Loading...
HomeMy WebLinkAboutINLET VUE ESTATES LT 4Onsite File -t t Municipality of Anchorage On-Site Water and Wastewater Program •(907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171003 PID Number: 051-021-37-000 Dwelling: ❑■ Single Family (SF) El Duplex (D) El Multiple (SF and/or D) Project: ❑I■ New El Upgrade Name: Troy Davis Home Inc. ABSORPTION FIELD Address ❑ Deep Trench El Shallow Trench [11 Bed El Mound 21363 Conley Ave El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-310-2501 4 1.2 GPO/SF 7.2 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 3.2 Ft. 4 Ft. Inlet Vue Estates 4 Fill added above original grade Gravel length Township Range Section 0.3 Ft. 50 Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 500 Fe 1 Ft. Well ' >100' 1 >100' N/A N/A >25' TANK l I Septic ❑ S.T E.P. ❑ Holding ❑Other Manufacturer Capacity Surface Water 1 >100' � >100' N/A N/A Anchorage Tank 1250 Gal. Material Number of compartments Lot Line >5' 10' N/A N/A Steel 2 NA Foundation >5' >10' , N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to D3034 Installer drainfield Northern Excavation Drainfield D3034 CO/MT D3034 Inspector Jacob Millette BENCH MARK (Assumed elevation) 100 ft Inspection ectio1. 3123117 2"" 3/23/17 Location and description 3V' 3/24/17 41h Bottom of siding at point "A" COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date i„,`P.• _AL•A *• 49T" . .. e 1,ValiZill J rll tr• ; i err Approved t,-......" --E3C--kit....1/ Date 9' -2.-E(7 0. •• .) .r•—` Inspection Report_9-1-12.doc INLET VUE ESTATES, LOT 4 PERMIT # 0SP171003 PID # 051-021-37 ALTERNATE SITE �___ '� :11\4--- HA-~-J I CO2MT2 C01 / .- T1 ---'\4. � ,___:_ i _ 2C0 SV2 �- sv, N 7 A ! Lot 3 / — — _. f 1 1� A B 1 \ \ \ FCO 2.33 32.8 ' /— WELL I SV1 29.6 44.7 SV2 37.649.5 I 2C0 40.8 . 51.8 I CO1 64.3 65.3 ` l 1 MT1 61.5 63.2 CO2 78.5 98.0 �/ Lot cJ 8 \ \ T1H#8 1 / W / 9 til 4111 TH#7 0 '�rP• ;-.-4,-- 'TA \ LEGEND *: TH it, '* TH#6 MT MONITORING TUBE FCO-FOUNDATION CLEANOUT /,f*• • TH-TEST HOLE-_ __ Benjami . iller . i .... . .92 r SV-SEPTIC VENT CO--CLEANOUT / ���; pROFESSIONA���« \ __.,„L — 15' T&E f 0 50 100 EASEMENT / .- FEETr 1"=50' l ` 1 INLET VUE ESTATES, LOT 4 PERMIT # OSP171003 PID # 051-021-37 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT: 343-7904 4700 ELMORE RD, ANCHORAGE, AK 99519-6655 WASTEWATER DISPOSAL SYSTEM OR WELL INSPECTION REPORT 0 O N 5 > 0 - - 99.2 - - - / 97.2 / INSULATION I I'-_.v 972 ��95.04 96.58 1250 GAL SEPTIC TANK v .'''".—91.24 6r= 98.3O.G. 1-0 k 1 ■ RADE 98.0 - - ...... _ -,.--_-,et/ 94.8 QRAINFIEIQROCK 'H 91.0 90.86 50' - 82.0 Q = NO GROUNDWATER 2/9/17 I- ,A:rAZ4• .9F 4) ', *: I 49TH %IV', e PROFILE AS-BUILT ��r# . '�n�uer ':� ' �� • . A' 592 .•��/ �0rlR....Sep 20.20.7 .�(� (NO SCALE) �1\��;"`==�4 Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes, Inc. Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Inlet Vue Estates Subd. Lot: 4 Block: Additional: Permit #OSP171003 ell Depth: 43 ft. From: To: Formation: Below Ground: 41 ft. 0 2 stickup Above Ground: 2 ft. 2 gravel, sand 17 38 wet silt, gravel al/Min: 25 + 38 43 gravel, water ‘tatic Level: 17 ft. asing: 43'of 6" ID Steel I iner Pipe: none •creened: none erforated: none Grouted: Bentonite De the 20 + WA tiTEI CCUALITY TESTING P � LpgolTrt��Cat1100mL Develop. Method: Air QNi`:r.3tes y rsunie —NT) 0rry L Use of Well: Residential Drilling Method: Rotary Fluids Used: none Pump Installed: none Other: none Date Drilled: 2-16-2017 Driller: Ben Mattson Development Services Department • Building Safety Division • (7•778°f`On-Site Water & Wastewater Program 4700 Elmore Road . P.O. Box 196650 K Mark