HomeMy WebLinkAboutVERN HAIK LT 6V rn Haik Lot 6 #051-061-84 MM~M Contracting P.O. Box 670495 Chugiak, AK 99567 P~e: 688-1236 T~ree Municipality of Anchorage Page 1 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 o Anchorage, Alaska 99519-6650 o Telephone: 3434744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW000192 PlO Number:_ 051 -061 -84 Wastewater System: · ~ New [] Upgrade ABSORPTION FIELD Deep Trench E] Shallow Trench [] Bed O Mound [3 Other 11 . 8 GPD/S~. Ft. LOt: 6 Block: Vern HaiL 4 TOWnShip: t Range: I Section: ~]1 added above origln~ll grade: Grave] lengm: WELL: .-.. [] New [] upgrade . -.. I 3 Clas~ific~t,o, ( Pri~ate. A.B.C): TO~I ~pm: Case TO: Io~l absorption¢~ p,~ materbl: class A PWS Ft. Ft. ' SO. Ft. D3034 PVC grilteE - ?. MM&M Wel~ N/A LEGAL DESCRIPTION Surfaoe - .Water Lot Line Foundation ~nchora( ~-·Tank Two - LIFT STATION -_ Orain '!.~m~rks: Insulation Over Tank. BENCH MARK " Top'.of Front Deck.-. '...- ..... . .: . t00.'0 Inspections performed by:. MEA ' ' · : Date~: 1st 8/2 / 00" · ' 2nd 8/3/00 Department of Health and Human Services.approval ' ' Reviewed and approved by:~ ifA/' 'ff4::;2¢.~ Date:'~ '~L'~:tgi0 · - .-: ..:.';3 -. · : .-/ : '. : '-. ',- -... Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 - Anchorage, AK 99519-6650 - 343-4744 on-Site WasteWater Disposal System or Well InsPection Report Permit Number SW000192 Page 2 of 3 PID No. 051-061-84 DAWN LANE / / Ii 15' Utility Easement ~TH2 Alternate Site C ~ ~ 4 C3 . __ Home ~-~J S1 Water Service O Z O A B- C S1 9.8 21.4 · S2 7.1 27.1 - C4 21.5 78.3 C5 28.8 ~ 39.2 M1 17.4 68.5 PLAN AS-BUILT SCALE 1" = 30'" Page 3 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,0. Box 196650 - Anchorage, AK 99519-6650 - 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW000192 PID No. 051-061-84 $ I / I ~1,ooo o /o / /n-~ 4~allon ~4°/~/~/;~-~ e p. Tan 94.0 98.5 / Geotextile Fabric Drainfield Rock 86.9 80.0 32' ' PROFILE AS'BUILT ~,94.0 MEMORANDUM DATE: September 29, 2000 TO: FRO~: Dan Roth/Jeff Poet Mike Anderson, P.E. SUBJECT: Lot 6, Vern Haik Subdivision Certificate of Health Authority Approval Separation Distance to 25% Slope I again inspebted the final grading over the absorption trench on Lot 6, Veto Haik Subdivision on September 28, 2000. The contractor was on site and had recently completed additional grading on the final ground slope immediately north of the trench. The intent was to achieve a proper set back distance from the final ground slope to the edge of the new trench. The easterly 30' of the trench is of no concern as the finished ground slope is less than 25% and no separation requirements are necessary. The finished slope at the westerly end of the trench however is at or slightly steeper than 25%. An elevation was taken at the finished elevation on the edge of the trench and another at 35' to the north. The difference was found to be -9.3' which equates to a 27% slope or slightly greater than the 25% allowed. The slope when extended from 2' above the distribution pipe at a 25% grade descends to an elevation of-10.25', which is below the ground surface at this point. In summary, the 25% slope when extended downward from 2' above the distribution pipe at the edge of the trench will not intersect existing ground. No further grading is therefore necessary and the septic system is acceptable for certification. ANDERSON ENGINEERING P.O. Box 240773 ANCHORAGE, AK 99524 (907) 522-7773 Cell (907) 441-4000 JoB Lot 6, Vern Haik Subdivision SHE~ NO OF MEA 9/29/00 CHECKED 8Y DATE SCALE Horiz. 1 "=10 ' Vert. 1 "=3 ' MEMORANDUM DATE: September 20, 2000 TO: FROM: Jeff Poet Mike Anderson, P.E.'~~ SUBJECT: Lot 6, Vern Haik Subdivision Certificate of Health Authority A'pproval Attached is a copy of the Soils Log for Test Hole No. 3 completed during the construction of the absorption trench on Lot 6, Vern Haik Subdivision. The soils encountered in this test hole were identical to those encountered in Test Hole No. 1 with a percolation rate of 15 minutes per inch. Please et me know if additional information is required prior to the issuance of the Certificate of Health Authority Approval for this. lot. Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: MM&M Contracting Legal Description: Lot 6, Vern Haik Subdivision ~LOPE OG/OL Test Hole No. 3 Date Performed: t SITE PLAN See System Site Plan 1 11 12 13 14 15 16 17 18 21 Silty Sand w/Gravel SM Was Groundwater Encountered? No S If Yes, What Depth? L Depth to Water O After Monitoring P Date: E Bottom of Hole Reading Date Gross Net Depth To Net Time Time Water Drop · Perc. Rate: 15 Min./In. Perc. Hole Diameter: Test Run Between: Comments: Soil Material is Identical to That Encountered in Test Hole No. 1. Performed By: Tim Kimbrough 1, i h I E. Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 6/14/00 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONiSITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jun 23, 2000 Expiration Date: Jun 23, 2001 Permit Number: SW000192 Legal Description: VERN HAIK LT 6 Design Engineer: 0014Anderson Engineering Owner Name: MM&M Contracting Owner Address: PO Box 670495 Chugiak, AK 99567- ParcellD: 051-061-84 Site Address: Lot Size: 24731 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: ~ Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must nofif~ DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: June 14, 2000 Municipality of Anchorage Department of Health and Human Services 825 "F" Street Anchorage, AK 99502-0650 Subject: Lot 6, Vern Haik Subdivision Septic System Design and Permit Application Impacts to Adjacent Pro oerties Dear Onsite Services Engineer: The owner of Lot 6, Vern Haik Subdivision intends to construct a three-bedroom home on the lot. We are hereby requesting a permit be issued to construct a septic system on the property to serve the house. The attached Site Plan and backup documentation identify the location and configuration of the new system and alternate site. I! also provides details as to the soils conditions and percolation rates in the area of placement for the septic system The subdivision is currently served by a community water system and no conflicts exist between the new septic system and water service lines in the area Two test holes were placed on the lot to determine the Subsurface soil characteristics. Both holes were similar and revealed silty sand material with some gravel. The percolation rate varied from 5 to 15 minutes per inch. The system is designed for the slower rate of 15 minutes per inch. No groundwater was encountered during the placement of the test holes and none was noted during the ensuing monitoring period We have therefore designed a deep trench system wi!h 7' of dra n field rock beneath the distribution piping. 'The piping will be placed at 3.5 below the surface and the tota depth Of the new trench will be 10.5'. A minimum of 3' of cover will be provided over the trench and 4' over the septic tank. The groune surface on the lot slopes from east to west at gradual and varying slopes up to the mid point of the lot where it slopes much more dramatically. The new system will be constructed in an area where the slope is fairly flat. The absorption trench wil be placed parallel to the contour lines in the area and at least 50' l'rom any break in grade greater than 25%. If the system is 'constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no aaverse impact on the wells in [he area or those to be constructed in the future. The subdivision is currently served by a community water system Eot 6, Vern Haik Subdivision June 14, 2000 Page Two The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as desigr~ed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area The system, if constructed as designed, will have no adverse impact on drainage patterns in ti~e area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments III THIS 59o52,35,, Access ',asement 7 AREA MAP SCALE 1" = 100' N89°55'26 I t C r DAWN LANE 10' utility Easement 3' 41' Lonq x x 7' Elf. Depth Absorption Trench Bluff Area ~oTH1 Alte Site 0% l%r SITE PLAN SCALE1"=30' NOTE: Lot Is Served By A Community Water System. No Conflicts Between Tank and Water Services or Mains in the Area. hate 0 Z 0 