Loading...
HomeMy WebLinkAboutWYATT LT 3Wyatt Lot 3 #051-221-05 MOA has confirmed that system has not been installed Jlayor.lark Begich 10/7/200.1 Ahmicipality of Anchorage ICO. Box IEXi(;7,0 • Andhomgc, Alaska SY,)519difM 0 7dcphonc (4X)7) 343.13;301 • Fac (907) 343.(a(X) • ' ' 37(X) Bragaw• 5trcct • Anchomgc, Alaska 99507 nsme.mnni.ngr Difl](tln.g Snfcty Division Mike Polyefko 14911 West Lakeridge Drive Eagle River, AK 99577 Subject: Expired On -Site Water and/or Wastewater Permit. Permit Number: SW030007 Legal Description: Wyatt Lot 3 Dear Mr. Polyefko: An On -Site Water/Wastewater Permit, number SW030007 issued by this office for a single-family system, expired on January 09, 2004. The permit %vas valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, otc Daniel J. Roth Manager On -Site Water and Wastewater Program Enc: Copy of permit Conintunity, Security, Prosperity MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bregaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW030007 [LegaiDescription WYATTLT 3.i Design Engineer: 0070 KND Engineering Owner Name: MIKE POLYEFKO Owner Address: 14911 WEST LAKERIDGE DRIVE EAGLE RIVER. AK 99577 - Date Issued: Jan 09, 2003 Expiration Date: Jan 09, 2004 Parcel ID: 051-221-05 Site Address: Lot Size: 10275 SO. FT. Total Bedrooms: 2 Permit Bedrooms: 2 This permit is for the construction of: [l Disposal Field [?] Septic Tank Ej Holding Tank ❑ Privy ❑ Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. ONLY A CERTIFIED CONTRACTOR CAN CONSTRUCT THIS ADVANTEX ALTERNATIVE WASTEWATER DISPOSAL SYSTEM. Received By: Issued By: Date: Date: 9 Z0,3 Municipality of Anchorage Development Services Department •'� `' °' Building Safety Division 11-. On -Site Water and Wastewater Program ' 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. DSI — 2 21 - 01 Permit Number SW 030007 Property owner(s) Mike Polyefko Mailing address (1) 14911 W- Lakeridge Drive. Dayphone 696-0658 -River- AK 99577 Mailing address (2) -Eagle Zip Code Legal description (Lot, Block & Sub d) Wyatt Lets 2 & 3 Legal description (Section, Township & Range) Lot Size 10275' Acre q.F Number of Bedrooms 2 THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit Therapy Pool ❑ 1 certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: SSD Waiver Fees: Date of Payment: /2f�l Z Date of Payment: Receipt Number: 2-92711 Receipt Number: (Rev. 12/00) ACITNIDENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-8111 December 17, 2002 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer/water storage permit— Wyatt Subdivision Lots 2 & 3 Gentlemen: The owner has requested we proceed forward to obtain a septic/water storage permit on the subject lots. On December 2, 2002 one testhole was performed on Lot 3 for the proposed system. The results of this test are attached. The general slope of this lot is from southeast to northwest at a grade of approximately 3-8%. We have designed our system utilizing the existing testhole that was excavated for the existing 2 -bedroom house on Lot 2. We propose to install an AdvanTex Orenco Package System. This system will be manufactured by Anchorage Tank & Welding to meet Orenco Systems, Inc. latest design criteria and in accordance to MOA requirements. The