Loading...
HomeMy WebLinkAboutWARD LT 5Ward Lot 5 #011-122-84 Inspection Repolt-1-1-12.doc Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. - P.O. Box 196650 Anchorage, AK 99519-6650 • hftp://www.muni.org/onsite - (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP131106 PID Number: 011-122-84 ❑� New ❑ Upgrade Name: Merit Homes LLC ABSORPTION FIELD R] Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 1920 W. Dimond, Suite F Anchorage, AK 99515 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 334-9233 5 1.0GPD/SF 10 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4 FL Gravel depth beneath pipe 6-OFt. Subdivision Block Lot Ward 5 Fill added above original grade 4-5 Ft Gravel length 64 Ft Township Range Section Gravel width 3Ft Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 768 Fe 1 Ft Well N/A N/A N/A N/A N/A TANK a Septic S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity I 1,50OGal. Surface Water >100' >100' N/A N/A Material Steel Number of compartments Two Lot Line >5' >10' N/A N/A NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Municipality of Anchorage Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Red Dog Excavating Drainfield F810 CO/MT D3034 Inspector MEA BENCH MARK (Assumed elevation) 100.Oft Inspection,e 1 6/17/13 6/17/13 Location and description dates: 3r° 6/18/13 2w 4'" Lower Level Concrete Floor. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp .OFA4k 4L gSti�go Conditional Approval: Date ,Q��'-.... O :�04 4'TH . *#i 00 ...r«r«�..• �n rb 101ABI. F ANDERSON 0 W s✓ S CE - 4381so Y Approve Date 3 ` l �it;tie 000* E `oma®• ` Inspection Repolt-1-1-12.doc Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Permit Number: OSP131106 PID No. 011-122-84 PENNY ROSE CIRCLE LEGEND FCO — Foundation Clean Out C4 — Clean Out M1 — Monitor Tube TH — Test Hole SV — Septic Vent PLAT NO. 2006-13 WARD SUBDIVISION LOT 5 41,238 S.F. f=rM01i119MI SCALE 1' = 40' Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP131106 PID No. 011-122-84 i� Finished G.d. ar.a 92.8 nshng a e Geotextile Fabric 88.9 grainfield Rock .77-- 82.9—/82.9 74.8 64' (Trench Length) No Groundwater 5-31-13 PROFILE AS -BUILT No Scale MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 5, WARD SUBDIVISION PERFORMED FOR: MERIT HOMES LLC DATE: 6/17/2013 PROJECT No.: PARCELID#: TECHNICIAN: A. HARALA DEPTH TEST HOLE 11 (feet) NET TIME (MINUTES) 1 NET DROP (INCHES) OB/OG SLOP[ 2 1 9:15/9:25 10 .50"/9.50" 9.00" 2 SILTY SAND 10 3 9.00" WITH GRAVEL 9:37/9:47 10 .63"/9.50" 8.87" SM/SP 4 4 10 .75"/9.75" 9.00" 5 9:59/10:09 10 .75"/9.63" 8.87" 6 6 10:10/10:20 BOH @ 6' .63"/9.50" 7 8 9 ° 49th �h V✓l.r-+-�.-o--es � lir-dL R'; M[C"AEL E- ANDERSON ? 4 SITE PLAN SEE SITE PLAN i 10 WAS GROUND WATER ENCAUNCERED? No IF YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: - 2% 1 1 DATE OF MONITORING: P 1 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEWPTH TO ATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 6/17 1 9:15/9:25 10 .50"/9.50" 9.00" 2 9:26/9:36 10 .75"/9.75" 9.00" 3 9:37/9:47 10 .63"/9.50" 8.87" 4 9:48/9:58 10 .75"/9.75" 9.00" 5 9:59/10:09 10 .75"/9.63" 8.87" 6 10:10/10:20 10 .63"/9.50" 8.87" PERCOLATION RATE: 1_13 (MINANCH) PERC. HOLE DIA. 6f� (INCHES) TEST RUN BETWEEN: 6 FT. and 7 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERCOLATION TEST ONLY. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 3/5/2014 MEMORANDUM DATE: March 5, 2014 TO: Reviewer FROM: Mike Anderson, P.E. SUBJECT: Lot 5, Ward Subdivision Septic System Permit No. OSP131106 The excavator graded the lot nearly flat prior to the construction of the absorption trenches. He then placed the alignment of the trenches slightly different than on the permitted plan. Jeff was onsite during the initital inspection and verbally approved the placement and alignment of the trenches. The placement of the trenches is in compliance with the original permit. On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131106 Tax Code Number: 01112284000 Work Type: Septic Permit Effective Dates: June 03, 2013 to June 03, 2014 Design Engineer: ANDERSON ENGINEERING Subdivision: WARD Site Legal Address: WARD LT 5 G:2222 Owner/Address: PETERSEN KENNETH C & GLADYS M 1301 ROSEHILL BLVD SCHENECTADY NY 123092525 Site Mailing Address: Lot Size in Sq Ft: 41238 Total Bedrooms: 5 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division QD Fax: 907-343-7997 On -Site Water & Wastewater Program Parcel I.D. ON-SITE SEWER/WELL PERMIT APPLICATION 011-122-84 Property owner(s) Kenneth & Gladys Petersen Day phone Mailing address 1301 Rosehill Boulevard Schenectady, NY 12309 Site address Penny Rose Circle Anchorage, AK Legal description (Sub'd., Block & Lot) Ward, Lot 5 Legal description (Township, Range & Section) Lot Size 41,238 Sq. Ft. Number of Bedrooms Five (5) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ER Single Family (SF) [Z (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. owner or authorized Permit/Rush Fees: 536, W Waiver Fees: Date of Payment: �.'�9A Date of Payment: Receipt Number: )tacit) Receipt Number: Permit No. OQJI0I3 Waiver No. Permit App_: S:L,:c.: May 24, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 5, Ward Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 5, Ward Subdivision intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The subdivision is served by the AWWU water system. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site. No existing wells are closer than 100' from the proposed septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the tract in the area of the absorption trench and alternate site indicated clean sand (SM/SP/SW) material with some silt. The percolation rate of the soil was determined to be less than 1 to 1.5 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.0 gallons per day per square foot was used in the design of the absorption system to allow for the sandy material and the fast percolation rate. We are proposing to place a new 1,500 -gallon septic tank and a 63' long by 3' wide by 6' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 4' below the surface and the total depth will be 10'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the northeast at a grade approximating 7%. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal Lot 5, Ward Subdivision May 24, 2012 Page Two requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments MICHAEL E. ANDERSON No. CE -4381 Hanks Subdivision Lot 2 40,262 sq.ft. VACANT Let 3 I� r ------------ ---c— I I �J Im ------------- 1m c— rn Lot 1 1 o O m 40,168 w o u I� --4 m sq.ft. rn N I� o m NNY I� _ - -_ - — ROSE I I� O Hanks Subdivision Lot 2 40,262 sq.ft. VACANT Let 3 I� S00'13'36"E I �J Im 49.97' 1m 114.01' 134.00' 1 i— --------249.83'---- --4 - o NNY _ - -_ - — ROSE O S89'51'10"W 329.76' o CIRCLE --249— _ 113_95' —"'— 134.00----------- - C2 S0013'36"E - - I 50.03' 15' Gas Esmt \ ` t 10' T&E Esmt Drainages \ \ o0 o Esmt o c� \ ��\\ I w Lot 9 o C Lot 8 u o 'w Lot 7 \\ ri 40,155 N 40,250 0 42,134 a sq.ft. n' sq.ft. N sq.ft. \\ m L4 I 10' T&E Esmt—,, I I i L 10' Utility Esmt ------ 133.99'---- - -'134.00''--- ------------- 223.06'----- 50' Ratcliff'ie Subdivision 1 3 2 1 AREA PLAN SCALE 1" = 100' wt s zC-z Lot 4 1 Lot 6I\ 45,681 0 1.1 sq.ft. a I� NIN Io 0 49th �'; MICHAEL E. ANDERSON �ypi 'fii •.. No. CE -4381 r�.c. 1 PLAT NO. 2006-13 WARD SUBDIVISION LOT 5 41,238 S.F. 0, I? p101 R� x O I I I I I I I I I I I I I I I I I I� IV) Iw o I� o I~ � I� o I. N O o z I I I I I I I I I I I I I I I I I I ;LLEVATION72 NGS DBASEDATUM (0 235 SITE PLAN SCALE 1' = 40' 63 ,Lon x, 3' Wide tTre 15' GAS ESMT. Absorption ch A`9 c0 240' Xr---, \ 239. 