HomeMy WebLinkAboutWARD LT 1Ward Lot 1 #011-122-80 Municipality of Anchorage Development Services Department Building Safety DMition Ne Onsite Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage. AK 99507 Page of www.cl.enchorage.ak us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW070244 PID Number. 011-122-80 Wastewater System: R1 New ❑ Upgrade ward Development iyaa. P.O. Box 91443 Anchorage, AK 99509 ABSORPTION FIELD pt,w,a 345-2122 Numbs of Bwaoam 3 9 Dw Tlwlal D Snrbw T. cl O SKI O Nana D Om 501 "aw7 Torr Depth Dan" acpnr pec• LEGAL DESCRIPTION .e GPo a 11 Ft. LDL glpyrlpw . DFpm b Poo Dawn"arla'nr p•a• Gr Will Dwwbt Pipe&aqi 1 Ward 5 Ft. 6 FL Townrp It" SFcban FII dada won Ong4pebe 0-1 Gnw LFrgn 50 Ft. Ft. Grnn.aal wabw a nyF OylarcF DFIwFarl Fne Well: ❑ New ❑ Upgrade 3 Ft. 1 FL Cy.Pnollan 1Pm'm A B. C) TOW own Cava b Tar bwpOrl O ASTM � 034 PVC AWWUWaterSystem FI. A F!' I Dow Dow ONOW. SWK Wow LM 011101W Cara Eye Excavatng DFte ftww 911=007 FL Yy Pyne Sn r c•>rro nDot. GrrFla TANK GPM FL FL SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding uDIIUPrivate •Oi••r Anchorage Tank Gap�T 1,000 Gr Fmm Tank Field Station Tank Sawa, Line msI 1MyFr a C011IpoMwly wr N/A NIA WA WA Steel Two (2) LIFT STATION Sunwywrw >700' >100' NIA N/A FfIJFr La ILy >10' WA N/A Gr 'Pyrp ai Ibwl K 'Pump ar rw aL Mpn wnw rrm K FowFDUI >g >10' N/A WA n n n Pump M"s i MOO" Eyeplrr Ind P� OT C~Dyn None Noted P•• BENCH MARK LOnpan ra pFapecn Garage Slab •vYIWII 100.0 FL 9/12M007 ��•V� Inspections performed by: A. Harala Dates: 1r ` •a`q�fj, y^a s112noo7 r ��Q=• Development Services Department Approval Conditional Approval Date: 0... 4.a.. ............. ..............e. MtOlAB ! ANDEit50N; v tr• ♦ "J : Cr•4381 •���� t�IfB � i; V Date: y PQOFESSIO��� o� �1J'L% .t/ � Reviewed and approved by: < rx.• owsi Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 PID No. 011-122-80 Permit Number. SW070244 N 89'51'06'E 133.97' E. ESiefT---- ----- — LOT 1 I I C5 �I WI All&emele I ''1 I n®z I Ad I TM1 1--: S2 C)1 S7 M B KW I g p ! I I w N Three Bedroom Home o0 NI I to o- 50 n I h I N A b 0 I , III 3sa 0 O Z 1 I b o S2 3oa c. 3+r +ea GRAVEL DRIVE I Z C5 N+' Bel M1 31.r 19, I I lelr I �II N I �o 1 1 I WARD SUBDIVISION 0 BRICK PA m i LOT 1 I B wi 40,168 S F. I 1 BLOCK WALL I I I I E3 OF 400 9' N 89'51'10'E 114.01' �j�, •i• 00,• O : 49th * •� — PENNY ROSE CIRCLE%." — — — ............. y 0 ; MICl1AEL E ANOERSW r L: • •�ci PLAN AS -BUILT •• -..-0... x- SCALE I' = 40' Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SW070244 96.0 N UU N N Septic Tank PID No. 011-122-80 or Note: 4" Wide Brick Landscaping Wall Around Perimeter of Drainfield Trench. Max. Height T2" Q 6'6" From Center of Trench. Height Varies from 0" to 2'2". PROFILE AS -BUILT No Scale 90.4 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK 99519.6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number. SW070244 PID No. 011-122-80 C5 P P Block Landscaping Wall M1 C4 TRENCH PLAN No Sale Landscaping Block Wall Fill 1.5' High 4'8' �_Drainfield Rock E OF ••••• •�� .%. •• z 49th !^� ;.....r ............. .... ...1... � ..., .rt .. ........ j '..MICHA0. L ANDERSON SECTION A-A •,. No, CE�38I •i ... -o.. •" � No Scale • •� •••�• � S ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 MEMORANDUM DATE: June 1, 2009 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 1, Ward Subdivision Septic System Inspection Report—SW070244 The following revisions have been made to the permit application for the septic system upgrade for the subject lot: 1. The absorption trench was originally designed to be constructed parallel with the contours of the ground surface. The surface was fully vegetated and treed during the design phase and the ground slope was less than 5%. When we arrived on site for the initial inspection the contractor had cleared the entire lot and slightly changed the contours of the surface slope to direct drainage to the northeast and provide slope for a detailed landscaping plan. The absorption trench was completely excavated and entirely within the 30' radius of the test hole. It was also completely within the percolation zone identified during the field design phase. The alignment of the trench was rotated approximately 20 degrees, but parallel to the ground surface contours as modified. The absorption trench was constructed in compliance with the Municipal ordinance and remains parallel to the ground surface contours. 