Drainfield Design is based on the following: • 2 -Bedroom Design Flow: 300 gpd • Percolation Rate: <1 min/inch • Application Rate: 3 gpd/sf • Minimum Absorption Area: 100 sf • Effective Absorption Area: 100 sf (5' wide by 20' long) • Effective Depth Below Pressurized Distribution Pipes: 0.5' Potable water for an individual storage tank will serve Lot 2, located in the crawl space. We propose to install one 5' wide shallow trench. Water was encountered during the excavation at 5', and during monitoring at 6.2'. The owner, Mike Polyefko, owns Wyatt Lots 2, 3, 4, 5 & 6. Mr. Poly efko will execute an ingress and egress easement to accommodate the septic system on Lot 3, which as proposed will serve the 2 -bedroom house on Lot 2. Subject* Wyatt Lots 2 & 3 December ]7, 2002 Page 2 of 2 There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, >IiI�I� Engineering, Inc. Kenneth M. Duffus, P.E. Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/STTF Pi o DESIGN D TAI Ci 2 BDRM X 150 GPD = 300 GPD APPLICATION RATE= 3 GAL/DAY/SQ.FT, MIN. ABSORPTION AREA= (300 GPD/3 GPD/SOFT)=100 100 SOFT. / 5 FT. WIDE = 20 FT TRENCH USE 1 TRENCH 5' W x 20' L x ,5' D TOTAL DEPTH OF EXCAVATION IS 2'. ADD 2' SAND LAYER BELOW FIELD TOTAL EFFECTIVE DEPTH IS 0.5'. ORENCO PACKAGE SY T Mi 1. INSTALL S.T.E.P. TANK W/ INTEGRATED ADVANTEX TANK WILL BE SIZED PER ANCHORAGE TANK FOR 2. INSULATE TANK, EXCEPT BELOW ADVANTEX PADS 3. NO AIR LINE REQUIRED. TO PUBLIC YELLS VTTHIN ear OF PROPOSED SYSTEM IO PRIVATE VELLS MIND/ Epp• 6' PROPOSED SYSTEM EXCEPT AS NOTED, NO SEPTIC SYSTEMS WRMiN Ear OF PROPOSED YELL EXCEPT AS NOTED. SOFT, SYSTEM, A 2 BDRM RESIDENCE. TO ALLOW HEAT TRANSFERENCE. NOTESi 1. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 2. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 3. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. PREPARED FORT MIKE POLYEFKO 14911 V. LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 868-3793 FlELO BOOKS EouoARr. SFWAF STAW -- ASM r. Dm me ACRD ESE: CONFUTED: DRAM CHECKM ATCcmDATE--- cm " "- 02087 Scales 1'= 100' PAGE 1 OF 4 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 11 WASTEWATER DISP❑SAL SYSTEM DETAILS WYATT SUBDIVISION LOT 2 AND 3 V� �9 K L CO 11 d- 0 6' PROPOSED AX -10 SEF LOT 55' DVANTEX 3 PREPARED FORT MIKE POLYEFKO 14911 W. LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 868-3793 FIELD BOOKS Bawun: _EWAF IRS -- wMnr. -- V a nc ACRD nE• ,..,,,e-. tommim[ MAW VBG p10� KMD CATS: 12/17 0m. NW105 02087 1 EXISTING BDRM HOU FCO Scales 1'= 20, PAGE 2 OF 4 LLS.1V LW ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 1 WASTEWATER DISPOSAL SYSTEM DETAILS WYATT SUBDIVISI❑N LOT 3 4' MON 4' MONITORING TUBE 311 SLOPE MAX FINAL GRADE PLYWOOD BARRIER — AROUND TRENCH ORIGINAL GRADE BRACING AS NEEDED 2.0' DEEP REMOVE ALL ORGANICS r4' CLEANOUT +� FINSULATION r -FILTER FABRIC WIDE 2' MIN COVER FINAL GRADE ORIGINAL GRADE SEWER ROCK 2' MIN M.O.A. APPROVED SAND FILTER PROFILE VIEW LEACHFIFLD D TAI S NOTE, BOTTOM OF SEWER DRAINROCK MUST BE 4+ FEET ABOVE GROUNDWATER AND 6+ FEET ABOVE BEDROCK, PREPARED FORT MIKE POLYEFKO 14911 W LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 696-0858 FlEU) BOOKS em*o " - SEWAR STA'O'a STAKIN Awn ASBUIL Cm nE Auo nn 02087. Calpom: MAW: BMW O0'm KMD DAIS 12/24 pm NW105 02087 Scales NTS PAGE 3 OF 4 LL\�d\a LW ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 11 AdvanTex Treatment System AX' 10 Series - Mode Ib Inlet—. - 2' Di Inlet Inlet - View Discharge Pump Basin Discharge roMe Ipening .i ��.