On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP181346 PID Number: 017-013-91
Dwelling: ®❑ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑ Upgrade
Name:
Kevin L. Lull
ABSORPTION FIELD
❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
12801 Patrick Rd, Anchorage, AK 99516
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
GPD/SF
Ft,
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
Kemp 1
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
IFt.
Well
>100'
N/A
N/A
NSA
>25'
TANK 91 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
11250 Gal.
Surface Water
>100'
N/A
N/A
NIA
Material
Number of compartments
Lot Line
>10'
N/A
N/A
N/A
Steel
2
NA
Foundation
>10'
N/A
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
1 Noted
Gal.
Remarks Tank is insulated with 2" of insulation.
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL House to tank D3034 Tank to
drainfield D3034
Installer
Denali Excavating
Drainfield Existinq CO/MT
Inspector J. Williams
BENCH MARK (Assumed elevation) 100 ft
Inspection151 10/10/18 10/15/18
Location and description
2nd
3`d 41h
Bottom of siding at SW corner of building
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date
�,,
, •!�
49 TH
W�
• ...........
• Benjart ' chiller
Approved Date
�Fc •., CE 12592
/x�F� • , 4/30/19 , • ��U r
��ROFESSI4N��
inspection Repori_a- i- i z.aoc
TALISMAN ROAD
10; -UTILITY EASEMENT
I EXISTING WELL.
I i
i
B i
y 2-BDRM HOME
i
'ANEW 1,250 GALLON
A SEPTIC TANK OUTSI
i 2C01
1 00'WELL RADIUS.
7
-/2CO2
SV
LOT 1
ABSORPTION PIT
30'ACCESS EASEiv'IENr
,WSC Bi: 214. PG 590)
A G. DRIVE _.
10 UTILITY EASE1,44ENT � ~
l d
Fes" �� i ENG I N E E R I N G
l
•
"ie C:2 •. I
49 TH
Senja in Schiller
CE q 4.
�p•pROFESS10��4�'�.
PLAN AS -BUILT
(NO SCALE)
PID # 017-013-91
A B
2CO1 19.2 36.8
SV160.6
78.7
S V2
61.7
83.5
2CO2
59.8
83.0
1 50 100
:_` .......Mv'
ME !FEET1
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEAN(
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
r'
t
1
I
t
1
1
.et
ti
f'
Ij
i
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEAN(
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
sang, TA Wdo a to"I
KEMP LOT 1
F9 FRE -3 DO VA RM W Mo
(NO SCALE)
2" INSULATION
M
co
49
...
..TH
.... ...
;-:.........
Benja m Schiller
Co 1 098
Nc,pA,,hof MUNICIPALITY OF ANCHORAGE
1,,cnr
On-Site Water&Wastewater Program �,� S
PO Box 196650 4700 Elmore Road _ '
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ,
http://www.muni.orgionsite j
\` / I)u•partnull t
On-Site Wastewater Disposal System Permit
Permit Number: OSP181346 Effective Date: 9/28/2018
Work Type: SepticTank Upgrade Expiration Date: 9/28/2019
Tax Code Number: 01701391000
Site Legal Address: KEMP LT 1 G:2840
Site Mailing Address: 12801 PATRICK RD, Anchorage
Owner: LULL KEVIN L Lot Size in Sq Ft: 59878
Design Engineer: FORGE ENGINEERING Total Bedrooms: 3
This permit is for the construction of:
❑ Disposal Field Q Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
..-, t_,1„:1
Received By: Date:
Issued By: PQM \,9..14.0Date: q a 3 18
Community Development Department 4 Phone: 907-343-7904
Development Services Division Fax: •. 34/3,79..ort
On-Site Water& Wastewater Program ittosk 71,
ON-SITE SEWER/WELL PERMIT APPLICATION Q SEP 2 7
U13
a �
Parcel I.D. 017-013-91
Property owner(s) Kevin L. Lull Day phone a6 8 L 9 5
Mailing address 12801 Patrick Road, Anchorage AK 99507
Site address Same
Legal description (Sub'd., Block & Lot) Kemp, Lot 1
Legal description (Township, Range & Section)
Lot Size 59,878 Sq. Ft. Number of Bedrooms Three (3)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(IA all that apply)
Absorption Field El Initial Single Family (SF) IX)
(w/wo ADU)
Septic Tank x; Upgrade I XI
Duplex (D) I I
Holding Tank ❑ Renewal I I
Multiple Dwellings I I
Privy I I (SF and/or D)
Private Well n
Water Storage I I
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: al5- Waiver Fees:
Date of Payment: q-as-q Date of Payment:
Receipt Number: OOM N Receipt Number:
Permit No. OSPIg kP Waiver No.