2. The as built survey is signed by the surveyor. 3. The block wall is shown on the profile with photographs attached. 4. Swing ties have been corrected. 5. There is no ditch along Jodphur drive. 6. The COSA application has been corrected. 7. The COSA checklist has been corrected. Please advise if you have further comments regarding this inspection report. i ` �1�)��� � .• �t yea...• % --mdo • _ ..1 Z'� Y 1. / •i1 t• ,TY !V 1 ° '� r�r z Y♦ •r t y r Landscaping Wall Surrounding Absorption Trench •. i 1\ f < � P Y. • • ...i.. .[ ° .. i • 10, H • r r ' • .1 +"AL '� �,_ I 151•. . Y YQ wt MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Sep 12, 2007 Expiration Date: Sep 11, 2008 Permit Number: SW070244 Parcel ID: 011-122-80 Legal Description: WARD LOT 1 Design Engineer: 0014 ANDERSON ENGINEERING Site Address: NHN PENNY ROSE CIRCLE Owner Name: WARD DEVELOPMENT & CONSTRUCT Lot Size: 40168 SQ. FT. Owner Address: PO BOX 91443 Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99509 - This permit is for the construction of: ❑✓ Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received �� w Date: Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.orglonsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. 011-122-80 Property owner(s) Ward Development & Construction Management, Inc. Day phone 229-6529 Mailing P.O. Box 91443 Anchorage, AK Code 99509 Site address Kn Penny Rose Circle Zip Code Legal description (Sub'd., Block & Lot) Lot 1, Ward Subdivision Legal description (township, Range & Section) Lot Size 40.168 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field I] Septic Tank I] Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms Three (3) THIS APPLICATION IS AN: Initial Il Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number. (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 September 5, 2007 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Ward Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, Ward Subdivision intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The subdivision is served by the AWWU water system. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site. No existing wells or septic systems are closer than 100' from the proposed septic system. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the tract in the area of the absorption trench and alternate site indicated clean sand (SM/SP/SW) material with some silt. The percolation rate of the soil was determined to be from 6 to 15 minute per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000 -gallon septic tank and a 47' long by T wide by 6' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3.5' below the surface and the total depth will be 9.5'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench is nearly flat with a slight bias to the northwest at a grade of 2% to 5%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all Lot 1, Ward Subdivision September 5, 2007 Page Two wells and any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments I I I I I Im Hanks Subdivision VACANT Lot 2 40,262 sq.ft. VACANT us n -- S89'S1'10"W 329.76' - o -_--ROSE CIRCLE I 249.69' n __ 113_95' _ 134.00 _ ;2 00 13'36"E 5' Gas Esmt �' 50.03' 0' T&E Esmt VACANT I T C, 9 Lot 9 (A.0:u 40,155 a'- .. sq.ft. f° T� 10' Utility Esmtl—,, Drainage) Esmt , VACANT �' Lot 42,1344 \\\ sq.ft. i1i10 10' ME Esmt f2 VACANT us Lot 6 I 0 N +T >>0 0 D 03. Q E Y 45,681 ll0 sq.ft. P' " Ic0 ----'-------- 223.06'-----i-�c -- .���P(E,......,•,•41• Ratcliffe Subdivision ?��' _ ••. VACANT 1 1 3 :. 49th ':'� •• I 1 �........... ....... .j/f yy....� AREA PLAN • .' MIDNAEL E ANDERSON ,• C g •.Cid,% No. EE -381 f.