9' - Water site 1 Service Alternate ~� I EL. G. SLAB = 240.0 L — 240.5' Tank PENNY ROSE A.C.1 DRIVE 1 Fc0 1500 e tic CIRCLE I Five Bedroom sv sv 2co 240, xLII Home hN r 1 239.2' / co ®to Z-- x zaa.s' LEGEND FCO — Foundation Clean Out CO — Clean Out S 62�g MT — Monitor Tube �9F TH — Test Hole SV — Septic Vent 26� I I I I I I I I I I I I I I I I I I� IV) Iw o I� o I~ � I� o I. N O o z I I I I I I I I I I I I I I I I I I ;LLEVATION72 NGS DBASEDATUM (0 235 SITE PLAN SCALE 1' = 40' LOT 5, WARD SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home Deep Trench System Perc. Rate: < 1 Min./Inch 1,500 Gallon Septic Tank Application Rate: 1.0 GPD/SF 6' Drainfield Rock 5 Bedrooms X 150 GPD/1.0 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/12 SF/LF = 62.5 LF Trench Length THEREFORE: Construct a 63' Long x 3' Wide x 6' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 10' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area. Natural Backfill 3'6" Geotextile Z'14 Fabric 6„ 4" Perforated PVC (Holes Down) 6'0" 1 I �— Drainfield Rock 3' TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. Municipality of Anchorage Development Services Department Building Safety Division • On -Site Water and Wastewater Program 4700 South Bragaw St. P,O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Performed For: Legal Description: Depth h� l (Feet 491H 20 -WCHAEL P ANDERSON 6 •. CE -4381 .•�t'a gb_949 A^ 6. .*0 ����a 00111S Log - Percalatian Test lqmrr 4uAl. Lf -'s Date Performed: - .�-- s4,jmkQ Township, Range, Section: _ 1- Date Gross Time o(, 2- Net Drop P ✓ 9�/ brY) t�tn� 3- ,. i 1649�3 f2Cr 4_ (p � 7- 8- 10- 11 14- 15- 16- 17- 491H 4 -15- 16- 17- COMMENTS 5� L'.AS GROUNDWATER A— riNCOUNTERED? e Fa1,� IYXGI AT WHAT DEPTH? 0 Depth to Water After �% P 119 k t �ry Monitoring? ' • c�� E Date: S' 31 1 3 Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop ,. i 1649�3 f2Cr fL.f®t (p � 17 �o�f -�S STs 12f�f S � PERCOLATION RATE G f -o Iminuws(inah) PERU HULL UTAMt I to ) TEST RUN BETWEEN FT AND 5r FT PERFORMED BY: Al�-— I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCdRDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Municipality of Anchorage 6 Development Services Department 00 i Building Safety Division 00` 0 y-, On -Site Water and Wastewater Program 4700 South Bragaw St. o 0 P.O. Box 196650 Anchorage, AK 99519-6650 iP www ci anchorage. ak. us p+j Gn E 07) 343-7904 SO'!T14,? Soils Log 90Percolation Test ��o lZ 3lA• Performed For: AVZ4 7- AW Date Performed: Legal Description: T- Township, Range, Section: _ Depth nCs (Feet) 1- 2 of 4- 5 C tej 6- �t'a 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- COMMENTS 5t WAS GROUND WATER 6 ENCOUNTERED? /V 0 Depth to Water s IF YES, AT WHAT DEPTH? L e Depth to Water After iP Monitoring? p+j Gn E Date: SO'!T14,? 491, �,. MICHAEL E. ANDERSON GE - 4361 4BilOROe EssoO oue Reading Date Gross Time Net Time Depth to Water Net Drop s (7;(7 ',vo ��o lZ 3lA• f? •2F:€7 7 f f7'1'5 -S 20 s PERCOLATION RATE Ta. - / (minmeynch) rtnc MULt uwdmt i to TEST RUN BETWEEN 5 FT AND Lo FT PERFORMED BY: /' ti I CERTIFYTHATTHIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: MUNICIPALITY OF ANCHORAGE �® Development Services Department .:,/ Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 011-122-84 1. GENERAL INFORMATION Complete legal description WARD LT 5 Expiration Date:0 5 d CQa Location (site address) 6963 PENNY ROSE CIR ANCH, AK Current property owner(s) Mailing address Real estate agent CLIFFORD & JENNIFER JOHNSON SAME 