is a raised bed with the sewer rock located at approximately the existing grade. This shallow trench will not affect the foundation in any way. We request a waiver for a 9' separation from the northern trench to the house foundation. Sincerely, Benjamin Schiller, PE oF Aii *: 49TM ••it 1, �r :• Benjam Schiller #�F�,,•• CE 12592 .**(%/`k\ FDPROFESS\c ..r Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 I Name: Troy Davis Homes, Inc. Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Mt. Baldy Estates Ph. 1 Lot: 2 Block: Additional: Permit #0SP171063 Well Depth: 205 ft. From: To: Formation: Below Ground: 203 ft. 0 7 stickup, boulders, silt, gravel Above Ground: 2 ft. 7 17 soft gray bedrock 17 76 hard gray rock Gal/Min: 1 76 103 black shale Static Level: 27 ft. 103 138 hard gray rock asing: 43' of 6" ID Steel 138 205 very hard gray rock finer Pipe: none creened: noner erforated: none 1r'Vf'' .;,--:L.!TY TESTING CoUfo-: _ CoI/100mL routed: Bentonite NitrF.den _. _„t_S 1 mg/L Depth: 20' + Arr:unic. IV P ug/L Develop. Method: Air Use of Well: Residential Well hydrofracked on Drilling Method: Rotary 6-28-2017. Well is now Fluids Used: none producing 4.5 gpm. Pump Installed: none Other: none Date Drilled: 6-8-2017 Driller: Ben Mattson Development Services Department • Building Safety Division PO B V' On-Site Water & Wastewater Program w Y' 4700 Elmore Road ,_ P.O. Box 196650 �.L1 I Anchorage, s A E T Y e, AK 99507 Mark Begich 9 Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP171063 Date of Issue: 4-26-2017 Parcel Identification Number:050-762-14-000 Legal Description Property Owner Name& Address: Mt.Baldy Estates Ph. 1 Lot 2 Troy Davis Homes,Inc. 12850 Golden Eagle Drive 1689 Knik Goose Bay Rd#400 Eagle River,AK Wasilla,AK 99654 Pump Installation Date: 7-7-2017 Pump Intake Depth Below Top of Well Casing: 183 feet Pump Manufacturer's Name: Goulds Pump Model: 7HS05412CL Pump Size 1/2 hp Pitless Adapter Burial Depth: 9 feet Pitless Adapter Manufacturer's Name: Harvard Pitless Adapter Installer: Unknown Well Disinfected Upon Completion? E Yes No Method of Disinfection: Chlorine tablets Comments: Pump Installer Name: Wheaton Water Well,Inc. 1190 N.Wasilla-Fishhook Road ' Wasilla,AK 99654 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE _����\\\‘\ DEVELOPMENT SERVICES DEPARTMENT ii�P 4;kk, 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 /*•• �� *QVi SOILS LOG - PERCOLATION TEST 1011 — % .,,� n . :enj.Cin Schiller ' / LEGAL DESCRIPTION: LOT 2, MOUNT BALDY ESTATES ��,�F1 4•; FeD2o 12592 .�V r. ��FqF�PRO FESSIONP� PERFORMED FOR: TROY DAVIS HOMFS \�\.N. `4&--4'+ DATE: 5/11/17 PROJECT No.: PARCEL ID#: TECHNICIAN: M. ANDERSON Professional Engineers Stamp: DEPTH TEST HOLE 2A (feet) 1 OB/OG SLOPE SITE PLAN 2 . a 3 • .4 '•z SILTY GRAVEL • WITH SAND 4 . •A GM 5 • SEE SITE PLAN . SILT/GRAY 6 7 • BOH @ 7.5' 8 I 1 J BEDROCK 9 : I1= a' WAS GROUND WATER ENCOUNTERED? No 10 IF YES @ WHAT DEPTH', S Ell I- DEPTH OF WATER AFTER MONITORING: L 1 I DATE OF MONITORING: 12 I III E GROSS TIME NET TIME DEWATH ER To NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 15 16 17 18 19 20 PERCOLATION RATE: (MIN/INCH) PERC. HOLE DIA. (INCHES) TEST RUN BETWEEN: FT. and FT. COMMENTS: TEST HOLE TO VERIFY BEDROCK DEPTH. MUNICIPALITY OF ANCHORAGE 4_bN‘NI\��\\���l DEVELOPMENT SERVICES DEPARTMENT i:Q .Pt•• c4�1ii • 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 *. 