�� • •'A 40 SCALE 1' = 100' •�4140�;;; , L W Of H N UP 50' F248-1 Eil246' ELEVATIONS BASED ON 1972 NGS DATUM (TYP) 255.4' O 249.4' _— PENNY ROSE CIRCLE SITE PLAN SCALE 1' = 40' WARD SUBDIVISION LOT 1 40,168 S.F. N 89'51'06'E 133.97' 10' T. k E. ESMT. ---------------- '-- I Ntemate 5'�te Lj W 4 i m I ® / r® THI {7' n x 3' Fide 6' x p I Mwrp .tim Tronch 30' / o ��y) 1.000 Galton r • Septic Tank n x i I I I Three Bedroom Home I I I I \ \ G. SLAB I I I EL 25 ' A.C. DRIVE I o I u n I x X 2 iI nn N v b n al z I Z I I i I z I I I i I I I N A9'S1'i OSE 114.01' 255.4' O 249.4' _— PENNY ROSE CIRCLE SITE PLAN SCALE 1' = 40' WARD SUBDIVISION LOT 1 40,168 S.F. LOT 1, WARD SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Deep Trench System Perc. Rate: 6-15 Min./Inch 1,000 Gallon Septic Tank Application Rate: .8 GPD/SF 6' Drainfield Rock 3 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 562.5 SF Absorption Area 562.5 SF/12 SF/LF = 46.88 LF Trench Length THEREFORE: Construct a 47' Long x 3' Wide x 6' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be 3.5' Below Original Ground Surface. Total Depth to be 9.5' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area. Natural Backfill 3'0" Geotextile ,�,--4Fabric 6" 4" Perforated PVC (Holes Down) 6'0" 3' I CAL CH Drainfield Rock (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. 2 3 4 5 6 7 8 9 IC I I 19 17 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM _ '4700 SOUTH BRAGAW ANCHORAGE, AK 99519 SOILS LOG - PERCOLATION TEST PROJECT #: PERFORMED FOR: LanTech Inc DATE PERFORMED: 2/16/05 LEGAL DESCRIPTION: Lot 1 Johnston Subdivision TEST HOLE # 1 SLOPE fiTilTiITJ➢ OG I I OL Some Roots A d N WAS GROUNDWATER ENCOUNTERED? NO S L IF YES, WHAT DEPTH? 0 DEPTH OF WATER - None P AFTER MONITORING: E DATE: 2/28/2005 P MMAEL C UDMON No. a4M •••aeee ROFESO i BOH 18' SITE PLAN N See Site Plan See Site Plan READING DATE GROSS TIME ... =.:.' SM NET DROP 12% - 15% Silt 14:12 5.88" Sand with Silt 1 14:22 10 7.13" 1.25" Recharge 14:24 O� o �E 5.88" 2 14:34 10 Z 1.19" •_ A d N WAS GROUNDWATER ENCOUNTERED? NO S L IF YES, WHAT DEPTH? 0 DEPTH OF WATER - None P AFTER MONITORING: E DATE: 2/28/2005 P MMAEL C UDMON No. a4M •••aeee ROFESO i BOH 18' SITE PLAN N See Site Plan See Site Plan READING DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP Start 2/20 14:12 5.88" 1 14:22 10 7.13" 1.25" Recharge 14:24 5.88" 2 14:34 10 7.06" 1.19" Recharge 1 14:36 5.88" 3 14:46 10 7.06" PERC RATE: 9.0 MIN./INCH PERC. HOLE DI'AMETER:6' TEST RUN BETWEEN 4.0 FT. AND 5.0 T. COMMENTS: Test Hole Pre Soaked Prior to Percolation Test. TEST PERFORMED BY: AH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/28/2005 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM 4700 SOUTH BRAGAW ANCHORAGE, AK 99519 SOILS LOG - PERCOLATION TEST PROJECT #: PERFORMED FOR: LanTech Inc DATE PERFORMED: 2/16/05 LEGAL DESCRIPTION: Lot 1 Johnston Subdivision TEST HOLE # 2 SLOPE SITE PLAN I .OG, I I Ir 3 4 5 6 FA s 12 17 OL Orange/Brown WAS GROUNDWATER ENCOUNTERED? NO S L IF YES, WHAT DEPTH? 0 DEPTH OF WATER None P AFTER MONITORING: E DATE: 2/28/2005 .. �I��j,No. a-4311 ••e� �v; 0 ES i swasso BOH 18' N See Site Plan See Site Plan READING DATE GROSS TIME ;:•:• GM/SM NET DROP Olive 14:18 Fine/Uniform Graded 6.25' Sand with Silt 1 Gravel with Silt 10 7.06" .81" Recharge 14:30 6.25' 2 •���� OF 10 7.06" .81" Recharge ;�... �• 6.25' i49thce_. a 3 ............. 10 7.06' WAS GROUNDWATER ENCOUNTERED? NO S L IF YES, WHAT DEPTH? 