LOT 6, VERN HAIK SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Perc. Rate: 15 Min./Inch Application Rate: .8 GPD/SF Deep Trench System 1,000 Gallon Septic 7' Drainfield Rock Tank 3 Bedrooms X 150 GPD / .8 GPD/SF = 562.5 SF of Absorption Area 562.5 SF/14 SF/ LF of Trench = 40.2 LF Trench Length Therefore: Construct a Deep Absorption Trench System With One Lateral 4 1 ' in Length with 7' of Drainfield Rock Beneath the Distribution Pipe. Distribution Pipe in Trench Placed at 3.5' Below the Original Ground Surface. Total Depth to be 10.5' From Original Ground Surface. Insulate or Mound Over Trench to Provide a Minimum of 3' of Cover. 6'; Backfill 3' __Geotextile Fabric 4" Perforated PVC (Slots Down) ~Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Provide 3' Cover Over Trench and 4' Over Tank or Insulate. Maintain 10' Separation From Lot Line, Maintain 10' Separation From Water Service Line. Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: MM&M Contracting Legal Description: Lot 6, Veto Haik Subdivision ;LOPE OG/OL Test Hole No. 1 Date Performed SITE PLAN See System Site Plan 1 11 12 13 14 15 16 17 18 21 Silty Sand w/Gravel SM Bottom of Test Hole Was Groundwater Encountered? No If Yes, What Depth? Depth to Water After Monitoring None P Date: 6/14/00 E Reading Date Gross Net Depth To Net Time ~Time Water Drop 1 6-Jun 9:00 2" 2 9:20 30 4" 2" 3 9:21 1.75" 4 9:51 30 3.75" 2" 5 9:52 2" 6 10:22 30 4" 2" Perc. Rate: 15 Min./In. Per,c. Hole Diameter: 8" Test Run Between: 6' and 7' Comments: Test Hole Presoaked Prior to Percolation Test. Performed By: Tim Kimbrough I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 6/14/00 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: MM&M Contracting Legal Description: Lot 6, Vern Haik Subdivision OG/OL Test Hole No. 2 5 6 7 ;LOPE Date Perforrr CITE PLAN See System Site Plan 8 9 10 11 Silty Sand w/Gravel SM Was Groundwater Encountered? No S If Yes, What Depth? L Depth to Water O After Monitoring None P Date: 6114100 E 12 13 14 15 16 17 18 21 ' Bottom of Test Hole Reading Date Gross Net Depth To Net Time Time Water Drop 1 6-Jun 8:50 2" 2 9:20 30 8" 6" 3 9:21 1.75" 4 9:51 30 7.75" 6" 5 9:52 2" 6 10:22 30 8" 6" Perc. Rate:5 Min,/In. Perc. Hole Diameter: 8" Test Run Between: 6' and 7' Comments: Test Hole Presoaked Prior to Percolation Test. Performed By: Tim Kimbrough I, Michael E. Anderson Certify That This Test Was Perfo~ in Accordance With All State and Municipal Guidelines In Effect On This Date: 6/14/00 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 6, VERN HAIK SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,000 gallon septic tank at the location shown on the Site Plan. It also includes the construction of a new 41' long x 3' wide x 7' effective depth absorption trench. The total depth of the trench shall be 10.5' below the existing ground surface. In addition, the trench must be placed a minimum of 50' from any break in grade greater than 25%. A minimum of 3' of ground cover is required over the trench and 4' over the septic tank to prevent freezing. Direct bury insulation may be placed to reduce the amount of protective cover. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all appiicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. The new 1,000 gallon septic tank must be procured from an approved source and installed at the location shown on the plans. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. , 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. Lot 6, Vern Haik Subdivision June 14, 2000 Page 2 of 3 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. A silt barrier or geotextile fabric must be placed between the drainfietd rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting s0il is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall 'be fitted with watertight couplings (Caulder, Fernco, or equal). Lot 6, Vern Haik Subdivision June 14, 2000 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes; cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. COSA to be released to the engineer, unless otherwise requested by the engineer COSA Fee $V1Jaiver Fee $ Date of Payment 191961426 96 Date of Payment Receipt Number CjieReceipt Number COSA # .: 0 �yC' �otl D9 ... Waiver # i ,. ,- .. Y•' ,..;r..