Begich Anchorage, AK 99507 SA ETY Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW osP171003 Date of Issue: 1-13-2017 Parcel Identification Number: Legal Description Property Owner Name& Address: INLET VUE ESTATES SUBDIVISION LOT 4 Troy Davis Homes,Inc Conley Avenue 1689 Knik Goose Bay Rd#400 Chugiak,AK Wasilla AK 99654 Pump Installation Date: 7-19-2017 Pump Intake Depth Below Top of Well Casing: 36 feet Pump Manufacturer's Name: Goulds Pump Model: 10HS05412CL Pump Size 112 hp Pitless Adapter Burial Depth: 14 feet Pitless Adapter Manufacturer's Name: Harvard Pitless Adapter Installer: Unknown Well Disinfected Upon Completion? Yes ❑ No Method of Disinfection: Stereline Comments: Pump Installer Name: Wheaton Water Well,Inc. 1190 N.Wasilla-Fishhook Road Wasilla,AK 99654 Attention: The pump installer shall provide a pump installation log to the DSD within 3()days of pump installation. On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP171003 Tax Code Number: 05102112000 Work Type: WellSeptic Initial Permit Effective Dates: January 13, 2017 to January 13, 2018 Design Engineer: ANDERSON ENGINEERING Subdivision: T16N R1W SEC 32 Site Legal Address: T16N R1W SEC 32 LT 6 & 7 PTN G:1657 Owner/Address: EKLUTNA INC 16515 CENTERFIELD DRIVE #100 EAGLE RIVER AK 995777719 Site Mailing Address: Lot Size in Sq Ft: Total Bedrooms: This permit is for the construction of: 747490 4 Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. 003/1'1 0-011: LbcAA�c>ns ,� rb V Received Issued By MUNICIPALITY OF ANCHORAGE Community Development Department Phone: ! Development Services Division Fax: ! On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION JAN 1 n Z_';' Parcel I.D. 051-021- 1 a Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 S. Knik Goose Bay Road #400 Wasilla, AK 99654 Site address Avenue Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Inlet View, Lot 4 Lot Size -46;7644 Sq. Ft. Number of Bedrooms Four (4) 1 l I_T Y1 APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Absorption Field 0 Initial 7 Septic Tank 0 Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Private Well El Water Storage ❑ TYPE OF DWELLING: Single Family (SF) (w/wo ADU) Duplex (D) Multiple Dwellings (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 7 3 Waiver Fees: _ Date of Payment: I� /021/4' Date of Payment: jyt Receipt Number: �225 Receipt Number: Permit No. O.` pi?1UG3 Waiver No. Permit App_9-1-12.doc January 13, 2017 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 4, Inlet View Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer The owner of Lot 4, Inlet View Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or the proposed septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trenches and alternate site indicate well to poorly graded gravel (GP/GW) with minor amounts of sand and silt. The percolation rate of the soil was determined to be 1 to 5 minutes per inch. No groundwater was found in TH6 but was noted in TH7 at 19' during the placement of the test holes and none was found in either test hole during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and a 50' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3.0' below the surface and the total depth will be 7.