0 DEPTH OF WATER None P AFTER MONITORING: E DATE: 2/28/2005 .. �I��j,No. a-4311 ••e� �v; 0 ES i swasso BOH 18' N See Site Plan See Site Plan READING DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP Start 2/20 14:18 6.25' 1 14:28 10 7.06" .81" Recharge 14:30 6.25' 2 14:40 10 7.06" .81" Recharge 14:44 6.25' 3 14:54 10 7.06' PERC RATE: 120 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 4.0 FT. AND 5.0 T. COMMENTS: Test Hole Pre Soaked Prior to Percolation Test. TEST PERFORMED BY: AH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/28/2005 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program „ IT, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 011-122.80 COSA# P A 69_12,7 Expiration Date: 613�/D 1. GENERAL INFORMATION Complete legal description Lot t, ward subdivislon Location (site address) 7079 Penny Rose Circle Anchorage, AK 99502 Current Property owner(s) ward Development and construction Day phone 229-6529 Mailing address P.O. Box 91443 Anchorage, AK 99509 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Three (3) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site 0 Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System n Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-familyon-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined In the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 5/ =009 �o��•OF q4��t6 '.,' MKNML E ANDD-eoJ 4 6. DSD S)GNATURE I; s� CE -4381 •.!t; Approved for bedrooms. �� e, U! •.• E• Disapproved. f 1'14ld��s��a..'^'o Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory By: (Rw. nasi Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 1, ward Subdivision Parcel ID: 017.172-90 A. WELL DATA Well type AWWU Date completed _ Total depth ft. Date of test Static water level Well production If A. B, or C provide PWSID # _ Sanitary seal (YIN)_ Cased to ft. FROM WELL LOG ft. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic: _ ug/I Date of sample: _ B. SEPTIC/HOLDING TANK DATA Tank Type/Material SepNdsteei Tank size 1.000 gal. Number of Compartments Two Well Log (YM) Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION ft. Other bacteria Collected by: , colonies/100 mL Date installed 9/12/7007 Cleanouts(YIN) Y Foundation cleanout (YM) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping N/A Pumper New Construction C. ABSORPTION FIELD DATA, Date Installed 9/1=7 Soil rating (g.p.d./ft2 cr f?/bdrm).e GPD/SF System type Deep Trench Length 50 ft Width 3 ft. Gravel below pipe 6 ft. Total depth11-12 ft Eft. absorption area soo ftz Monftoring tube Y Depression over field N Date of adequacy test New Const. Results (PaswFail) For bedrooms Fluid depth In absorption field before test In. Water added gaL New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date Installed Size in gallons Manhole/Access (Y/N) 'Pump on' level at_ in. 'Pump off" level at _ in. High water alarm level at in. Datum Cycles tested Meets alar & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas None Manure/animal excrete storage areas None SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line IT Absorption field >5' Water main >70' Water service line 170' Surface water >100' Wells on adjacent lots >100• SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' Water Service line >10' Surface water >100, Driveway, parking/vehicle storage >25' Curtain drain None Noted Wells on adjacent lots >100• F. COMMENTS: Property is Served by AW WU Water System. G. ENGINEER'S CERTIFICATION l certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineers Printed Name Michael E. Anderson, P.E. Date 5115rzo09 COSA Fee $ A5 Date of Payment & 6 0 ci Receipt Number D -'q 666 (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number ►i41 A Ir.P'�dffS510�*��� R R si rIA Ia 0 50' 0 PLAT N0. 2006-13 WARD SUBDIVISION LOT 1 40,168 S.F. N 89.51'06"E 133.9T 10' T. & E. ESMT. ------------------ I I I t • I BLOCK WALL ~ 1 SEPi1C.SYSTEM C ^I I I I DUSTING BUILDING 16.3, 'D pnw GRAVEL DRIVE Ig BRICK PAVERS v BLOCK N 89.51'10"E 114.01' O M PENNY ROSE CIRCLE BRICK PAVERS 1111 BRICK PAVERS "r—� DECK r• 7.0- 5.0, _ ti`ryry O DECKO. 328' b d d 16.a a BUILDING DETAIL SCALE: 1"=20' o• a - - -- 13.5• - _ D' 12.3• b bCOVERED aENTRY e*• e� Q.. 6.01 DECK P n n AS—BU I I n GASTALDI LAND SURVEYING, LLC JEFF A. GASTAI.DI, R.LS. 2000 i- DOWUNO RD., SUITE E ANCHORAGE, ALASKA 99507 PHONE 248-5454 1.3• 1 11=40' °ECK I **1►\ IA� 0• 44 sw �.•'� 49Iti••.' 9 #0 or 0 6Hery A. Gasl0ldl .'os . LS -6091 �• .1 AN AV °a • .. p�•.. j> IGRID 2222 I D11/11/2008 F.B. I JOB NO. 08-09 1 WARD1 I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE: NO CORNERS SET THIS DATE.