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone Day phone 3: NUMBER'OF BEDROOMS: 5 4. -TYPE OF WATER SUPPLY:' TYPE OF WASTEWATER DISPOSAL: Private Well [] Private Septic IX Wbter Storage ❑ Holding Tank ❑ Community Well ❑ Community [] Public Water System ❑X Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless othervnse requested by the engineer. COSA Fee $ 1 FJO (LD I 5 Waiver Fee $ Date of Payment to 13 %0 02 0 Date of Payment Receipt Number 0 13 4 t $ Receipt Number COSA# 0scaDI51 I Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm MIKE N ANDERSON, P.E. Phone 727-8864 Address 4661 NATRONA AVE ANCH AK Engineers Printed Name MIKE N ANDERSON, P.E. Date 10-4-20 S. DSD SIGNATURE System #1 Approved for 5 bedrooms System #2 Approved for _ bedrooms Disapproved 4 j ,� P I ;a: MICHAEL N• ANDEPaCN °C- P' )°CE 9 4 r9f Conditional approval for bedrooms, with the following stipulations: By; fi4 n 0 6a Original Certificate Date: 10 ,2 a2 oa v The Municipality of Anchorage Development Services Division (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA chocWisl bfuo sheet COSA Checklist Legal Description: WARD LT 5 If more than 1 septic system on lot: COSA Checklist # _of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Age of tank(s) 7 years Tank type/material Measured operating fluid level in septic tank 48 0 Standpipes/foundation cleanout per record drawing Date of pumping 10/5/20 D. ABSORPTION FIELD DATA Which system tested (date installed) 6/17/13 X ALL standpipes present per record drawing Total measured depth from grade 14.5 ft (max) Measured depth to pipe invert from grade 8.5 ft (min) ❑ N/A —pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective ParcellD: 011-122-84 Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes N No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by _ Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station _ years Lift station material _ Comments: Adequacy test date 10/5/20 Results [DPass For 5 bedrooms Fluid depth prior to test 0/1'� in Water added 750+ gal New depth 4/6 in Elapsed time 1440 min * Code -required soil cover over field Final fluid depth 1/� in ❑ System presoaked Absorption rate 750+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) If yes, enter date Gallons introduced gallons Comments/Deficiencies: ' MT at each end of the trench COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' v❑ Yes Community Sewer Manhole/Cleanout > 100' _ ft ❑ Yes if No _ ft ❑ Yes if No _ ft Neighboring Tank > 100' ❑ Yes if No _ ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No_ ft Holding Tank > 100' ❑ Yes if No It Neighboring Absorption Fields > 100' if No _ ft Animal Containment > 50' ❑ Yes if No ft ❑ Yes if No ft _ ft If septic tank is under driveway comment below _ Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑Yes if No _ ft ❑ Yes if No _ ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' v❑ Yes if No _ ft Surface Water > 100' Yes if No_ ft Property Line > 5' ❑v Yes if No _ ft Wells on Adjacent Lots: Absorption Field > 5' if No _ Yes if No _ ft Private Wells > 100' ❑✓ Yes if No _ ft Water Main > 10' ft Yes if No _ ft Community Wells > 200' 0 Yes if No _ ft Water Service Line > 10' ❑✓ Yes if No _ ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' v❑ Yes if No—ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No _ ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No _ ft Private Wells > 100' ❑v Yes if No _ It Water Service Line > 10'❑ Yes if No _ ft Community Wells > 200' ❑v Yes if No ft Surface Water > 100'✓❑ Yes if No _ ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet t .. °. ' t �•T MICHA€L N. ANDrRJCN•, CE 9469 �O\ a'r•�► Parcel I.D. 011-122-84 Municipality of