�F'.41 % 4*' �r9 /. *.... T....... .'.. * .0 '. KENNETH Y. `1 CE -7116 AfF '•�u'ESSIO� I Side View PREPARED FOR, MIKE POLYEFKO 14911 W. LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 868-3793 FlnD BOOKS ea,srDARY: WAF STMMG: -- ASD 1 _— D■a nt AM ME, nnna� ca"vuaD: MAM: VBG C"ECKM. KMO DAM 12/17 GRV. NW105 JD8 "' 02087 scale r NTS PAGE 4 OF 4 scale r NTS L❑CATION OF PROPERTY, WYATT SUBD LOT 2 AND 3 141d�i!!1J ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 ITYD ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST Performed for: Mike Polyefko Date Project:_ Wyatt Lot 3 TEST HOLE N 2002-01 Depth 11- 12- 13- 14- 15- 16- 17- 18- 19 - ORG/OL—black peat and red/brown overburden seeps GP/SP—brown/red, damp sandy gravel B.O.H. HOLE• PRESOAKED 20- PRIOR TO TEST SEE ATTACHED S=PLANFOR HOLE LOC Was Cround water encountered? YES What depth? 5' Depth to water after monitoring? 6.2' Date? 12/9/02 Reading Date Gross Time Net Time Depth to Water Net Drop 1 12/02/02 1:00 6" _ 2 1:05 5 min dry 6" 3 ' 1:06 6" - 4 1:11 5 min dry 6" 5 " 1:12 6„ - 6 1:17 5 min dry 6" 7 1:18 6" - 8 1:23 5 min dry 6" 9 124 6" _ 10 1:29 5 min dry 6" 11 1:30 6'• _ 12 1:35 5 min d 6" " Water Added Percolation Rate- 1 (min/in) Perc Hole Diameter 6" Test Run Between 2.5 feet and 3.5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. ®2002-099921-0 Recording Dist: 301 -Anchorage A 12/27/2002 2:11 PM Pages: 1 of 8 K �IIIIIIIIIIIIIIIINIIIgIIINIINIIIIIIIINIIII�nllllBl�llnll A GRANT made this day of a eA �Ca'J2 ,between m, t t 1'0�� e��io of y9// ' ,Anchorage, AK 9srJ? hereinafter referred to as the Grantor, and Arlt of 151fll W, w.ec I%l L1f , Anchorage, AK99s97 , hereinafter referred to as the Grantee. WHEREAS, the Grantor is the owner in fee simple of the following described realty: Wyatt Lot 3, according to the official Plat thereof, filed as Plat P-- I M in the Anchorage Recording District, Third Judicial District, State of Alaska, and, WHEREAS, the Grantee is desirous of enjoying the use of a certain portion of the Grantor's land for the sole purpose of ingress and egress to Grantee's land for the purpose of installing and maintaining a private septic system, and, WHEREAS, the Grantor has agreed, in consideration of $10.00 (Ten Dollars and No Cents) and other good and valuable consideration, the receipt of which by Grantor is hereby acknowledged, to grant to the Grantee an easement solely for said defined purposes and no other, NOW this grant witnesseth that in return said specified consideration paid by the Grantee to the Grantor, the Grantor hereby grants unto the Grantee, his heirs and assigns, full and free right and authority to install and thereafter maintain a private septic system with septic reserve upon a portion of Grantor's land as shown by the "WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN" by Kenneth M. Duffus, P.E. dated December 17, 2002. This Grant of Easement is intended to be appurtenant to Grantee's above-described land and touches, concerns and runs with said lands. This is not intended to be an exclusive easement: the Grantor herein expressly reserves unto himself equal rights of ingress and egress and all other rights as the owner in fee simple of the described premises. 