Permit App_2-: :_.,c
GE
ENGINEERING
PO BOX 240773
ANCHORAGE,AK 99524
522-7773 677-7766(FAX)
September 27,2018
Municipality of Anchorage
Development Services Dept-On-Site Water&Wastewater Program
4700 Elmore Rd
Anchorage,AK 99507
Subject: Kemp, Lot l — 12801 Patrick Road
Septic System Design and Permit Application
Dear On-Site Services Engineer:
The septic tank on the subject lot is leaking and must be replaced prior to the issuance of a COSA
for the property. The attached site plan identifies the location of the home and the existing well
and septic system. No conflicts exist between this proposed system and any other well or septic
system,whether on this lot or adjacent lots.
The new septic tank will be placed outside the 100' radius of the well on the lot and a minimum
of 5' from all deck or stairway foundation supports and all lot lines. The existing septic tank will
be decommissioned in accordance with Municipal Code.
The existing well on the lot is shown. The placement of the new septic tank will not encroach into
this radius or protective well radii on adjacent lots. Please refer to the attached plan sheet for the
septic design. If this design is followed,there will be no adverse impacts to adjacent properties.
Sincerely,14c-t-LAL
� QOFALsk
�*'•49 TH �\ *-:11
'y ��
rr
Michael E.Anderson, PE �
.. , • Yt....n
r F*Michael 3E81Anderson��/
�i``FD P•ROFESSION:4.4
\\\\\��„
KEMP SUBDIVISION LOT 1
S' 1
TALISMAN ROAD
--1(Y-UTILITY EASEMENT
/ \
/ N
/
I EXISTING WELL. \ i
\ //
'
PLACE FOUNDATION //
I CLEAN OUT. I /
® I /
1 2-BDRM HOME / I
/
1 I FCO 1 I /
0 /NEW 1,250 GALLON //
/SEPTIC TANK OUTSIDE
\ O/ 100'WELL RADIUS.
2CO3
(Yl - . ..'.1•,256�GALLON '. : / FSVV I
SEPTIC TANK. DEC.. SI,ON•,• / 2C0 1
LMS L ' PER M.O.A.CODE. /
- CONNECT TO EXISTING
\ _ _ — - SERVICE LINE. \
1 LOT 1 \\
\N
EXISTING ABSORPTION N
PIT. \
I
30'ACCESS EASEMENT /
(M ISC BK 214,PG 590) /
A.C.DRIVE /
10'UTILITY EASEMENT /
/
/
/
GE I /
/illoif
NGINEERING I
NOTE: I
_41011rlisi4, NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE
.�p� �Pr••�. �9..1. PROPOSED SEPTIC SYSTEM LEGEND
�..,..• •• �* CO-CLEANOUT
., ' � - s: �� 2C0-DOUBLE CLEANOUT
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
*-7417. 1m+49th _ \ s FCO-FOUNDATION CLEANOUT
• PROPERTY ARE SHOWN.NO CONFLICTS WITH WELLS OR SEPTIC
i "" SYSTEMS. FS-FLOW SPLITTER VALVE
?n MICHAEL E. ANDERSON 2te,k.d= MH-MANHOLE
•� .. No. CE-4381 •: � 0 50 100 MT-MONITORING TUBE
�1 �F'•••.,.• 9-27-18 ,.••cti NM = = I= FEET
+.�F� °ROFESS. Pia� 1"=50' SV SEPTIC VENT
•�1II.s ill,- TH-TEST HOLE
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
INSP~ECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
SEPTIC TANK:
DISTANCE FROM WELL
LIQUID CAPACITY
GALLONS.
NUMBER OF
MATERIAL ~'~'~' COMPARTMENTS
~-~'~'~ /~"~'"~"~'~"~'~' ~'~'~;~:~ LIQUID
INSIDE LENGTH ~""'~I~NSIDE WIDTH ~-~--' DEPTH
SEEPAGE SYSTEM: SEEPAGE PIT:
NUMBER OF PITS / OUTSIDE DIAMETER
LINING MATERIAL ~,,~9~/~~
~ OR WIDTH "~ 3
/,.
LENGTH .~2~ / ~'~'~
, , DEPTH
, BUILDING FOUNDATION
NEAREST LOT LINE./~1~'/~/'~' "~'~/
TILE DRAIN FIELD:
/
TOTAL EFFECTIVE ABSORPTIO~I A,~,EA (WALL AREA)
DISTANCE FROM WELL .~ ..... , FC~TION , NEAREST LOT LINE.
NUMB DISTANC TRENCH
DrEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE
SQ. FT.
TOTAL LENGTH
OF LINES
IN. TOTAL EFFECTIVE
IN. ABOVE TILE
WELL:
LOT LINE
TYPE ;,~.,,"~/~-,w..--.,~ . DEPTH ,~,~ ~ /
NEAREST ,,~...~ EPTIC
///-) '"-2/'""~ SEWER LINE ~'- ,TANK
DISTANCE FROM ~ WATER
.BU,LD,.G EOUNOAT O", SAMPLE . NEAREST
~/,/, / SEEPAGE /~'~ / ~..'"'~-O TH ER
DISTANCES:
DATE
DIAGRAM OF SYSTEM
APPROVED
HEALTH AUTHORITY
GREATEI~ AN~HOHA~I~ AHI~A ~l~U~Yfl Case No.~
- ~'~ HEALTH DEPARTMENT
327 Eagle St. Anchorage, Alaska 99501 279.2511 I 0 ?3(.it~ ~'~ '~?] ?0
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
NAME OF APPLICANT/~. ,~~ MAILING ABORESS~,''4 '~ ~7/C' PHONE NO.