-.. �9.'. �'-. , 'Ch ,<!i2iLLr .-'3�:5. k..'G7{�wdv"�:.i�tY:fv`ikl@htl'i-.?rF,i.t,M,,.,i l:'•::31'•ii': ..�:_�. `'�, L. ....si7.-,.:ACiF..G,. 5. STATEMENT OF INSPECTIONBYENGINEER As certified by my seal affixed hereto and as of the validation date shown pelow, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval'Cuidelines for this application., -shows that the on-site ,water supply and/or wastewater disposal system. is (are), safe, functional and adequate. for the number of bedrooms and type of structure indicated herein. I furthef:4 enfy'th'ai" used-ofa the- -information • obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are),.in compliance with all applicable Municipal- and State• codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site. to verify the information:submitted. Name of Firm Crewdson Engineering LLC Phone 907-280-9493 x020: System #1 Approved for ,3 bedrdloms ' System #� Approvec>l for bedrooms Disapproved Conditional approval -for ' '"bedrooms;'inith the`foltovuing stiputatior���� ,. ,. .` r'f, t. ., . t: ... ', Fv!tlC 1 ,:7; .)). !}i.- ..r. .,... ,j", :•s,)+i7?.rC- ..! . of ti,.. ,,`, 4. By: ---- Original Certificate Date: 3 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given In ara ra h 5 an Inde endent rofessional cliril'ert Int erre" isteried In thd'State of Algike" l'"unici alit of Anchorage is 9 P 9 p Y P P 9 9 P Y _ 9 not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: _..-....... ... COSA Checklist . X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory .... Uther ...._ ...r COSA Checklist blue sheet ' l . F COSA Checklist Legal Description: Vern Haik Lot 6 Parcel ID: 051-061-84 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. urcI Public Water System #211431 Comments B. TANK DATA C. LIFT STATION Age of tank(s) 19.8 years ❑ Required::maintenance,completed Tank type/material Steel Age of lift station years Measured operating fluid level in septic tank 49° Lift station material ❑ Standpipes/foundatfon c(eabout per record drawing Comments: Date of pumping 4/20/2019 D. ABSORPTION FIELD DATA Which system tested (date installed) 8/3/00 Adequacy test date 3/12/20 ❑ ALL standpipes present per record drawing Results M Pass For 3 bedrooms Total measured depth from grade 11.3 ft (max) Fluid depth prior to test 18* in Measured depth to pipe invert from grade 4.3 ft (min) Water added 450+ gal ❑ N/A — pressurized field 24* New depth in ❑ Monitor tubes go to bottom of effective. If not, state- 75 depth into effective Elapsed time min ❑ Code -required soil cover over field Final fluid depth 19* in ❑ System presoaked Absorption rate `450+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) No date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencieslincludes approximately 18" of sludge in bottom of monitor tube COSA Checklist yellow sheet E. SEPARATION DISTANCES elle: (Please enter distances if less than required or if community well) Public Water System #211431 From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No 5+* ft Surface Water > 100' Yes if No ft Property Line > 5'Q Yes if No ft Wells on'Adjacent Lots: Absorption Field > 5' Yes if No ft Private Wells ,> 100' „- M✓ Yes .]f` No Water Main > 10' ` Yes if No ft Community Wells > 200' ✓V Yes if iso ft.. Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field 66 C'ot to (please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway- comment below Property Line > 10' Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' U Yes if No ft Water Service Line > 10' F/ Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100'✓Q Yes if No ft F. ENGINEER'S COMMENTS per inspection report approved on 9/29/2000 „r. 0f A4 Xis G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review / * ' H .