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system is flat with only a very shallow grade to the northeast. The new trench will be constructed in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services Lot 4, Inlet View January 13, 2017 Page Two in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Benjamin Schiller, P.E. Attachments /LOT -k_- tN�LET VIEW \ SUBDIVISION 71,853 s.f. Lot 3 \ MT i / 2CO /1,250 Gallon / Septic Tank St 3s' /Tr6ct A / s� eF� � Site �CD- \ 50' Long x 5' Wide 4' Effective Depth Sv \ Absorption Trench SV / FC Four 1 I . I r• N Proposed Well 23.0 . z T SSV — Septic Vent ilit3 1 / CO — Clean Out MT — Monitor Tube \ / TH — Test Hole \ /CONTOUR INTERVAL — 2' \ LJOf \ TH7 a 1 \ N 1 ----15-' T&E ----------- -----------.. ----- -- EASEMENT \N 90'00'00-W 1128.N CONLEY AVENUE 28.18 \ Lot 5 1 No Conflicts with Wells or -Septic Systems on Neighboring /lots. All Proposed Lots ore CurFently Vacant. 1 / \SITE. -'PLAN SCALE 1' = 50' r, i LOT 4 INLET VIEW SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Pere. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Ap lication Rate) = 500 SF Absorption Area 500 SF/5 SF/LF'.5 (App. Rate) = 50 LF Trench Length THEREFORE: Construct a 50' Lang x 5' Wide x 4' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be T Below Original Ground Surface. Total Depth to be 7' Below Existing Ground. Provide T of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area. N 4'0" 5' W Natural Backfill Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock 4 TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) I- 2 3 4 5 6 7" 8 9 10- 11 12 13 14 15 16 17 18 19 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 4, INLET VIEW SUBDIVISION PERFORMED FOR: TROY DAVIS HOMES DATE: 5/9/16 PROJECT No.: PARCEL ID#: TECHNICIAN: L. BETTS TEST HOLE 7 r 0 d d a d O POORLY GRADED GRAVEL 'd. WITH SAND a GP/GW SLOPE N 0 SITE PLAN SEE SITE PLAN H i d WAS GROUND WATER ENCOUNTERED? YES d IF YES 4, WHAT DEPTH' 19 S a DEPTH OF WATER AFTER MONITORING: NONE LS 2% DA1'E OF MONI PORING: 10/15/16 P E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DWATER TH D (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 3/9 1 11:04 0.75" 2 11:34 30 9.00" 8.25" 3 11:35 0.88" 4 12:05 30 9.1911 8.3111 5 12:06 0.75" 6 12:36 30 9.00" 8.2511 PERCOLATION RATE: 3.6 (MIN/INCH) PERC. HOLE DIA. 611 (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENT'S: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/21/16 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (f«t) 1- 2 3 4 6 7 8 9 10- 11- I 1 1 1 1 1 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 4, INLET VIEW SUBDIVISION PERFORMED FOR: TRoY DAvis HOME. - DATE: 2/9/17 PROJECT No.: PARCELID#: TECHNICIAN: J. MILLETTE TEST HOLE 7A IM OB/OG d I e e a a e POORLY GRADED GRAVEL 1' WITH SAND c GP/GW SLOPE SITE PLAN SEE SITE Pu Y WAS GROUND WATER ENCOUNTERED? YES IF YES @ WHAT DEPTH? 14' DEPTH OF WATER AFTER MONITORING: 12' 2% DATE OF MONITORING: 2-16-17 DATE READING G OSS TIME MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DRO (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 2/9 1 2:28/2:38 10 7.00/1.50 5.50 2 2:39/2:49 10 7.00/1.50 5.50 3 2:50/3:00 10 7.00/1.50 5.50 4 3:01/3:11 10 7.00/1.50 5.50 5 3:12/3:22 10 7.00/1.50 5.50 6 3:23/3:33 10 7.00/1.50 5.50 PERCOLATION RATE:1 9 (MIN/INCH) PERC. HOLE DIA. 6�t (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 2/13/17 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) I- 2 3 4 5 6 7 8 9 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- PERFORMED 01T12- 13- 14- 15- 16- 17- 18- 19- SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 4, INLET VIEW SUBDIVISION PERFORMED FOR: TROY DAvls HoMEs DATE: I /9/ 6 PROJECT No.: PARCEL ID#: TECHNICIAN: L. BETTS TEST HOLE 8 OB/OG � d d c d C . d O d. POORLY GRADED GRAVEL WITH SAND GP/GW SLOPE N a SITE PLAN SEE SITE PLAN i 1 d WAS GROUND WATER ENCOUNTERED? NO d IFYES @ WHA1' DEV' 1' HI S G DEPTH OF WATER AF'I ER MONI"IORING: NONE 0 2% DATEOFMONNORING: 10/15/7016 p ° BOH @ 17' DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 3/9 1 11:17 0.6311 2 11:47 30 8.13'1 7.5011 3 11:48 0.50" 4 12:18 30 8.0011 7.50" 5 12:20 0.6311 6 12:50 30 8.1311 7.50" PERCOLATION RATE: 4.0 (MIN/INCH) PERC. HOLE DIA 611 (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 4, INLET VIEW SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 50' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 3.0' below the existing ground surface. Total depth of the trench will be 7.0' below the existing ground surface. The new absorption trench and septic tank must be placed a minimum of 100' from all private wells and any surface water in the area and 10' from the water service line proposed for the lot. A minimum of 3' of cover is required over the absorption trench and 4' of cover over the septic tank. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Building Safety Division On -Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On -Site Water and Wastewater Program. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 4, Inlet View January 7, 2017 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below the distribution line must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: Lot 4, Inlet View January 7, 2017 Page 3 of 3 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5 to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. UNMUTY OF ANCHORAGE 0 �{ Development Services Department :r Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-021-37 Expiration Date: 1. GENERAL INFORMATION Complete legal description INLET VUE ESTATES LOT 4 Location (site address) 21363 CONLEY AVENUE, CHUGIAK, AK 99567 Current property owner(s) MONTY & NANETTE MYERS Mailing address Real estate agent Day phone 21363 CONLEY AVENUE, CHUGIAK, AK 99567 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ® Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5 Waiver Fee $ Date of Payment q7/001 f Date of Payment Receipt Number % d 7,9 21 Receipt Number COSA # d SC a i 1'a 0 5 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 4/23/2021 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject toAt these various and dynamic characteristics and are outside the control of the evaluator of the •�(i well and septic system. Therefore, any estimate of how long a system will function satisfactory g�P' • . for current or future occupants or guarantee that no unseen encroachments, deficiencies or _ discrepancies exist can be given by First Water Consulting & FWfS ' *' lli '* 6. DSD SIGNATURE • '. Curtis Huffman System #1 Approved forbedrooms �c�����,.••CE128991....����/� �l FFF� -4/23/1 p���� System #2 Approved for bedrooms 11 ROFESSION Disapproved Conditional approval for bedrooms, with the following stipulations: qST,- Np m J O r-- 41, -SE Ir.FS�\\A 1�•i ;' a',1 �s By: G` ( Original Certificate Date: — 3 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X . Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other Legal Description: INLET VUE ESTATES LOT 4 Parcel ID: 051-021-37 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ® Well log is filed with Onsite (or attached) Date drilled 2/16/17 Total depth 43 ft Cased to 43 ft ® Sanitary seal is functioning correctly ® Wires are properly protected Casing height (above ground) 24+ in. Date of flow test for COSA 4/21/2021 Static water level at beginning of test 19 ft. Well production at time of test 3.8+ gpm Comments B. TANK DATA Age of tank(s) 4 years Tank type/material SEPTIC / STEEL Measured operating fluid level in septic tank 50" ® Standpipes/foundation cleanout per record drawing Date of pumping 4/19/2021 D. ABSORPTION FIELD DATA Structure served