1 Michael J Polyefko 14911 W. Lake Ridge Dr. Eagle River AK 99577 Home Phone 907-696-0858 To whom concerned, December 10, 2002 I Mike Polyelko have over twenty five year experience in the excavation business in the anchorage area, 1 will do the install of the sewer in Wyatt sub. lot 2 & 3, I have all my own equipment to do the job. Sin ely, Mi a Polyelko STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES ANCHORAGE RECORDER'S OFFICE 550 W 7TH AVE SUITE 1200 ANCHORAGE AK 99501-3564 (907) 269-8899 REC DATE RECEIPT NUMBER 12/27/2002 1827978 RECEIPT DESCRIPTION RECORDERS OFFICE FEE BANK CD/CK NUMBER: 7950 RECORDING RECEIPT AMOUNT: 538.00 SERIAL NUMBER INFORMATION YEAR:2002 BEGINNING NUMBER : 99921 ENDING NUMBER : 99921 TOTAL PAGES : 8 RECORDING FEES COPY FEES PLAT FEES PLAT COPY FEES NON REFUNDABLE OTHER FEES MICROFICHE COPY FEES $36.00 FILING FEES CONFORMED COPY FEES $2.00 CERTIFICATION FEES OVER SIX NAMES FEES COPY SEARCH FEES INFORMATION SEARCH FEES REMITTER: MIKE POLYEFKO 14911 W.LAKERIDGE DR EAGLE RIVER AK 99577 COMMENTS: RECEIPT - DO NOT PAY NOTE: ORIGINAL RECORDED DOCUMENTS WILL BE RETURNED FROM MICROFILMING IN 4-6 WEEKS. If Public water and sewer become available or the subject encroaching septic system is identified as in failure and cannot obtain a Municipal of Anchorage Health Authority Certificate, this easement becomes null and void and Grantee will abandon the encroaching system and connect to the public utilities or install a legal system on Grantee's property, 3 w y A Sti ✓ib�.uv Any dispute or disagreement arising under or in any way concerning this instrument shall be submitted for resolution to the process of binding arbitration in accordance with the Alaska Statutes made and provided for said arbitration. The jurisdiction of the Arbitrator shall commence 60 days from the onset of the dispute and shall operate to toll all applicable Statutes of Limitation. In WITNESS WHEREOF the Grantor and Grantee have hereunto set their hands the day and year first above written. STATE OF ALASKA ) THIRD JUDICIAL DISTRICT ) THIS IS TO CERTIFY that on this day 1 day of OIL.= - before me the undersigned, a Notary Public in and for the State of Alaska, duly commissioned and sworn, personally appeared Tn %.yz�Q t'-pf< 0 �IIIIIIIIIIIIII'IIII�IIllllll 2 2002-099921-0 To me known to be the person described in and who executed the above foregoing instrument, and acknowledged to me that %A_ signed and sealed the same freely and voluntarily for the uses and purposes therein mentioned. WITNESS my hand and official seal the day and year in this certificate first above written. STATE OF ALASKA ) THIRD JUDICIAL DISTRICT ) 4 � Ulu - Notary Public in and for Naska _ My commission expires THIS IS TO CERTIFY that on this day day of , before me the undersigned, a Notary Public in and for the State of Alaska, duly commissioned and sworn, personally appeared To me known to be the person described in and who executed the above foregoing instrument, and