*I • of Municipal records that the.above systems are in conformance with' MOA COSA l ' guidelines in effect on this date. p Jarr3 p i cii COSA Checklist yellow sheet Municipality of Anchorage Development Services Depsrtment Building Safe~ Division On-Site Water & Wastewater Program 4700 Elmore Road P.O, Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEHS APPROVAL FOR A SINGLE FAHILY DWELLING Parcel I.D. 051-061-84 1. GENERAL INFORMATION Expiration Date: Z'- / 7- /¢'~ Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address VERN HAIK LOT 6 24738 CHUGIAK DRIVE *CHUGIAK , AK 99567 CHARLES MIESLER Day phone 24758 CHUGIAK DRIVE *CHUGIAK ~ AK 99567 Day phone c/o AGENT GORDON SLOANE W/ REMAX Day phone 110 W. 38TH AVE. *ANCHORAGE, AK 99503 244-3381 Unless other~ls.e requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class A Well · Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a pedod of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. STATEMENT OF iNSPECTiON BY ENG N~ER c~luxeu~ eLo aS ~,~ ,.i¢e Vc~nuc~uO~i As cer~/fied by my seat ~'-~' ~ .... and ×,,~ .~,.,~,, _ date shown be/ow, I verify,i,~ ...... ,,,y investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this appfication, shows th.2t the on-s/re ~4~,'.er supp!y ~nd/or ,.,.~ste~ter dispose! system, is (~re) safe, functiona! and ~o'equ~te for the number of bedrooms and type of structure indicated herein. I fu~her verify that based on the IR; .F.~,-~ ;~,a.,~o~~,,,~'~t~*~i~"l ,¢ro,~,, .,,~¢'/~~,~,4 .-~ i,-. b-~ ~..~h~yl¢-~,~'F/~'~R'~r~"'~~,,,~,,~,~ .,~il~ ~,,~ ,-~ ,.,/,, ~,,, .Fr-,,~ ~ ,,,.~/', ' ' ~-',.-¢~'~, ,[~w'c"~'f~/w~¢'i'~'~ a,~H,,~ "'~t-'~'~' ',i~e ,-~,'-fi,"~ r~ .,,~f~z~ on-site water supply and/or wastewater disposal system is(are) in compliance with afl appficab!e Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 357-6179 Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date ~/¢(=,//¢ Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidefines & Regulations. The reported results described the performance of the · system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of afl wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for t,he sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE ~"/'Approved for' 3 Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory' Well Flow Adviso~ Nitrate Advisory ArssRic ^ ~' ': Maintenance Agreements Supplemental Engineer's Report Original Certificate Date: ~ - / 7 -// Municipality of Anchorage ....... Development Services Department Building Safety Division < ' " On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: VERN HAIK LOT 6 Parcel ID: 051-061-84 A. WELL DATA Well type A If A, B, or C provide PWSID# 211431 Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N)_,.--""'"' Total depth ft. Cased to ft. Casing height ~d) in. FROM WELL LOG AT INSPECTION Date of test ~_ Static water level ~ _ .ft. Well production _...--~ g.p.m. _ g.p.m. WATER SAMPLE R~8~~~. Coliform _..---~colonies/lO0 mi. Nitrate mg./L. Collected by: ~ ug./L. Date of sample: SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tanksize 1000 gal. Number of Compartments 2 Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO Date installed 8/2/00 Cleanouts (Y/N) YES High water alarm (Y/N) N/A Date of pumping gl/3 o/10 ' / ABSORPTION FIELD DATA Date installed 8/3/oo Length 41 ft. I'BELOW EXISTING ORADEI Soil rating (g.p.d./ft2o~ 0,8 Width 3-5 ft. Total depth '11.58 ft. Eft. absorption area 574 ft2 Monitoring tube YES Date of adequacy test 8/10/11 Results (Pass/Fail) PASS Fluid depth in absorption field before test 22 in. Water added 1217gal. Elapsed Time: 0 min. Final fluid depth 22 in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN TRENCH System type DEEP Gravel below pipe 7 .ft. Depression over field NO For 3 bedrooms New depth 22 in. 450+ g.p.d. If yes, give date - D. LIFT STATION Date installed "Pump on" level at Size in gallons Manhole/Access in. "Pump off" leveL--High water alarm level at Cycles tested. in. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Meets alarm & circuit requirements? COMMUNITY WATER On adjacent lots On adjacent lots _.-.-~ .P_ubtic-s~wer manhole/cleanout Public sewer main ~ Sewer/septic serv~ -----~, Holding tank ~nt areas, storage areas Manure/animal excrete SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water. 