1\ *t V SOILS LOG - PERCOLATION TEST %,•tom OA . Be .min Schiller �+�Fc•. CE 12592 ••��t% LEGAL DESCRIPTION: LOT 2, MOUNT BALDY ESTATES tk1F9FOPRo ESSION•••• PERFORMED FOR: TROY DAVIS HOMES l>>A\"``'2 DATE: 5/11/17 PROJECT No.: Professional Engineers Stamp: PARCEL IMP TECHNICIAN: M. ANDERSON DEPTH TEST HOLE 2B (feet) 1 OB/OG SLOPE SITE PLAN 2 . A • 3 . ••.4 SILTY GRAVEL ' 'i WITH SAND 4 GM 5 • SILT/GRAY SEE SITE PLAN 6 7 • BOH @ 8' 8 ° 1=111 BEDROCK "—I I. H" 1 O - WAS GROUND WATER ENCOUNTERED? No IF YES @ WHAT DEPTH> - DEPTH OF WATER AFTER MONITORING: L 11 -I I I— DATE OF MONITORING: E 12 1=11 GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 15 16 17 18 19 20 PERCOLATION RATE: (MIN/INCH) PERC. HOLE DIA. (INCHES) TEST RUN BETWEEN: FT. and FT. COMMENTS: TEST HOLE TO VERIFY BEDROCK DEPTH. �•J'' "'`CIR MUNICIPALITY OF ANCHORAGE 111cn On-Site Water& Wastewater Program �0 S. � PO Box 196650 4700 Elmore Road ,. Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite i 11/(f7.1. 140111, On-Site Water & Wastewater System Permit Permit Number: OSP171063 Effective Date: 4/26/2017 Work Type: WellSeptic Initial Expiration Date: 4/26/2018 Tax Code Number: 05076214000 Site Legal Address: MT BALDY ESTATES PHASE 1 LT 2 G:0355 Site Mailing Address: 12850 GOLDEN EAGLE DR, Eagle River Owner: TROY DAVIS HOMES INC Lot Size in Sq Ft: 326663 Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 4 This permit is for the construction of: RI Disposal Field El Septic Tank El Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. Bedrock confirmation testholes are to be done prior to construction of the septic field (see site plan for locations). If the results require a design change, construction of the system will stop pending on-site review and approval. Please submit stamped and signed results with the inspection report/record drawings. ...---?-s-k--._ Received By: bfr'--5--, . Date: u a7 I Issued By: y `[ (tt6C� ctr( / Date: Aril MUNICIPALITY OF ANCHORAGE f'�•� X89 1077 Community Development Department �, �•.f : \one: 907-343-7904 Development Services Division '= X017cax: 907-343-7997 On-Site Water & Wastewater Program p,pR � 1 ON-SITE SEWER/WELL PER PPLICATI OL 68 L Parcel I.D. 050-762-14 Property owner(s) Troy Davis Homes, Inc. Day phone 310-2501 Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654 Site address 12850 Golden Eagle Drive Eagle River, AK 99577 Legal description (Sub'd., Block & Lot) Mount Baldy Estates Phase 1, Lot 2 Legal description (Township, Range & Section) Lot Size 326,663 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well EI Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. LJ- (Signature of property owner or authorized agent) Permit/Rush Fees: '7 I R Waiver Fees: ` Date of Payment: 2PT Date of Payment: Receipt Number: 0(.035-86 5-86 Receipt Number: Permit No. OSP(7/063 Waiver No. Permit App_ : ':..k ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) , April 21, 2017 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Mount Baldy Estates Phase 1 Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Mount Baldy Estates Phase 1 Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. Lot 3 to the west is currently developed but the well and septic system do not impact the location of the well and septic system on this lot. The remainder of the subdivision is currently undeveloped. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. No existing wells or septic systems are closer than 100' from the proposed septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test hole placed on the lot in the area of the absorption trench and alternate site indicated sand with silt and gravel (SP/SM). The percolation rate of the soil was determined to be 10.2 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. Bedrock was found at 8.5' below the surface in the test hole with fractured bedrock encountered at 6'. Prior to construction a test hole will be placed at the locations shown on the Site Plan to verify the depth of bedrock in the absorption area. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon Septic Tank and 2-75' long by 5' wide by .5' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be .5' above the surface to provide a minimum of 6' separation from fractured bedrock. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' Lot 2, Mount Baldy Estates Phasel April 21, 2017 Page Two over the septic tank. A flow splitter valve must be placed to insure even flow to each trench. The ground surface on the lot in the area of the absorption trenches slopes to the west at approximately 10%. The new trenches will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, 7074jLetY,Michael E. Anderson, P.E. Attachments • ts' 13I4I - At__ E. ANDERS7 S 7 0�• 1'���1 No. CE-4381 �� ', aSS�*446. N 90'00'00"E 264.03' u) 0 cl LOT 2, MOUNT BALDY ESTATES TRACT A PHASE 1 6 7.50 ACRESr*i VACANT I\ \ . N... I Y i LOT 3co No Conflicts with P Well or Septic N System on This Lot. Z oProposed q O well® !\ Ui FOUR Li BEDROOM (+e ./ HOME' `3D p, rco pe 1,250 Gallon eb CE co Septic Tank 4f IS — 2C0 43 N. at 63 lox 2-75' Long x 5• Wide 10% x .5' Effective Depth cc, „co +V` Absorption Trenches lox/41.• A 441 ` LEGEND `oz MT - Monitor Tube 7- . O FCO - Foundation Clean Out ALTERNATE SITE: _ TH - Test Hole Advontex Treatment TH2 `� CO - Clean Out System w/30' Long - O <O 2C0 - Double Clean Out x .5 Effective Depth �,_0% 4`0• v A - Bedrock Confirmation Test Hole Absorption Trench. N 0 cA ♦�o►�O ill Application Rate 4 ® N ^ V � CC QF...... ....... � 14., GPD/SF. A ox Q •�' P L "•••. .. ar C9/ 1 S 89'57'06"W 130.76' M v. 49th IN ', �� 1 c '-t-) rn I-41 0 O MICHAEL E. ANDERSON ISIPRIVATE ACCESS q +c '• No• CE-4381 �'� : ..4i**••. 1-Z 6 1.10'... 1. ,'CI +is isw1\r4,4" LOT 1A SITE PLAN EAGLE'S NEST SCALE 1" = 60' LOT 2, MOUNT BALDY ESTATES PHASE 1 SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5'Wide Trench System Perc. Rate: 10.2 Min./Inch 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF .5' Drainfield Rock 4 Bedrooms * 150 GPD/Bedroom = 600 GPD Total Flow 600 GPD/.8 GPD/SF/5 SF (Width) *1 (Red. Factor) = 150 LF Trench Length THEREFORE: Construct 2-75' Long x 5'Wide x .5' Effective Depth Absorption Trenches at the Location Shown on the Site PLan. Elevation in the Trench to be 2.0' Below Original Ground Surface, Remove Organic Material and Replace With MOA Approved Sand as Required Under Trench. Provide 2"of Insulation and 2' of Cover Over Trench and 4' of Cover Over Septic Tank. Place Flow Splitter to Insure Even Flow to each Trench. 6"Topsoil and Revegetate Fill Area 3 — Natural 3 1r- 1.0' Backfill 71 2" Insulation & 1.0' Geotextile Fabric "//////1;r:////4 .5' O _ 4" Perforated OG .5' PVC (Holes Down) OG Remove Organics Drainfield Rock 2' Place MOA Approved Sand Underlying SP/SM 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) rrrrraa�� NOTE: Grade Area Over Trench to Drain Away. •**-rE QF q,q��4��� Minimum 6' Separation From Bedrock. ••. P'.•.... ....."" `tg+� Minimum 4' Separation From Groundwater. Arc-)‘...* �9 • Minimum 100' Separation From Private Wells in the Area. : ' 49th f'V •: #` Minimum 100' Separation From Surface Water or Streams. ter,, 1` MICHAEL E.ANDERSONDE - :' 'C `w - No. CE-4381 . 1..