by this system Water storage tank volume NA gallons Well disinfected for coliform test? ❑ Yes ® Nc ® Coliform bacteria is Negative Nitrate 6.92 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ® Arsenic less than MRL (ND) Collected by N ES Date of Sample 4/21/2021 C. LIFT STATION ❑ Required maintenance completed Age of lift station _ years Lift station material Comments: Which system tested (date'installed) 3/23/2017 Adequacy test date 4/21/2021 ® ALL standpipes present per record drawing Results N Pass For 4 bedrooms Total measured depth from grade 7.6 ft (max) Fluid depth prior to test 0 in Measured depth to pipe invert from grade 3_6 ft (min) Water added 600 gal ❑ N/A — pressurized field New depth 0 in ® Monitor tubes go to bottom of effective. If not, state Elapsed time <1 min depth into effective ® Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate 600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: FW_, E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No Community Sewer Manhole/Cleanout > 100' ® Yes if No ft ® Yes if No Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No Absorption Field on Lot > 100' ® Yes if No ft Holding Tank > 100' ® Yes if No Neighboring Absorption Fields > 100' Water Service Line > 10' ® Yes Animal Containment > 50' ® Yes if No ® Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ® Yes if No ft ® Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No _ Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No _ Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No _ Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No —ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATIONAG a I certify that I have determined through field inspections and review ,�r Q`. • ' . of Municipal records that the above systems are in conformance ��•.. with MOA COSA guidelines in effect on this date. . TM , `. •':� • Curtis Huffman �� �Fc •. CE 128991 .• �� t) x/27/21. •���� PROFESSION,,�� ft ft ft ft ft ft ft ft www.muni.org/onsite Nitrate Advisory Certificate of On -Site Systems Approval # OSC211205 Subdivision: Inlet Vue Estates Lot 4 A water sample revealed a nitrate concentration of 6.92 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening, or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. r ' 7 9 •, Municipality of An ho ,n e+ r On-Site Water and Wastewater Pro ra $EP 9 zu.,r (907) 343-7904 a SA ETV ti teA Cu Certificate of On-Site Systems Ap sol 6 s I-(,) Parcel I.D. 051-021-37-000 Expiration Date: I ^ 7 1. GENERAL INFORMATION Complete legal description Inlet Vue Estates Lot 4 Location (site address) 21363 Conley Ave Current Property owner(s) Troy Davis Home Inc. Day phone 907-310-2501 Mailing address 1689 Knik Goose Bay Rd Ste 440 Wasilla, AK 99654 Real Estate Agent Day phone 2. TYPE OF DWELLING: O Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received Date: cl IDIDI I/ COSA to be released to the en in er,unless otherwise requested by the engineer. COSA Fee $ l n. 60' Waiver Fee $ Date of Payment q/42DIn Date of Payment Receipt Number Qq t{ J /C Receipt Number COSA# 615C-n, f t/39 Waiver# 5. STATEMENT OF INSPECTIO 8Y ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave. Suite 203 Engineer's Printed Name Benjamin Schiller Date 9/11/17 4e44e 6. DSD SIGNATURE �• 4�9 TN a ;w4� •.0,1 44444 Iltpl `IJ/- System#1 Approved for �(( bedrooms 0 , 0'3, : ry1 r �°•, System#2 Approved for bedrooms f.', • • 44' Disapproved ,� - .••9(;t�+ !7.