RESIDENCE ADDRESS /"~'~'~/~' ~ ~ ~LOCATION OF INSTALLATION /~"~ ~ ~~
LEGAL DESCRIPTION ~g~ ~E~~5 T/2~ ~ f~
APPLICATION TO INSTALL: SEPTIC TANK ~ ., SEEPAGE PIT .~ , DRAIN FIELD , OTHER
TO SERVETHE FOLLOWING FACILITY ~~ ~~
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT .,
THIS IS TO SERVE AS ~
.AS OESCRIBEB BELOW,
., SEPTIC TANK SIZE
· PERMIT TO INSTALL A ,,4:~¢/,¢,'~ ~,v
SIZE OF UNIT TO BE SERVED
TYPE~ SEEPAGE AREA ~:~7~' TYPE
DIAGRAM OF SYSTEM
DISTANCES:
I certify that l am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the
above described system is m accordance with said code.
GREATER ANCHORAGT; AREA BOROUGH
CASE #
HEALTH D}ii,AkT?.1EN T '-
827 EAGLE f;TREET
ANCHORAGE · ALASKA
Depth ' Loe~tion Sketch
Soil Ch
Was Ground Water Encountered?__~.
If Yes, At
Reading Date
Gross ?ime
Nez Time
Depth To H?O
Net Drop
Field
~ ~~t
prooo~ed tn~tal~Seepage ~'t / O~,ain _ - -,~
- Depth To Bottom
Depth Of Inlet 2~_=-
COMMENT,>. .:_' .... ~ ' ' ---'--= -
November 17, 1970
l~r. Hent-/ Schroe~ter
Anchorage, Alaska 99502
~ ~/~, s~ i/a, ~ ~/~, '
Dear ~r. Schroedor:
S~nce the inspection of the subje~ se~er syst~, engineerin~
plans have been submit~eg and approved on Greet septic t~ks.
Enclosed please find y~r copy of the inspection repor~ livini
approval tot ~e se~er syste~.
Sincerely,
C.$. McKechnie
Environmental Health Aide
November $, 1970
Route A. ~ox aSOF
An~ho~e, Alaeks 99502
SUBJEC?~
The Greet eeptAo tank beAn~ used byyouon the eub~eet lot has not received
the approval of om~ Depatqment.~To~ th~s reasoa, the ~reer tank must be re-
moved and r~plaeedb¥ a Borough approved tank as eoen aa sprang break-up
makes di~g~ng p~aetieal.
Thank you very much i~or your
Sincerely,
John R. Lee, £.S.
Sanitar,ian
/omo
6R-RALS
MUNICIPALITY OF ANCHORAGE
•
ire
Development Services Department *". Phone: 907-343-7904
On-Site Water & Wastewater Section
-� Fax: 907-343-7997
Certificate of On-Site Systems Approval
Parcel I.D. 017-013-91 Expiration Date: E-( 0-47
1. GENERAL INFORMATION
Complete legal description Kemp Lot 1
Location (site address) 12801 Patrick Road
Current property owner(s) Kevin Lull Day phone
Mailing address 12801 Patrick Rd, Anchorage, AK 99516
Real estate agent Day phone
2. TYPE OF DWELLING:
Single Family (w/wo ADU)
n Duplex
Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Private Well Private Septic U
Water Storage ❑ Holding Tank ❑
Community Well ❑ Community ❑
Public Water System ❑ Public Sewer
Waiver request for Distance:
Received by: Date:
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ 5-67) Waiver Fee $
Date of Payment 671 1/19 Date of Payment
Receipt Number (1S 1ioq n Receipt Number
COSA# 6509/39 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation.
