Loading...
HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 2CI¢X L MUNICIPALITY OF ANCHORAGE · DMSION OF ~qVIRONMF2YrAL HEALTH DEPAKrME~£ OF HEALTH AND ~%riRONMENTAL PROTECTION APPLICATION FOR HEALTH AUI'HORITY APPRQVAL CERTIFICATE 1. General Info~'n~tion Application Date June (a) Legal Description (include lot, blcck, subdivisic~l, section, township, range) Lot 20, Ea~le River Valley Ranchettes Locati6h (addressordirections) 146 Citation Road, .Eagle River, AK 99577, (b) (c) Applicants. Nam~ Start Sorenson Telephone 694-2882 Applicants Address 146 Citation Road, Eagle River, AK 99577 Applicant is (check ors) Lending Institution Buyer ~; Other ~ (explain); (d) Lending' instituticn ]~/A . T~ lephone Address (e) Real Estate Co. & Agent ~q/A .. Address Telephone 2..Type of Residence. Single-Family ~ Number cf Bedrccms 3. Wate-" Supply e ~,lti-Family ~ Other (describe) Individual Well ~-~ C~.~,~nit!; ~ Public ~ Ncte: If community ~11 system, must ha%~ written ccnfirmaticn fron the State Dep~t~ent of Envirc~'~rmntal Conservation attesting to the legality and status. Es .the ~11 adequate for the number of bedrooms specified in this Hk~ (Y/N) N/A Se wa.~e Disposal Onsite ~-~ Public ~-~ Cc~Nrunity I.. i Holding Tank ~-~ Is tb~wasteWater disposal system adequate fcr *_he rnmber of ~dro~ns (Y/N) y~ [Pa~e 1 of 2] 2-15-84 5. Engineerinq Firm Providin~ ,Inspections, Tests, Data and Information I ~rtify that I have checked, verified, cr confounded to all M3A HAA Guidelir~s in effect on the ~ate of this 6~ 1984 Name of Firm:nE tech Engineers, Inc. 694-3574 Telephcme Address 13 LeDoux, Eagle River, AK 99577 Signed by Vernon L. Roelfs, PE Date.._ June 6. 1984 (ENGiNEER SEAL) 6 .,DHEP Approval Appro~d for ~ bedrcQ~ Approved ~ Disapp~o~d ~ Terms of Conditional Approval The Municipality of Anchorage Department of Health and' Envirc~Tental Protection dces not guarantee the continued satisfactory perfQrmanee of the water supply and/cr t~he wastewater disposal system. This approval indicates that, as of the validation date shown above, based ex1 tt~ data and information furnished by an er~3ineer registered in the State of Alaska, the water supply and wastewater disposal system is safe and func ticr. al for the rzumber of bedrooms and type of structure indicated. 7.'Mail the HAA to the following address: 146 Citation Road River, AK 99577 KB2/d5/s [Page 2 of 2) 2-15-84 A® /,,,~UNIClPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTIOI',J MUNICIPALITY OF ANCHORAGE (MOA) HFALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Legal Description: JUII 2 2 1984 .RECEi.VEI Sorenson Lot 2Ct Eagle River Valley Ranchettes Well Classification Community Well Lo~ P~esent (Y/N) N/A · Total Dspth N/A Static Weter I~l N/A Casing Hsight Abo~ Ground Cased to N/A If A, B, ce C, D.E.C. ApprOVed(Y/N) Yes Date Ca~pleted N/A Yield N/A N/A Depth of G~outirg N/A Pump Set At N/A Sanitary 'Seal on Casing (Y/N)w/~, Electrical Wirin~ in Conduit (Y/N) Separation Distan~ss f~cm Well: To Septic/HoldinG Tank cn Lot 200' + To Nearest EdGe of Absorption Field c~ Lot TO Nearest Public Sewer Line N/A C leancut/Manhole Wate~ Sample Collected By N/A Water Sample Test l~sults N/A Da~-ession Around Wellhead (Y/N)N/A ; On Adjoining Lots 200' + 200' + ; On AdjoininG Lots 200' + To