< 4L- •a41 pROFESSW:40-• �t+�aaaarr • Municipality of Anchorage A><KIENPJNW i< Development Services Department s C'}��a ..)::.,..-1, s:,.0 "a`-�y�7 • Suiiding Safety Division II yF e ,•,, - )_: 1, t r On-Site Water and Wastewater Program �,r I "',...`,"' b-- 7 •v'i 4700 South Bragaw St. r, 7, J. /1-1 �Fl►� re ((:.!. ,.. P.O-Box 196850 Anchorage,AK 99519-6850 �' '� "'t,,.. . " - .'1: :9 vAvw.muni,oro/onsitg .. ;� ;,i!cry W !.,., it : 47; (907)343.7904 C ^: t .7)4'i7: ,� �a Soils Log - Percolation Test ���- ''.,' � Pertormed For: CMM General Contractors Date Performed:3/182005 Legal Description' , ivision of Lot 2 Township, Range,Section: NW 114 of NE 1/4,See.6,T14N,RI W.SM Q..iot 2- Slope Site Plan , ( Depth (Feet) , yt'\/ r anic Silt(OL),root mat., A/brown,frozen to 0.5',moist. rr , -. _ See Site Plan 2- 1.t x Sand with Silt,Gravel and 3-:1i1.rhi . 4-:t it Cobbles(SP-SM),brown, '41 j1.moist. 5--.41-0--14 B- ii:f Fractured Bedrock. trt its 7- Cleft — - ` - 1, 'a Bedrock. -5 tis a_ a • _ _ -11u WAS GROUND WATER 9- ENCOUNTERED? No o- Total Depth 8.5'. s !F YES.AT WHAT DEPTH? o . p Komatsu PC 120 backhoe. Depth to water Ara. c 11- Monitoring? No Water e 12- Data 3129/05 --tV 13- _ 14- Reading Date Gross Time Net Time Depth to Water Net Drop 15 6" 3/18/05 3:12 pm 16- 4-12116" 3:22 pm 10 min 1-4/16" 17- 2-14/16" II 3:42 pm 30 milt 3-2/16" a i8- 6" 3/18/05 3:44 pm 19- 3-2/16" if 4:14 pm j30 min 2-14/16" 20- 6-1/16" 3/18105 4:16 pm 3-2/16" 4:46 pm 30 mics 2-15/16" PERCOLATION RATE 10.2 (minutes/inch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 2 FT AND 2.5 FT COMMENTS PERFORMED BY: Russell Hepaer,E.I.T. I Allan W.Muffin CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES 1N EFFECT ON THIS DATE. DATE: March IS,2005 11{ IRIAN, ' ✓1 ,:t 8O •. 6.-,, Municipality of Anchors s u 6 ' 8 9 10 77 ° On-Site Water and Wastewater Progr- 'b iii,' ) ,o w (907) 343-7904 , `'� ti; 7 SAF ETY FEB 2 1 2018 1- Certificate Certificate of On-Site Systems Ai oval ti c Cu Parcel I.D. 050-762-14 Expirationi5'•=te:8. L —q —11 1. GENERAL INFORMATION Complete legal description Mt. Baldy Estates Phase 1 Lot 2 Location (site address) 12850 Golden Eagle Dr Current Property owner(s) Troy Davis Homes Inc. Day phone 907-310-2501 Mailing address 1689 Knik Goose Bay Dr #400 Wasilla AK 99654 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual 0 Individual Water Storage ❑ Holding Tank • ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Septic field to foundation Distance: Received by: U,tto6444.4tvAp c Date: VALL___ COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 0:30 1-qt. Waiver Fee $ 3e/t4 a) Date of Payment .ataa-llo Date of Payment o2/ -lr4 Receipt Number U 044 3-1) Receipt Number a ti-UM COSA# 65618105f° Waiver# 05U/V006- 44' 4) la, . .11( '4. r . 5. STATEMENT OF it GTIO EER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering 907-522-7773 PO Box 240773, Anchorage, AK 99524 Address Phone Engineer's Printed Name Benjamin Schiller, PE Date 2/20/18 ....,4......44.4,;kk, ,meg.• 6. DSD SIGNATURE )'k' 49TH... *.voo �.* ti �/► f. /C System #1 Approved pproved for bedrooms O *" r % Ben- in Schiller ' 1� System #2 Approved for bedrooms CE 12592 .-z,...',.,,?-__;%— f •',;w i Disapproved f T4,4.'-5.Pe .0'.0 Conditional approval for bedrooms, with the following stipulations: 0 -c'( o,=As ti ti * ON-SITE 7" WATER AND o WASTEWATER o PROGRAM �� " o� By. . .--.1......