Name of Firm Forge Engineering Phone 907-522-7773
Address 1399 W. 34th Ave Suite 203, Anchorage AK 99503
Engineer's Printed Name Benjamin Schiller, P.E. Date 4/30/19
411 k
Aliv/V��0). ��— :7 fj
6. DSD SIGNATURE / •• "'• 2
X-- System #1 Approved for .3 bedrooms t •. Benja 7 chiller : j
CE System #2 Approved for bedrooms � �dl• 4 30192• ••••
l IF''Fo •pROFESS10N^ti.�
Disapproved
Conditional approval for bedrooms, with the following stipulations:
or A&Afi(
do(!�'%
ON-SITE �Q
WATER AND
WASTEWATER 0_,PROGRAM
SCJ//rOfJ <<c'
J)1;, T St}R`1\
r
Er
y: �- ( `� Original Certificate Date: (C
r I
The Municipality of Anchorage Development Services Division(DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checki st blue sheet
•
COSA Checklist
Legal Description: Kemp Lot 1 Parcel ID: 017-013-91
If more than 1 septic system on lot: COSA Checklist# of Structure served by this system
A. WELL DATA
El Well log is filed with Onsite (or attached) Well production at time of test 5.4 gpm
Date drilled *1970 Water storage tank volume 450 gallons
Total depth *330 ft Well disinfected for coliform test? ❑ Yes 0 No
Cased to *17 ft ❑� Coliform bacteria is Negative
❑■ Sanitary seal is functioning correctly Nitrate .541 mg/L ❑ Nitrate less than MRL (ND)
❑■ Wires are properly protected Arsenic ug/L Arsenic less than MRL (ND)
Casing height (above ground) 18 in. Collected by Forge Engineering
Date of flow test for COSA 8/31/18 Date of Sample 4/19/19
Static water level at beginning of test 19.7 ft.
Comments *Well info taken from original inspection report. Casing depth taken from new pump install log.
B. TANK DATA C. LIFT STATION
Age of tank(s) <1 years ❑ Required maintenance completed
Tank type/material Septic/Steel Age of lift station years
Measured operating fluid level in septic tank N/A Lift station material
❑� Standpipes/foundation cleanout per record drawing Comments: N/A
Date of pumping New Tank
D. ABSORPTION FIELD DATA Seepage Pit
Which system tested (date installed) 10/22/1970 Adequacy test date 8/31/18
❑� ALL standpipes present per record drawing Results E Pass For 3 bedrooms
Total measured depth from grade 12.5 ft (max) Fluid depth prior to test 69 in
Measured depth to pipe invert from grade N/A ft(min) Water added 577 gal
❑ N/A— pressurized field New depth 77 in
❑ Monitor tubes go to bottom of effective. If not, state 240
depth into effective N/A Elapsed time min
❑■ Code-required soil cover over field Final fluid depth 75 in
Absorption rate >450 gpd
❑ System presoaked
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) None
date of test)
Gallons introduced N/A gallons If yes, enter date
Comments/Deficiencies: Exact effective depth could not be accurately measured.Lateral drain pipe is not present in seepage systems.
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout> 100'
0 Yes if No ft El Yes if No ft
Neighboring Tank > 100' El Yes if No ft Private Sewer/Septic Line >25' El Yes if No ft
Absorption Field on Lot> 100' 0 Yes if No ft Holding Tank > 100' El Yes if No ft
Neighboring Absorption Fields> 100' Animal Containment> 50' 1 Yes if No ft
D Yes if No ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ElYes if No ft ❑✓ Yes if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations> 10' 0 Yes if No ft Surface Water> 100' El Yes if No ft
Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots:
Absorption Field > 5' CI Yes if No ft Private Wells > 100' 0 Yes if No ft
Water Main > 10' 0 Yes if No ft Community Wells> 200' ElYes if No ft
Water Service Line > 10' 0 Yes if No ft If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' 0 Yes if No ft If absorption field is under driveway comment below
Property Line> 10' 0 Yes if No ft Wells on Adjacent Lots:
Water Main > 10' El Yes if No ft Private Wells > 100' El Yes if No ft
Water Service Line> 10' DI Yes if No ft Community Wells> 200' 0 Yes if No ft
Surface Water> 100' 0 Yes if No ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION � OF Akoakki
�
I certify that I have determined through field inspections and review �)P.
of Municipal records that the above systems are in conformance with ,*g'• •M N.1.--..•:v *9
MOA COSA guidelines in effect on this date. % /\ •
•• * �0
r• Benja• chiller
�Fc
r •.. CE 12592 ....`4,E
fi 4.9: 4/30/19 ,.t, Ag
COSA Checklist yellow sheet �1�1 pRQFESS��14i
PLAT NO. 73-3
KEMP SUBDIVISION
LOT 1
59,878 S.F.
TALISMAN ROAD
0
N 89°26'45"E 179.81' •
10' UTIL. ESMT.
isits
it
t0
42.2' ' o• �a.
C9
30.7' fkyS>j^
ofck s6o•
6Ur4OrNC
rc
°��°w ci
rn
t m
o+
N
O O
Q m �
O q In
3 C ORr_,
30' 8
62 a
<
Q o
0 •
0 z SEPTIC SYSTEu
•
1 "=30'
30'ACCESS EASEMENT
(MISC BK 214, PG 590)
A.C. DRIVE
10' UTIL. ESMT.
•
N 89°24'47"E 199.88' •
AS -BU I L T I HEREBY CERTIFY THAT I HAVE SURVEYED THE
GASTALDI LAND PROPERTY DEPICTED ABOVE AND THAT NO ,n�)11•41
SURVEYING, LLC ENCROACHMENTS EXIST EXCEPT AS INDICATED. ** •OF.,41414..