100'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line '10'+ Building foundation 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots. 200'+ Water main N/A Driveway, parking/vehicle storage 10'+ F. COMMENTS *ASSUMED PER AS-BUILT SURVEY-C/O IS VERY G. ENGINEER'S CERTIFICATION ! certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date ~ /I/o /l/ CLOSE TO 10' SETBACK. COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number 8251K DAWN LANE LOT 5 N89°52'35"E 125.63 15' Elec. & Telecomm. ~ Easement LOT 6 ~ 33 ? \ - I/ I o Gravel ddveway C°nc' b'°ck re" I ~1 ~ ~ z -,- ~ ~Sto~FZHouse:[ '~ Z = SCAL~: 1"=40' 62.0 J- ~onc. block ret wall [ ' chain link fence (~p) :~ 33 . LOT 7 ~ OF AL~), I hereby~at Ihave ~do~d a MoAga~e'sins~o% ~. · .... '~"- J~ '-~ ~ VERN HAIK SUBDIVISION 2.."49TH~ '".~ ~ ...... ~ .......... _~/~' ~ improvemen~ situated ~ereon am ~i. ~e prope~ lines rrea wala[Ka ~ ~ ro n ..'~' adja~t ~ereto, ~at no impmvemems ~ ~e p ~ ~ g ¢ffO~ ...... "~ ~ ~ ws[ble easemen~ on said pro~ ex.pt as ~nd~t~ Dated at Anchorage, Alaska this 28th .day of March ,2008 EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED FRED WALATKA & ASSOCIATES PLAT ARE NOT SHOWN HEREON. FB 08-2, pg 15-16 Engineers and Surveyors BE (907-248-1666) Municipality o.f Anchorage Development Servtces Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.a nchorage.ak.us (9O7) 343-79O4 CERTiFiCATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-06t-84 Expiration Date: ...5"--- '7- O ~ 1. GENERAL INFORMATION Complete legal description Lot 6~ Veto Haik Subdivision Location (site address or directions) 24738 Chu,qiak Ddve Current Property owner(s) Geor,qe and Dawn Haynes Mailing address 24738 Chuqiak Drive Chu,qiak~ AK 99567 Lending agency Day phone 265-2758 Day phone Mailing address Real Estate Agent Lynn Swanson Day phone 689-6464 Mailing Address '16635 Centerfield Drive Ea,qle River~ AK 99577 Unless otherwise requested, HAA will be held by DSD forpickup. 2. NUMBER OF BEDROOMS: Three (3) 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class A_.. Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individ,u, al On-site [] Individual Holding tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Development Services Depadment (DSD) Issues Cedificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of titJe (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) CedJficates are valid for one year for properties served by Class A or B wells or a public water system. The MunicipaIity of Anchorage is not responsible for errors or omissions in the professional engineer's work. Legal Desczipt]on: WELL DATA Wee type ;;ass A Data completed Total depth Date of test Municipality of Anchorage Development Services Department Building Safety Division 'On-Site Water & Wastewafer Program 4700 South Bragaw St. P.O. Box 196650 Anclxxage, AK 99519-6650 www.cLanchomge.ak.us (Sm3 343-79O4 HEALTH AUTHORITY APPROVAL CHECKLIST Lot 6, Vem Halk ~_,~ ~h,~dslon Parcel ID: 051-~61.84 ~f k e, er c provide PWStO #~'5'2 t- £,~-OA~e~ Log (Y/N) San~,ry sea~ (Y/N) W~.as prepe~y pmtactad (Y/N) Cased ta __lt. Casing height (above ground) FROM WELL LOG AT INSPECTION Static water level weu producflun WATER SAMPLE RESULTS: Date of saml:de: SEPRC/HOLDING TANK DATA Tank Type/Material ~e~d~teel Tank~ze '1,~00 gal. FoundaUon deanout (Y/N) Y_ Date of pumping ABSORPTION FIELD DATA Date installed ~r2000 Length 4t Tot~ depth 11 fl. Data of adequacy test g.p.m, g.p,m. Numb~ of Compartments _2 Depression aver tan~ (Y/N) N Pumper ~ Pumping C4eanouts Om) Y High water alan~ O'/N) N For bedrooms Now depth in. g.p.d. Fluid depth in absorption field before test in. Water added gal. Elapsed Time: min. Final fluid depth in. Absorption rote >= Any rejuv~natlon Ireatmeflt (past 12 mo.) (Y/N & type) N Soil rating (g.p.dJIt~ or ~AxIn~) ,.8 OPD/SF, System type lt. Width ~5 ft. Gravd below pipe 7 Eft. absoq:)tlon ama 574 fl~ Monitoring tube Y Depression over fluid N Results Municipality of Anchorage Department of Health and Human Services Division of Environmental Services On-Site Services Section 825 "L" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051 -061 -84 1, GENERAL INFORMATION Complete legal description HAA# 0 0 Expiration Date: Lot 6, Vern Haik Subdivision Location (site address or directions) Current Property owner(s) MM&M Contracting D~y phone Mailing address P.O. Box 670495 Chugiak, AK 99567 688-1236 Lending agency Mailing address Day phone Real Estate Agent Mailing Address Day phone = Unless otherwise requested, HAA will be held by DHHS for pickup. HAA picked up by: NUMBER OF BEDROOMS: Three TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class A Well [] Public Water System [] (3) TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank Community On-site Public Sewer The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water supply system. DHHS also issues HAAs upon request to home owners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation based on procedures outlined in the Health Authority Approval Guidelines for the Health Authority Approval application show that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on- site water supply and/or wastewater disposal system is in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, Name of Firm Address Ande~on Engineering Phone .~773 P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DHHS SIGNATURE /,.--"'" Approved for ~ bedrooms. Disapproved. Conditional approval for Date 9/14/00 bedrooms, with the following stipulations, Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Expiration Date: Original Certificate Date: Reissue Date: Legal Description: A. WELL DATA Well type A Date completed Total depth - Municipality of Anchorage E C E I V E D Department of Health and Human Services ~[p [ 4 20~)1] Division of Environmental Services On-Site Services Section 825 '%" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650MUNIOIP/~,ITY OF ANCHORAGE www. ci.anchorage.ak.us F-.NVIRONMI~NTAL SERVICES DtVISION (907) 343-4744 HEALTH AUTHORITY APPROVAL CHECKLIST Lot 6, vern Haik Subdivision Sanitary seal ft Cased to FROM WELL LOG Parcel LD.: 051=061-84 If A, B, or C provide PWSID # 211431 Well Log Wires properly protected __ ft Casing height (above ground) __ AT INSPECTION Date of test Static water level ft Well production g.p.m WATER SAMPLE RESULTS: Coliform colonies/100 mi Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel Date installed 8 / 2 / 00 Tank size Cleanouts ¥ Foundation cleanout ¥ Date of pumping New 'Construction C. ABSORPTION FIELD DATA Nitrate mg/t Other bacteria__ Oollected by: ft g.p.m in. colonies/1 O0 mi 1,000 gal Number of Compartments 2 Depression over tank N High water alarm __ Pumper N/A Date installed 8/3/00 Soilrating (g.p.d./ft20rft2/bdrm) .8 Length 41 ft Width 3-5 ft Gravel below pipe 7 Total depth 11 fl Effective absorption area 574 ft2 Monitoring tube Date of adequacy test New Const. Results (Pass/Fail) Fluid depth in absorption field before test __ in Water added Elapsed Time: min Final fluid depth in Any rejuvenation treatment (past 12 mo.) (Y/N & type) N System type Deep Trench ft Y Depression over field N For bedrooms gal. New depth Absorption rate >= __ If yes, give date __ in, g.p.d. 72 026 (Rev. 01/00)' D. LIFT STATION - N/A Date installed "Pump on" level at __ in Datum E. SEPARATION DISTANCES F. Size in gallons "Pump off" level at in Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Manhole/Access High water alarm level at ~n Meets alarm & circuit requirements No Well on Lot - PWS On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation > 5 ' Property line > 5 ' Water main N/A Water service line > 10 ' Drainage > 100 ' Wells on adjacent lots > 200 ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line > 10 ' Building foundation > 10 ' Water Service line > 10 ' Surface water > 100 ' Curtain drain None Noted Wells on adjacent lots > 200 ' COMMENTS Absorption field _ > 5 ' Surface water > 100 ' Water main N/A Driveway, parking/vehicle storage > 10 ' G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effebt on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 9/14/00 HAA Fee $ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 01/00)*