__k Original Certificate Date: 2 " 9' -1 g . i The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_f c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Mt. Baldy Estates Phase 1 Lot 2 Parcel ID: 050-762-14 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/08/17 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 205 ft. Cased to 43 ft. Casing height (above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 6/08/17 New Static water level 27 ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 0.597 mg/L Arsenic ND ug/L Date of sample: 2/9/1 g Collected by: Forge Engineering *Well was hydrofracked on 6/28/17 and new production was measured at 4.5 GPM. B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 6/2/1 7 Tank size 1250 gal. Number of Compartments 2 Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N Date of pumping New Collstr. Pumper C. ABSORPTION FIELD DATA Date installed 6/6/17 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 System type 5 Wide Length 150 ft Width 5'0 ft. Gravel below pipe 0.5 ft. Total depth 6.0 8.3 ft. Eff. absorption area 750 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Constr. Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots 100' Absorption field on lot 1��� On adjacent lots 100' Public sewer main X75' Public sewer manhole/cleanout >100' Sewer/septic service line X25' Holding tank X75' Animal containment areas X50' Manure/animal excrete storage areas 100 SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Absorption field >5' Water main >10' Water service line 10' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation 9' Water main >10' Water Service line 1�' Surface water 100 Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION —,��. '`\\, I certify that I have determined through field inspections and .�v � •• • C.-AA '• � review of Municipal records that the above systems are in *• • � *9, conformance with MOA COSA guidelines in effect on this date. IA Engineer's Printed Name Benjamin Schiller, PE ••. `�► j0 . dr 2/20/18 j •• Benpa E Schiller / '' CE 12592 • � / Date �0i'F9;, 17O./J 8•,•..*J.,.(7;•:0 i '�� �Iraori:ss -4-- 1‘\e\\.�� COSA brown sheet 10-10-12.doc i 4 o 0'09m W I -o m t -r+ I8 l'86Z l M„cS,S l.00 N Lei _ D D —I cO 4,_ NI ....! P \ \i.:W C) -<< q Z in r \ o C - — — — - - 1N o 4 7 111 u \ isr d v rn 0 00 v —� m — '- � �090t N a I N a m S's v G �D 2r4 . 0 ,as o,, o �'4 G4 s r- / A r c �90" 15r R r 6. / N / ,l2•060 L 3„6S,S l.00 S iv \ \ fa0 \\ > \ \ \ \ Qg• N . O O ` • .. o, _ v - rn I \v7 N N T 0 Cr >;J . coy o� o a ( _° �r o• N m M PLOT PLAN AS BUILT _X SCALE 1" = 100' GRID NW 0355 Project No. 17-048/B6I I 0 / 5�� m D 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 0.� �I�,, in Lang & Associates n c . (907) 522-6476 Phone 400ppp� o `�' \11q (907) 522-4625 Fax o F A ��Op� _x o 3' 6}, Professional Land Surveyors kenOlangsurvey.com `:.5c .. ... • ,9 p c^ r— JonathanOlangsurvey.com • S _.,0,_/C. .• `\ �00� 2.0' o I hereby certify that I have surveyed the following described property: a * 49TH / O,, o LOT 2, MT. BALDY ESTATES, PHASE 1 (PLAT 2006-48) Anchorage Recording District, Alaska, and that the improvements situated thereon areat ( A ze•o. within the property lines and do not encroach onto the property adjacent thereto, Q r. Q no improvements on the property lying adjacent thereto encroach on the surveyed KENN G. • premises and that there are no roadways, transmission lines or other visible �" • o easements on sold property except as indicated hereon. Qa s 2V4511$ .• �ll % '•.LS-5202.••• 5\)p" Dated this the Day of ��f ,�,,,,�. 7-c ' at Anchorage, Alaska QO'OR0F-r- A\ �o� It is the responsibility of the owner to determine the existence of any easements, �O`\Oppo�'" covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963