IT IS THE RESPONSIBILITY OF THE OWNER TO •
JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, P''•• s1�•
2000 E. DOw ING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT *•; 49TH •••.: *•
ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBOMSION PLAT. � q.
PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA 0ro. ++jj
a . de ay a devote,
GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR ,; .��. 91 .. et
ESTABLISHING BOUNDARY OR FENCE LINES. ♦ ......... 6°;4411P
F.B. JOB NO. ANCHORAGE RECORDING DISTRICT, ALASKA •k �`s`�+::.•
NOTE: NO CORNERS SET THIS DATE
06-05 L1KEMP
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON'SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017-015-91
1. GENERAL INFORMATION
Expiration Date: / ~ -..~. ~ -//
Complete legal description KEMP LOT 1
Location (site address) 12801 PATRICK ROAD *ANCHORAGE, AK
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing. ad.al, tess
DUNCAN BOSLEY Day phone
12801 PATRICK ROAD *ANCHORAGE, AK
763-444-1320
Day phone
BILL BABYLON W/ PRUDENTIAL Day phone
3801 CENTERPOINT DRIVE *ANCHORAGE, AK 99503
351-4762
Unless otherwise '/~quested, COSA will be held by DSD for pickup.
NUMBER OF 'BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well · Individual On-site ·
Individual Water Storage [] Individual Holding tank []
Community Class Well [] Community On-site []
Public Water System [] Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
STATEMENT OF' iNSPECTiON BY ENGINEER
As cei'tified by my seal affb:ed hereto and as of the vafidation date shown be/ow, I verify that my
investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guideiines for this application,
sho~ that the on.-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
inform,,ation obtained from the Municipafity of Anchorage files and from .my investigafien and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY AG GARNESS, P.E.
Phone 357-6179
Date 9/~ ~ /II
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysi~ of the system in accordance with ADEC and MOA
DOD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
DSD SIGNATURE
~"" Approved for 2 bedrooms.
Disapproved.
Conditional approval for
· Pr, uuRAM -
bedrooms, with the following stipulations: ~
/,',,,'7~NT SF___\t~'.,'.?"
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
(Rev. 11/05)
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
U'EP~eF
Original Certificate Date: ~r_ ~. ~)..__ / /
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description:
WELL DATA
Well type PRIVATE
Date completed PRE
Total depth *94+ ft.
KEMP LOT 1 Parcel ID: 017-015-91
*PER GE(; FIELD MEASUREMENTS
**WELL INSPECTED BY AWPS (SEE A'FFACHED MEMO).
If A, B, or C provide PWSID# N/A Well Log (Y/N)
1970
Sanitary seal (Y/N) YES
*'17 TO
Cased to BEDROCK ft.
YES
Wires properly protected (Y/N) YES
Casing height (above ground) 12+
in.
FROM WELL LOG AT INSPECTION
Date of test NO WELL LOG 9/9/11
Static water level / ft. 27
Well production / g.p.m. 5.55
g.p.m.
Co
WATER SAMPLE RESULTS:
Coliform O colonies/100 mi.
Arsenic: ~ O,?"~ ug./L.
SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL
Tank size 1000 gal. Number of Compartments 2
Foundation cleanout (Y/N) *NO
Date of pumping 9/6/11
ABSORPTION FIELD DATA
Date installed 10/1970
Length 22 ft.
Total depth * 12.16 ft.
Date of adequacy test
Fluid depth in absorption field before test 83 in.
Elapsed Time: 244- min. Final fluid depth 87
Any rejuvenation treatment (past 12 mo.) (YIN & type)
Nitrate0, i')¢mg./L. Collected by: GEG, Ltd.
Date of sample: 9/9/1 1
*2"CLEANOUT LOCATED BY STEVE PANNONE. P.E.
INSIDE HOUSE ON WEST WALL, PER 10/11/06 COSA.
Depression over tank (Y/N) NO
Pumper
I'BELOW EXISTING GRADEI
Soil rating (g.p.d./ft2or~
225
Width 2.5 ft.
Eft. absorption area 810 ft2 Monitoring tube YES
9/9/11 Results (Pass/Fail) PASS
Water added 600 gal.
Date installed 10/1970
Cleanouts (Y/N) YES
High water alarm (Y/N) N/A
A+ HOME SERVICES
System type SEEPAGE PIT
Gravel below pipe 9 ft.
Depression over field NO
For 5 bedrooms
New depth 94.5 in.
__ in. AbsorPtion rate >= 450+ g.p.d.
NONE KNOWN If yes, give date -
D. LIFT STATION
Date installed
"Pump on" level at__
E=
in.
Size in gallons Manhole/Access ~ .__
"Pump off" leve~ High water alarm level at
Cycles tested. Meets alarm & circuit requirements?
SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
*50'+
Septic tank/lift station on lot
Absorption field on lot 100'+
Public sewer main N/A
Sewer/septic service line 25%
Animal containment areas 50' +
in.