Neeeest Public Sewer To Nearest Sewer Service Line on Lot 200' + ~ Date N/A SEPTIC/HOLDING TANK II%TA Dste Installed lJnknnwn Size 1/~/7{7 ~ml No. of C(~a~t2r~n~s ~ Standpipss (Y/N) Yes Air-tight Caps '(Y/N) ¥.s Foundation Cleanout (Y/N) Nn ~ DsUression o~sr Tank (Y/N) No Date Last Pumped 4-21-84 lam~pirg/Maintenance Contzact on File (Y/N)~ N/A ~ fac N/A HoldinG Tank High-Water Alam~ (Y/N) N/A Tempceaey Holding Tank Permit (Y/N) N/A Sepa~ation Distano~s f~cm Septic/Holdir~3 Tank: To Wete~-Supply W~ll 200' + To l~operty Line 35' To Water Main/service Line 30' Course N/A To BuildinG Foundation 5' To Disposal Field 20' To Stream, Pond, Lake, ce Major' D~ainage Comnsnts [Page 1 of 2] 2-15-84 C. ABSORPTION FIELD [I%TA Soils Rating in Absorption Strata Date Installed Unknown Width of Field Unknown Squa=e Feet of Absorption Area Unknown Dap=essic~. over Field .(Y/N) No Date of Last Adequacy Test Results cf Last ~4equacy ~est 540 ~pd ~ Separation Distance frcm Absc~ption Field: To Water-Supply Wall 200' + To P~operty Line 15' Unknown Type of System Design Crib Length of Field Unknow~ Depth of Field _.. 7,?' Gravel Bed Thickness Unknown Standpipes Present (Y/N) Yes 5-22-84 To Building Foundation ?B' To Existing or Abandoned System cn Lot 29' ~ ; On Adjoining Lots 10Q' + To Water MaiP/Service Line ~0' ~ To Cutbank(if present) To Stream/Pond/Lake/~'Majo~ Drair~ge Ccurse N/A To D~iveway, Parkirg Area, or Vehicle Stcrage A~ea 4~' C~,,~=nts There appears to be an abandoned system on the lot. No ~ - - '..."--- I ~ I - /. ," - ' LIFT STATION - ~ ~. Siz~ in Gallons "Pump On" isvel at High Water Alarm Level at Tested for Electrical Codes(Y/N) Manhole/A~ss (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles du~ing Adequacy Test. M~ets ~DA ** ** Check Permitted Bedrocm Rating Against HAA Request I' certify that I have checked, verified, c~ conformed to all MOA HAA Guidelines in effect on t.he date of this inspection. Ccmpany Entech Engineer'S, Inc. 2-15-84 TECH ENGINEERS, INC. CIVIL · SANITARY June 5, 1984 Municipality of Anchorage Department of Health & Environmental Protection 825 "L" Street Anchorage, AK 99501 Re: Sorenson Health Authority Approval Application; Lot 2C, Eagle River Valley Ranchettes Dear Sir, During the period from May 26 to May 29, 1984, we performed research, investigations and testing persuant to Health Authority Approval on the above referenced lot. The property is served by an approved public.yater system (see attached letter from DEC). We performed an adequacy test on the septic absorption system and found that it absorbed at the rate of 540 gallons per day (gpd). This is more than the 450 gpd required, and the system is adequate. The septic tank was pumped as part of the test and the tank volume was verified to be 1000 gallons. To our knowledge, we have assembled all available information on the HAA Checklist and Application Form. We were unable to locate an Inspection Report for the sewage disposal system. We found the system to be a 1000 gallon septic tank with a crib for effluent disposal. We offer this information for your review. call if you have any questions. Please · -..~ oF 4, -%', cc Stan Sorenson Attachments x ioa ion ~ Checklist 33 LE DOUX LANE · EAGLE RIVER, ALASKA 99577 · TELEPHONE~OT) 694-3574