Anchorage a On -Site Water and Wastewater Program 9 (907)343-7904 cserer Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description Ward, Lot 5 2. Expiration Date: S Location (site address) 6963 Penny Rose Circle Anchorage, AK Current Property owner(s) Merit Homes LLC Day phone 334-9233 Mailing address 1920 W. Dimond, Suite F Anchorage, AK 99515 Real Estate Agent Day phone S U is illi i 1 'y TYPE OF DWELLING: L (] Single Family (w/wo ADU) MAR 5 2014 I ❑ Duplex P .7 p ❑ Multiple Dwellings (Single Family and/or Duplex) I & , '" if i 3. NUMBER OF BEDROOMS: Five 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Pi Hir Wntar 53vctam n Waiver/Variance Received by: t Date: COSA to be released�to the engineer, unless otherMse requested by the engineer. COSA Fee $ Mpg •o V 4 q 1 .w Gush Waiver Fee $ Date of Payment 3� `J �1 y Date of Payment Receipt Number 61!1 l / Receipt Number COSA # __ 0,y,1 ,A 10 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system !slate) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Phone 522-7773 Engineer's Printed Name Michael E. Anderson, P.E. Date 3/4/2014 ...9 T H ! \� 6. DSD SIGNATURE rr, �6® "` ° PP . System #1 Approved for s bedrooms aaP System #2 Approved for bedrooms y - �. Disapproved °cam �rFESSI Conditional approval for bedrooms, with the following stipulations:'° :_ Original Certificate Date: �S l ii7 The Vqgiolpality of Anchorage Development Services Division (DSD) issues Certilicates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet t -- c If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Ward, Lot 5 A. WELL DATA AWWU Water System Well type If A, B, or C provide PWSID # Date completed Sanitary seal (Y/N) Total depth fL Cased to ft. FROM WELL LOG Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: B. SEPTICIHOLDING TANK DATA Parcel ID: 011-122-84 Well Log (YIN) Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION Collected by: ft. 16 Tank Type/Material Septic/Steel Dateinstalled 6/17/13 Tank size 1,500 gal. Number of Compartments 2 Cleanouts (YIN) Y Foundation cleanout (YIN) Y Depression over tank (YIN) N High water alarm (Y/N) Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA N Date installed 6117/13 Soil rating (g.p.d./ft' or ftz/bdrm) 1.0 GPD/SF System type Deep Trench Length 64 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth 14.5 ft. Eff. absorption area 768 fe Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fall) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump off' level at in. Datum Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Manhole/Access(Y/N) High water alarm level at Meets alar & circuit requirements? Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer /septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main Water service line >10 Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water Service line >10' Surface water >100' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS Lot is Served by AWWU Water System. G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 3/4/2014 COSA brown sheet_10-10-12.doo Absorption field >5' Surface water >100' Water main N/A Driveway, parking/vehiclestorage 0, ® IN RR . W dee ..s .............. 6 6 m : E. ANDERSON e ®Ii'. CE -4381 .^& in. 15' GAS ESMT PENNY ROSE CIRCLE 1 11=40' PIAT NO. 2006-13 Il/A P711 Poi 1r%r\ii GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, R.L.S. 2000 E. DOWLING RD., SUITE 8 ANCHORAGE, ALASKA 99507 PHONE 248-5454 GRID DATE SW2222 2/12/2014 F.B. JOB N0. 14-07 WARDS I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE: NO CORNERS SET THIS DATE sem; • ••� = 49TH • *•, ese •.••••. ........... •.: ••e•0 : Jeffery A. Gastaldt . oAIF N • L$�6091 e • '• `J♦♦ ® pla fe55ioflat �'��`e