On adjacent lots. 100'+
On adjacent lots 100'+
Public sewer manhole/cleanout
Holding tank N/A
Manure/animal excrete storage areas
N,/A
100'+
F=
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main N/A Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+
Water service line 10'+
Curtain drain NONE
COMMENTS
*ACCEPTABLE PER 1970
Building foundation. 10'+ Water main N/A
Surface water 100'+ Driveway, parking/vehicle storage
KNOWN Wells on adjacent lots 100'+
CODES. WELL WAS EXISTING IN 1970 PER INSPECTION REPORT.
10'+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date ~/ l~ /Ii
COSA Fee $
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
SGS Reft# 1114367001
Client Name Garness Engineering Group, Ltd Printed Date/Time 09/15/2011 16:15
Project Name/# Kemp Lot 1 Collected Date/Time 09/09/2011 13:49
Client Sample ID Kemp Lot I Received Date/Time 09/09/2011 15:10
Matrix Drinking Water Technical Director Stel~hen C. Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic 10.7 * 5.00 ug/L EP200.8 C (<10) 09/13/11 09/15/11 NRB
Waters Department
Total Nitrate/Nitrite-N 0.194 0.100 mg/L SM20 4500NO3-F B (<10) 09/12/11 AYC
Microbiology Laboratory
E. Coli Negative I 100mk SM20 9223B A 09/09/11 CR
Total Coliform Nezative I 100mL SM20 9223B A 09/09/11 CR
Municipality of Anchorage
Community Development Department
Development Services Division
On-Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Arsenic Advisory
Certificate of On-Site Systems Approval # 111349
A Certificate of On-Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block , Lot
1 of Kemp Subdivision. This inspection revealed an arsenic concentration of
10.7 micrograms per liter (ug/L) for the property's well water sample. The
Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems.
While private wells are not subject to this regulation, EPA standards are
based on existing health information and can therefore be used to gauge the
relative quality of water from private wells. Information on arsenic is
available from the On-Site Water and Wastewater Program website
(www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.
ARCTIC PUMP & WELL INC.
PO Box 770197
Eagle River, AK 99577
(907) 688-2510
(907) 258-2510
(907) 745-2510
apw~2,;~ci.net
Pump Installation Log
Well Drilling Permit Number: SW Date of Issue:
Parcel Identification Number:
Legal Description:Kemp
Lot: 1
Block:
Property Owner Name & Address:
Duncan Bosley
20171 Eidelweiss St Nw
C'~rl~r bANI ~qfll 1
Pump Installation Date: 9/15/2011
Pump Intake Depth Below Top of Well Casing:
Feet
Pump Manufacturer's Name: Dempster
Pump Model:
Pump Size: hp
Pitless Adapter Burial Depth:3 feet
Pitless Adapter Manufacturer's Name: Martinson
Pitless Adapter Installer: U/K
Well Disinfected Upon Completion? Yes
Method of Disinfection: Chlorine
Comments: Well casing set into bedrock at 17' no water intrusion above
40'
Pump Installer Name:
Arctic Pump & Well, Inc.
~4rctic Pump & Well, Inc.
Page 1 of/
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-79O4
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
1. GENERAL INFORMATION
Complete legal description Lot 1 Kemp S/D
Location (site address) 12801 Patrick Road, Anchoraqe, AK 99516
COSA# 0
Expiration Date: I ~ ~',~ Io'~-
Current Property owner(s) Mary Woodward
Mailing address P.O. Box 111906, Anchoraqe, AK 9951
Lending agency
Day phone
Day phone
Mailing address
Real Estate Agent
Day phone
Mailing Address
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage []
Community Class Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding Tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with vaIid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for eh'ors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(am) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Enqineerinq Se~ces, LLC Phone 272-8218
Address P.O. Box 102954, Anchoraqe, AK99510
Engineer's Printed Name .G. Scott Crowther, P,E. Date /4,
Engineers Comments: In conducting an ad~u~--'j tost, I sncmpt to provide a thorough, conscientious engineering analysis of thc system in
accorda~ee with MOA DSD Guidelines & Regulations. The reportcd results describe thc pert'orma~ce of thc system under thc conditions
encountered at thc time ortho test, and separation distances measured to readily idcntifiable features, Thc operational life of all wells and
septic systems depend on the local soil condition, ground water levels that may fluctuate during thc year, and thc water usage of thc family
be?g' sen, cd by thc system. These cond~bons' ' arc outside' thc control ortho cvaluator of this system. All. s/stems cventuall¥:~.~nd
satis factopj lest results do not guarantee futuro performance of thc system, nor do they guarantee that them arc no.~n
encroachments. PES can therefore not provide any warranty for future pe~l'ormanee nor glvc any estimate ofh~
continue to meet the operational reqmrements of the MOA DSD. The content ofth:s report is for thc sole be~,'~.~c owner
Any reliance upon or use oflhis report by any other person or part7 Is not euthori?~.d nor will it confer any~$,l,l ~'~h t whatso~$~'.7'
Approved[or bedrooms.