••a 0tyip tea. Conditional approval for bedrooms, with the following stipulati5r ,SCIS 01;r. Original Certificate Date: at - 17 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet [ '. c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description Inlet Vue Estates Lot 4 Parcel ID: 051-021-37-000 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 2116117 Sanitary seal (Y/N) Y Wires properly protected (YIN) Y Total depth 43 ft. Cased to 43 ft. Casing height (above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 2/16/17 Static water level 17 ft. ft Well production 25+ g.p.m. g p m. WATER SAMPLE RESULTS: Coliform ND colonies/100 mL Nitrate 0.440 mg/L Arsenic ND ug/L Date of sample. 7!19/17 Collected by: Wheaton Water Wells B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 3124117 Tank size 1 250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N/A Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA Date installed 3/23/17 1.2 Soil rating (g.p.d./ft2 or ft2/bdrm) GPD/SF System type 5 Wide Length 50 ft. Width 5 ft. Gravel below pipe 4 ft Total depth 7.5 ft. Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For 4 bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100On adjacent lots >100' Absorption field on lot >100On adjacent lots 100 Public sewer main '75' Public sewer manhole/cleanout >100 Sewer/septic service line '25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100 SEPTIC/HOLDING TANK ON LOT TO: >5' >5' >5' Building foundation Property line Absorption field >10' Water main Water service line '1 >100' Surface water Wells on adjacent lots >100 ABSORPTION FIELD ON LOT TO: Property line >1Building foundation '10 Water main '1 Water Service line >100 Surface water '100 Driveway, parking/vehicle storage '1 Curtain drain None Noted Wells on adjacent lots >100� F. COMMENTS jetG. ENGINEER'S CERTIFICATION �f � I certify that l have determined through field inspections and I'ti.• ••••'f-�. review of Municipal records that the above systems are in • 9THt... 9 �� conformance with MOA COSA guidelines in effect on this date. ....:.�� Benjamin Schiller • : zr,y0 Engineer's Printed Name S f Date 9/11/17 X41, CE•. � OQip�t* EISKY1f ,oa COSA brown sheet 10-10-12.doc Tract A N 85'30'00"E 81.36' o \ oSSB.. 719 SEPTIC PIPES 01 ----jowl --......,, / 1100.1.11111 >.4'. in 7.1• 1 4o RP �,k5�•-1 .. . ... ';. s,EeUNE -`fQ2 / • -- - At Lot 3 0 GRAVEL . `o f cv DRIVEWAY * • WELL V' NI o \ • o Lot 5 �, HOUSE DETAIL z o / SCALE: 1-=40' c \ 10 0, CIEC,K 35.0 b25-0 N Lot 4 _ . 1.3,14.5 O O 71,853 s.f. N 253 37..•C� 0 5.0 " 25.5' /2.p• r, o0 • „�� o . C.3� "' v 15' T&E /4 S o EASEMENT • N 2,,5. — — — N 90'00'00"W 128.40' 0 - —CONLEY AVENUE PLOT PLAN AS BUILT _x SCALE 1" = 60__ GRID NW 1657 Project No. 16-379/66 11500 Uaryl Avenue, Anchorage. Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone 4pO4p4 ke(9nOlangsurve com7) 522-4625 ax ��OF ry \;%, Professional Land Surveyors y C - q p JonathanOlangsurvey.com , Q I hereby certify that I have surveyed the following described property: OooP . �) •�uv LOT 4, INLET VUE ESTATES SUBDIVISION (PLAT 2017-6) 4 TH /\ .. *Qa Anchorage Recording District. Alaska, and that the improvements situated thereon are Q 4 within the property lines and do not encroach onto the property adjacent thereto, that 0 Q no improvements on the properly lying adjacent thereto encroach on the surveyed 4' KENN LAN o premises and that there are no roadways, transmission lines or other visible VVV �, p easements on said property except as Indicated hereon. 4� �s ` ly7 / 4Vez) •.LS-5202.••' SJo7 Dated this the ';-'-- Day of Yrt5"•-'i»— . .L-°\'-1 , at Anchorage, Alaska ,,o '' ••' 4 4 ROPFSSIONA� It is the responsibility of the owner to determine the existence of any easements, °�4`,OQp�b covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963