Loading...
HomeMy WebLinkAboutMICHLIG LT 1 DOC CO dba BILL S. COLE 400'. ULLIVAN WATER WELLS P.O. Box 670269, Chugiak, AK 99567 688-2759 www.suilivanwaterwells.com Pump Installation Log Well Drilling Permit Number: SW Date of Issue S U-) 9 S7 00 Z� Parcel Identification Number: 051— 1( 1_ 3 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. DHI CONSULTING Civil · Surveying ENGINEERS · Planning March 16, 1999 WO: 98399 Mr. Jim Cross Department of Health & Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Re: Lot 1, Michlig / Permit No. SW990021 RECEIVED MAR 19 1999 Mut~icipality of Anchorage Oept, Heaith& Human Services Dear Mr. Cross, I am in receipt of your February 26t~ letter concerning the expiration for the above referenced permit. In ,July, I wrote a letter to your office informing you that the above system had been installed and that I was waiting for the Owners to construct their home so that I could obtain the required swing ties. I contacted the Nielsen's (property Owners) and they now have their house far enough along that I can obtain the swing ties. Unless you have an objection, I'd like to wait until the snow melts so that I can locate all the clean outs. I should be able to turn the record drawings in by the end of May. Since the system is completed with the exception of the of record drawings, I assume that a new permit will not be required. If this is not correct, please notify me as soon as possible. 3990116M.Itr cc: Caela Nielsen Dimond Center Tower, 5th Floor * 800 E. Dimond Blvd., Suite 3-545 * Anchorage, Alaska 99515 (907) 344-1385 ° Fax 344-1383 Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci.anchorage.ak.us February 26, 1999 Lance Clayton & Caela Jean Nielsen PO Box 671056 Chugiak, Alaska 99567 1056 Subject: Lot 1 Michlig Permit # SW990021 PIE) # 051-161-31 The subject permit, issued February 25 1998 by this office for a single family well and/or on-site wastewater system, has expired as of February 25, 1999. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to tiffs office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater perm/t; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Program Manager On-site Services enc: Copy of Permit PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW980021 DESIGN ENGINEER:DHI ENGINEERING OWNER NAME:NIELSEN LANCE CLAYTON & OWNER ADDRESS:1665 SITKA STREET #101 ANCHORAGE, AK 99501 DATE ISSUED: 2/25/98 EXPIRATION DATE: 2/25/99 PARCEL ID:05116131 LEGAL DESCRIPTION: MICHLIG LT 1 LOT SIZE: 44929 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: AT THE TIME OF CONSTRUCTION AN ADDITIONAL SOILS TEST SHALL BE PERFORMED TO COVER THE AREA AT THE SOUTH END OF THE BED. A SOILS LOG OF THE BED WALI~..AND PERCOLATION TEST RESULTS SHALL BE INCLUDED W~TH THE ~S~UILT PACKET. RECEIVED B ~ DATE: Page: 1 Document Name: ENTERPRISE SERVER PARCEL: 051-161-31-000-00 CARD: 01 OF 01 RESIDENTIAL SINGLE FAMILY STATUS: RENUMBERED TO/FROM: 000-000-00-000-00 NIELSEN LANCE CLAYTON & MICHLIG CAELA JEAN LT 1 PO BOX 671056 CHUGIAK AK 99567 1056 SITE 19942 LORI ST LOT SIZE: 44,929 ---DATE CHANGED ....... DEED CHANGED--- ZONE : R6 OWNER : 11/13/97 BOOK : 3149 PAGE: TAX DIST: 022 ADDRESS: 06/11/98 DATE : 11/03/97 GRID : HRA # : 000000 PLAT : 840341 NOTES : REF 051-161-12 .................................. ASSESSMENT HISTORY ...................... ---LAND .... BUILDING .... TOTAL--- FINAL VALUE 1997: 8,900 0 8,900 