Disapproved. . 1~ ~,_\ o. scott
Cond,t,onal approval for bedrooms, with the following st'~~~.~
,_ ·
....
...'
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisor7
Nitrate Advisory
X Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onaite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: Lot t Kemp
ParcellD: O1'~- OI3-~1
A. WELL DATA
Well type _P. If A, B, or C provide PWSID #
Date completed u/~l~d Sanitary _=e-_! (Y/N) !
Total depth 330 ft. Cased to 4~ ft.
FROM WELL LOG
Well Log (Y/N) N
p opeW prot (Y/N)
Casing height (above ground) ~:~e in;,
AT INSPECTION
Static water level J ft. ! ~ ft.
Well production ~ g.p.m. ~,:) g.p.m
WATER SAMPLE RESULTS:
Coliform '-O '" colonies/100 mL ' Nitrate ,A,/T~ mg/L Other bacteria.-- O ~colonies/100 mL
Arsenic: /~.~1' mga Date of sample: ~/Z~o /= Collected by: ~ I?-13
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Gr~'Avnrov~J Steel Date installed t0/ZJ/'lg70
Tank size t000 gal. Number of Compartments 1_ Cleanouts (Y/N) Y
FoundaBor~ cleano,.ut~.~.Y~/N.)__.____~"_=...,Deprassicn over.,k (Y/N)N High~a~r alarm (y/N)N/A
Date of pumping ~/'~ Pumper
C. ABSORPTION FIELD DATA
Date installed t9123/t970 Soil rating (g.p.d./fl2 or ft3/bdrm) 225 System type
Length ~ ft. Width Z;) ft Gravel below pipe ~1 ff.
Totel depth tla3 ff. Eft. abeorpflon area I~11) ~ Monitoring tube Y DeDressidn over field N
Date of adequacy test ~)/2006 Results (Pass/Fail) PIqt For_3 bedrooms
Fluid depth in absoq3flon field before test 64 in. Water added ~'J0 gal. New depth69 in.
Elapsed Time: t260 min. Final fluid depth 65 in. Absorption rate >= ~ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N9 If yes, give date
D. UFT STATION
Date installed V~/'[ ~:~ Size in gallons ~ (Y/N)
"Pump on' level at ~.~1 at in. High water alarm level
at
Datum ./...,-'~ Cycles tested Meets alarm & circuit rsquiremerds?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Se~c ten~,t station on lot ~1'
Absorption field on lot 11~)
Public sewer main
Sewer Iseptic eewice line ~
Animal containment areas
On adjacent lots 11~)+
On adjacent lots
Public sewer manhole/cieanout
Holding lank
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation t~+ Pmpen'y line 1~
Water main ~ Water sewice line 25+
Wells on adjacent lots 11)0+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
absomtion fle~
Surface water
Property line
Water Service line
Curtain drain
F, COMMENTS
Building foundation
Sun'ace water
Wells on adjacent lots
Water main ~
Driveway, panVJngNehid® st~age t1~.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspec~ons and
review of Municipal tecon~ that the above systems are in
conformance with MOA C08A guidelines in effect on this date.
Engineer's Printecl Name G. Scott Cn:,~ef, p.~,
Date
cos Fee $4f I
(~. 1~)
Waiver Fee $
Date of Payment
Receipt Number
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
w~wv.muni.org/onsite
(907) 343-7904
Arsenic Advisory,
Certificate of On-Site Systems Approval # 060519
A Certificate of On-Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Lot I of Kemp
Subdivision. This inspection revealed an arsenic concentration of 16.9
micrograms per liter (ug/L) for the property's well water sample. The
Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of I0.0 ug/L for public drinking water systems.
While private wells are not subject to this regulation, EPA standards are
based on existing health information and can therefore be used to gauge the
relative quality of water from private wells. Information on arsenic is
available from the On-Site Water and Wastewater Program website
(www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.
SGS Ref.# 1065782001
Client Name Pannone Eng. Srv.
Project Name/# Lot l Kemp
Client Sample ID Lot I Kemp
Matrix Drinking Water
All Date~/Tlmes are Alaska Standard Time
Printed Date/Time 10/12/2006 12:36
Collected Dateffime 09/25/2006 16:00
Received Datefrime 09/26/2006 11:45
Technical Director Stephen C. £de
Sample Remarks:
Metals b~ ICP/MS
A~ic
16.9 * $.00 ug/L EP200.$ C (<10) 09/28'06 10/11/06 TIC
Wa~ers Department
Nitrate-N
ND 0.100 mg/L EPA 353.2 B (<10) 09/26/06 ALR
lq~ crobiolo~ Imborator~
TotalColiform 0 col/lOOmL SM209222B A (<1) 09/26/06 TLF
Environmental Consulting and Design
SEPTIC SYSTEM ADEQUACY TEST
LEGAL:
LOCATION:
OWNER:
RESIDENCE:
WELL:
SEPTIC SYSTEM:
Lot I Kemp S/D
12891 Patrick Road
Mar~ Woodward-Eddy
Single Family,Three Bedrooms
On Site Single Family
FROM MUlqlCIPAL RECORDS: 3 Bedroom System
TANK:
ABSORPTION SYSTEM:
ABSORPTION AREA:
SOIL RATING:
INSTALLATION DATE:
WAIVERS GRANTED:
Steel Tank, One Compartment.