FINAL VALUE 1998: 25,800 0 25,800 --EXEMPTION FINAL VALUE 1999: 30,700 49,200 79,900 ..... TYPE-- EXEMPT VALUE 1999: 0 0 0 STATE EXEMPT 1999: 0 FINAL VALUE 1999: 79,900 -COMM COUNC BIRCHWOOD Date: 2/26/99 Time: 08:15:42 AM DHI CONSULTING Civil · Surveying ENGINEERS · Planning Mr. Dan Roth Department of Health and Human Services P.O. Box 196650 Anchorage, AK 99519-6650 July 17, 1998 W.O.: 98340 RECEIVED JUL 20 1998 Municipality of Anchorage Dept, Health & Human Services RE: On-Site Well and Wastewater Disposal System/Permit SW980021 Michlig Subdivision, Lot 1 Dear Dan: The septic system for the above referenced lot has been installed. This letter is to inform you that I cannot submit the record drawings within the time allowed by the regulations. The house will not be constructed for some time (possibly this fall), so I am not able to obtain the required swing ties from a structure. If you would like a preliminary set of record drawings or if you will accept swing ties from the property corners, please call and I will forward a set of record drawings. The owners will contact you if they see a delay in providing the record drawings past first of the year. Please give me a call if you have any questions. Very truly yours, ~Rl~sulting Engineers cc: Lance and Caela Nielsen, Properly Owners 340dr22u.ltr Dimond Center Tower, 5th Floor ° 800 E. Dimond Blvd., Suite 3-545 · Anchorage, Alaska 99515 (907) 344-1385 · Fax 344-1383 DHI CONSULTING Civil · Surveying ENGINEERS · Planning W.O. 98339 SITE NARRATIVE Project: Lot 1, Michlig Subdivision Lot 1, Michlig Subdivision is located west of Lorian Street in Birchwood. There has been development on the lot to the northeast of this lot. See sheet 4. Domestic Water: There are no wells or septic systems within 200' of the proposed improvements as shown on sheet 4 of the enclosed design. The subject lot is proposing to drill a private well. The well and its protective radius will have no adverse effect on the surrounding lots. Septic System: The subject lot has a series of benches and slope which range between 4% and 15%. The proposed bed system can be installed without requiring any waivers to seasonal high water table or bedrock. There will be no adverse effect on the surrounding lots. Drainage: The drainage, in general, is from the east to west. When the property is developed, the general drainage should remain the same. There is enough slope to the property so that the lot can be landscaped to prevent ponding around the septic system. There is a small drainage swale located on the lot to the north. The swale is shallow and appears to carry water intermittently throughout the year. The subject septic system should remain 100' from the swale. There are no other streams or other drainage channels on or within 100' of the lot. All disturbed areas will receive topsoil and seeding to prevent erosion. Summary: The proposed well and septic system can be installed in conformance with existing Municipality of Anchorage regulations and will not adversely impact adjacent lots relative to their ability to construct a system in accordance with Department of Health and Human Services regulations. 33gnar. rep Dimond Center Tower, 5th Floor · 800 E. Dimond Blvd., Suite 3-545 · Anchorage, Alaska 99515 (907) 344-1385 * Fax 344-1383 Perm[f,, No. Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196690' Anchorage, AK 99519-6680 ° Tel: 343-4744 Page 1 of 5 W.O. 98S29 Date 1/27/98 On-Site Wastewater Disposal System/Well Inspection Report Legal Description: LOT 1 MICHLIG SUBDIVISION PID No. REPLACEMENT SYSTEM DESIGN CALCULATIONS 1. NO. BEDROOMS - ,5 2. USE BED SYSTEM 5, ABSORPTION AREA = (# BEDROOMS)(150 GPD/BR) BED APPLICATION RATE = (3)(150) = 562.5 SE 4. BED AREA = (LENGTH)(WIDTH) IF WIDTH = 15' THEN LENGTH OF BED 37.5' : USE 40' *1 PERCOLATION RATE MIN/INCH 0-1 MOUND & BED APPLICATION RATE 1-5 GPD/SF NOT SUITABLE 6-15 16-50 · 51-60 GREATER THAN 60 FILTER LAYER o.8 ] 0.5 0.4 NOT SUITABLE .7 PIT & TRENCH APPLICATION RATE GPD/SF NOT SUITABLE 1.2 0,8 0.6 0.45 NOT SUITABLE !.0 329CSD1D ~. ~ '% CE 5807 DATE Permi, No. Legal Description: Poge_2 of 5 LOT 1 MICHLIG SUBDIVISION W.O. 98329 NOTES: Date 2/18/97 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 15.65. WASTEWATER DISPOSAL REGULATIONS OF THE MUNICIPAL CODE, AND THE MOA STANDARD SPECIFICATIONS (MASS) 1994, AS CURRENTLY AMENDED. INSTALL NEW 1,000 GAL. 2 COMPARTMENT STEEL SEPTIC TANK WITH LIFT STATION AS MANUFACTURED BY ANCHORAGE TANK, MODEL #AT1250L. INSTALL PUMP CONTROL PANEL WITH HIGH WATER ALARM LIGHT & HORN IN HOUSE. FINAL LOCATION TO BE COORDINATED WITH OWNER. ALL WIRING TO BE IN ACCORDANCE WITH ALL LOCAL, STATE & FEDERAL CODES & REGULATION. IF TANK IS PLACED WITHIN 2' OF SEASONAL HIGH WATER TABLE, INSTALL SPECIAL BUOYANCY DESIGN WILL BE REQUIRED TO PREVENT FLOATATION. CONTACT ENGINEER. 5. ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGINEER PRIOR TO ITS INCORPORATION INTO THE SYSTEM. 4. MIN. COVER OVER DISCHARGE PIPE TO BE 5'-BED PIPE IN SAND. SLOPE PiPE TO DRAIN BACK TO LIFTSTATION. INSTALL 2" OF INSULATION OVER PiPE UNDER DRIVEWAY. 5. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY LINES, EXISTING WELLS, WATERWAYS, SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. CONTRACTOR TO STAKE PROPOSED SYSTEM PRIOR TO CONSTRUCTION. MAINTAIN 100' CLEARANCE FROM ALL WATER BODIES, WELLS & DRAINAGE SWALE & 50' FROM ALL GRADE BREAKS GREATER THAN 25%. NOTIFY THE ENGINEER OF ANY OBSERVED CONFLICTS PRIOR TO CONSTRUCTION. 6. CONTRACTOR TO CALL THE ENGINEER AND DHHS 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. A MINIMUM OF THREE VISITS ARE REQUIRED. THE FIRST VISIT SHALL BE OF THE SUBGRADE PRIOR TO PLACING THE SEWER ROCK. THE SECOND VISIT SHALL BE AFTER THE PLACEMENT OF SEWER ROCK, DISTRIBUTION PIPING, STANDPIPES, AND OTHER COMPONENTS AS SPECIFIED. THE THIRD VISIT SHALL BE AFTER THE WORK IS COMPLETED. 7. CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED-LINED, AS-BUILT DRAWINGS SHOWING ALL DATA AS SPECIFIED IN SEC. 15.65.F.2, ,3, 4, 5, 6 OF MUNICIPAL WASTEWATER DISPOSAL CODE WITHIN FIVE DAYS OF THE FINAL INSPECTION. INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT. THESE AS-BUILTS SHALL BE USED BY THE ENGINEER TO PREPARE AND SUBMIT RECORD DRAWINGS TO DHHB. 8. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN. 9. EXCAVATE THE ABSORPTION FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE, AND END OF BED BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 10. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO _+ 1" PRIOR TO INSTALLING THE PERFORATED PIPE. 11. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D5054 OR ENGINEER-APPROVED EQUAL. ALL JOINTS SHALL GLUED WITH AN APPROVED GLUE. CLEANOUTS SHALL BE INSTALLED AS SHOWN ON PLANS TO ACCESS ALL PIPE RUNS. 4" MONITORING TUBES SHALL BE INSTALLED WHERE SHOWN ON PLANS. 12. COVER THE DISTRIBUTION PIPES WITH MIN 2" SEWER ROCK, BEFORE PLACING INSULATION, GEOTXTILE, FILL, AND TOPSOIL. .% MINIMUM SOIL COVER SHALL BE 4- FEET OVER THE PERFORATED PIPE AND 4- FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER, BUT THERE MUST BE A MINIMUM OF 2' OF COVER OVER THE INSULATION. ALL INSULATION BOARD SHALL BE 2" THICK BY 2' WIDE DOW HI-55 INSULBOARD OR ENGINEER-APPROVED EQUAL. 14. AN APPROVED DRAIN FIELD FILTER GEOTEXTILE SHALL BE INSTALLED BETWEEN THE SEWER ROCK AND THE BACKFILL. 15. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 16. SLOPE ALL FILL MATERIAL AND TOPSOIL TO DRAIN AT 2% MIN. SLOPE, AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. THE TOP 6" OF COVER SHALL BE TOPSOIL. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MUNICIPAL SPECS. 529CSD2D Permff, No. On-Site Wastewafer Disposal System/Well Legal Description: LOT 1 btlCHLIG SUBDIVISION Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 .Anchorage, AK 99519-6650 .Tel: $43-4744 Inspection Page_.,~ of 5 Date 1/28/98 Report / /~ ,~OPOS~D ~ / ~ASEMEN~ ........ / / / / T 65 / / / W.O. 98539 JF.B., NO. ISCALE: 1"= 100' ,C. FILE 329CSD4D ' Permif. No, Municipality of Anchorage Poge. 4 of 5 Department of Health and Human Services r~_~ 1/20798 ENVIRONMENTAL SERVICES DIVISION - P.O. Box 196650 * Anchorage, AK 99519-6650. Tel: 343-4744 kegs[ Description: LOT i MiCH~G SUBDiViSiON J ~ / / / ./ '~' '""' ~-APPROXIMATE LOCATION OF / 'N LOT 35 SHOULDER-~ j , /./ ss~'~9,oo"E _ ~_~ /~ ,¢7 ~ · ':~'~ /W~~- ~ .:'::)/ LOT 1 , .. L,,o,oj :'z: :'..~ ~ / SEPTIC TANK ..... x m. / w/ LIFT STATION~I / AREA FOR LOT 2 FUTURE REPLAC~ / SYSTEM ~ I w.o. 98329 I c.o.---_.<..-----~ ~ ~ LEGEND / ~/~,., · CLEANOUT OFFSET I I LI~ i ..,;--,,_ m DISCHARGE ~ I J PIPE (5 TYP.) ee A. MAINTAIN 100' PLUS DISTANCE BETWEEN DRAINAGE SWALE & ANY PART OF LEACH FIELD/SEPTIC TANK. I I J F.B. NO. I SCALE: 1" = 50' lC. FlEE $2BCSD~ I I I Pe~mif. No. Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * A~chorage, AK 99519-6650 *TeI: 343-4744 Well & On-Site Wastewater Disposal System Legal Descripfion: LOT 1 ~.. ~-.- bfX\Q! [ Poge 5 of 5 W.O. 97559 Dale 1/27/98 PID No. ORIGINAL GROUN ORGANIC SILTS NFS SAND FINISH GRADE~ .- / 4" PERFORATED PIPE r'~ SEPTIC ROCK PER M.O.A. SPECIFICATIONS SEE NOTE 10 .~-4" INSULATION /SEE NOTE 1~3 GEOTEXTILE FABRIC SEE NOT£ 14 ~4" MONITORING TUBE PERFORATE LAST 1'-0" 7WATER TABLE ~--TO ANY SEASONAL HIGH WATER LEVEL TO ANY BEDROCK OR IMPERMEABLE LAYER TYPICAL TRENCH 8EC'I'ION 529CSDSD W,O.# 97329 ,"~ ,~ ~ DEPAR~ENT OF HEALTH · HUMAN SERVICES SOILS L~-PERCO~TION ~ST PERFORMED FOR: CAELA N ELSEN DATE PERFORMED: 10-15-97 LEGAL DESCRIP~ON: LOT 1 '~ MICHLJG SUB. TO~SHIP,RANCE,SEC~ON: ~/~ ~ ORGANIC SILTS 1 ~'~::~ ~' SLOPE SITE PLAN ':::"'~ ~: ;:': "'"':'~ tj:;-J";:.?/". :':'-~'~':;':::':(:::::~ ~ WATER TABLE ~ ::~ ;.~.~'..':-,-::- . 9 -I I WAS GROUND WATER S 1 0 ENCOUN~RED ? YES L 0 11 ~F YES, AT ~AT p DEPTH ? 7,0' DEPTH OF WATER ~, ~ 12 - ~ AFaR MONITORING ? * / '- DATE: * ' I i I 15 j I 16 I ~7 !- i I lg PERCOLATION RATE: <1.0 (MINU~S/INCH,) PERCHOLE DIAMETER: 20 TEST RUN BET~EN: 2.5 FT. AND 3.0 FT. COMMENTS: WATER RUN OUT AS FAS~ IT WAS PUT IN. PERC RATE IS LESS ~AN 1 MtN./INCH. (. ~ ,In' PERFORMED BY: DEE HIGH .... ~L STA~ ANO ~UNCPA~ ~U~OEUNES~ e'eN ~rF~CT ~m~S gA~. DA~: ¢-~'f~ ~2gC~D J REAOING OA~ G~OSS l~U£ NET ~ME WATER NET DR~ 3 10-15-97 1GSEC. 6" 6" <1.0 I J