Crib
gl0 Sq. Ft.
Unknown
10/23/I 970
None Required
DATE OF LAST PUMPING: issac's Pumping
DATE OF TEST: June 20t~ , 2006
TEST PROCEDURE: The septic tank was located and measured. After lank clean outs and a trench monitor
were located. The ~'ench monitor was 12.5 feet deep and contained 64 inches ofliquld.
Four handred seventy gallons of clean water was added to the system while the liquid levels in the tank and
the trench were monitored. The water level rose 5 inches in the trench monitor and remained constant in the tank.
After 21 hours the liquid level in the trench had dropped 4 inches, indicating that the system is capable of absorbing
over 600 gallons per day.
TEST RESULT: This system meets the code requirements of the ttealth and Social Services Department of
the Municipality of Anchorage.
NOTE: The operational life of all septic systems depends on the local soil conditions,
groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this septic system. We can therefore not give any
estimate of how long this system will function satisfactorily for current or furore occupants. All septic systems
ultimately fail. Some systems last 15-20 yearn, others fall after less than five years.
203 West 15t~ Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (907) 276-6013, SpurklandEng~gci.net
Environmental Consulting and Design
RESIDENTIAL WELL INSPECTION
LEGAL:
OWNER:
LOCATION:
Lot 1 Kemp S/D
Mary Woodward-Eddy
12801 Patrick Road
TYPE OF WELL:
WELL LOG AVAILABLE:
INSTALLATION REQUIREMENTS MET:
WAIVERS GIL~NTED:
WELL YIELD FROM WELL LOG:
WELL YIELD FROM TEST:
Private, Single Family
No
NO
None
Unknown
6.3 Gallons per Minute
DATE OF INSPECTION: 6/30/06
TEST PROCEDURE: The well was pumped at a constant rate. At pumping rate of 6.3 gallons per minute a total
of 470 gallons was pumped.
TEST FOR E.COLI AND TOTAL NITROGEN: Well was tested for E.Coli, total nitrogen, and Arsenic on June
26~, 2006.
RESULTS:
E.Coll. 0 Other Bacteria 0 Total Nitrate-N 1.44 mg/I Arsenic 14.1 ug/I.
Max. allowable Total Nitrate-N 10 mg/I. 10 Colonies of Bacteria Allowed
ND- None Detected
TEST RESULTS: Municipal code does not allow well pits. The well head must be upgraded to conform with
current code. Aarrow Pump & Well has been contacted to perform the required work. An arsenic content of 14.1
ug/l was determined. This is above the current EPA limit (5 ug/1). When a COSA approval is issued an arsenic
advisory will accompany it.
Tills WELL WII,L PRODUCE MORE TIIAN 3 GALLONS PER bllNIrrE FOR MORE TtIAN FOUR
tlOIJRS
The Municipal requirement for well flow is 150 gallons of water per bedroom per day. This well exceeds this
requirement. The assessment of the condition of the well applies only to the conditions as of the day tested. The flow
rate may change due to subsurface conditions that may not be observed from the surface, and changes in the land use
and other factors that may impact the aquifer feeding the well.
203 West 15tb Avenue Suite 203, Anchorage, AK 99501, Phone: {907) 279-3916
Fax: (907) 276-6013, SpurklandEng~gci.net
73-3
KEMP SUBDIVISION
LOT 1
59,878 S.F.
m
TALISMAN ROAD
~.¢.00' N 8g'26'45"E 179.81'
30'
1"=30'
42..2'
30.7'
~0" ACCESS EASEMENT
(MISC BK 214. PG 590)
A.C. DRIVE
10' U'nL. ESUT.
N 89'24'47"E 199.88'
A S- B U I L T , .~ cmn' MT, ..v~ su.v~_~
~CRO~HW~ ~1~ ~C~ ~ INDI~.
SURVEYING, LLC ff ISSUE R~NSIBI~ OF ~E OWN~ TO
4726 ~ 88~ A~uE C~ OR R~I~NS ~H ~ ~T
~CHO~G~ ~ 99502 ~P~ ON ~E RECORD~ SUBDMSION P~T,
PHONE 2~-5454 UNDER NO CI~UM~C~ SHOU~ ~ DATA
CEID DA~ H~EON BE ~ ~R ~N~;~U~N OR ~R
28~ 5/15/2006 ~USHING ~UN~ OR ~E UN~,
~CHO~GE RECORDING DI~I~, ~
RD. JOB NO,
06-05 L1K~P N~ NO ~RN~S S~ ~IS ~