acknowledged to me that _ signed and sealed the same freely and voluntarily for the uses and purposes therein mentioned. WITNESS my hand and official seal the day and year in this certificate first above written. A�L AW 40 K: L Poly-ealo ANSI/ w Aaje." 4-V .0/I. roz/ Ai t2 Ak 9s'f77 Notary Public in and for Alaska My commission expires: �IIIIIIII�III IIiIIII�II�I�I 3 2002-099921-0 LL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAP DESIGN DETAILSI 5 2 BDRM X 150 GPD a 300 GPD C, APPLICATION RATEv, 3 GAL/DAY/SQ.FT. moo MIN. ABSORPTION AREA= (300 GPD/3 GPD/SOFT)=100 SOFT. 100 SOFT. / 5 FT. WIDE = 20 FT TRENCH USE I TRENCH 5' W x 20' L x .5' 3) TOTAL DEPTH OF EXCAVATION IS 2'. -- ADD 2' SAND LAYER BELOW FIELD �— TOTAL EFFECTIVE DEPTH IS 0.5'. OR N -❑ PACKAGE SYSTEM, 1. INSTALL S.T.E.P. TANK W/ INTEGRATED ADVANTEX SYSTEM, TANK WILL BE SIZED PER ANCHORAGE TANK FOR A 2 BDRM RESIDENCE. 2. INSULATE TANK, EXCEPT BELOW ADVANTEX PADS TO ALLOW HEAT TRANSFERENCE. 3. NO AIR LINE REQUIRED. MCI POKIC VELI: VTTIDM too• w PROPOSED SYSTEM. Ill P ATE WELLS VITHIM EDP 6 PRWUSED SYSTEM ESCVT AS NOTED. Io SEPTIC SYSTEMS Vmml tDv OF PRlPOSED WELL EXCEPT AS NOTELL AV ��' OF•"„S�i ..-Y1All ; ssle Aw NOTES, 1. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 2. CONTRACTOR WILL ENSURE MINIMUM 27 SLOPE INTO SEPTIC TANK. 3. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. PREPARED FOR, MIKE POLYEFKO 14911 W. LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 868-3793 FIELD BOOKS COMPVT e Douawr. SEWARD mm SrA -- acaam AMMIt DAM DW*. mm cm 1G1D 1E8 02087.DWGI "N" 02087 Scalel 1'= 100' PAGE 1 OF 4 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 WASTEWATER DISPOSAL SYSTEM WYATT SUBDIVISION LOT 2 AND 3 V� \ L� KND L DETAILS 1 n � 0 O 6' ° 10 ���M -l� Qpcj�O � 55' EXISTING �O CO �Q 2 BDRM HOUS p� PROPOSED DVANTEX pQ FCO AX -10 SERI o �8 0 0 LOT 3 %�4�•OF•A��1� f PREPARED FOR, MIKE PDLYEFK0 14911 W. LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 868-3793 6 of B 2002-099921-0 Scales 1'= 20' PAGE 2 OF 4 FlE1D Boats oowTm END ENGINEERING swouir: SEWARD Maws IT/11Q -- °1EO®' KMD 20441 PTARMIGAN BLVD. ASKXn__ wm EAGLE RIVER, AK 99577-8736 ow¢ I'm aim NW1057 ::.::.......,...,...:.:: Am M`02087.DWG AeN- 020871(907)696-6111/FAX (907)606-811i WASTEWATER DISPOSAL SYSTEM DETAILS WYATT SUBDIVISI❑N LOT 3 4' MON toms ATVA\ITrV 4' MONITORING TUBE ,1 SLOpE NAX FIpAI- GRADE 3 AROUND TR NCHER — ORIGINAL GRADE BRACING AS 2.0' DEEP REMOVE ALL ORGANICS r4' CLEANOUT ,TER FABRIC 2' MIN COVER FINAL GRADE ORIGINAL GRADE SEWER ROCK 2' MIN M.O.A. APPROVED 5' WIDE SAND FILTER 5 �m PROFILE VIEW = o Q lEAGHFIELD DETAILS =w NOTES BOTTOM OF SEWER DRAINROCK MUST BE 4+ FEET �� c ABOVE GROUNDWATER AND 6+ FEET ABOVE BEDROCK. PREPARED FOR, MIKE POLYEFKO 14911 W LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 696-0858 FlEU) BOOKS B ICA0.1R SEWAR RA1°'Q STAKIN Asft&y'- ASBUI ora M Am ^'L* 02087 001Wime MAW BMW 0*"m KMD DAM 12/24. pD NW105 02087 Scales NTS PAGE 3 OF 4 LL&LN1IW ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER,.AK 99577-8736 1 AdvanTex Treatment System AX 10 Series - Mode lb Inlet Top View D6cMnp Pump &nIn Dpwn9 Side View PREPARED FOR, HIKE POLYEFKO 14911 W. LAKERIDGE DR. EAGLE RIVER, AK. 99577 (907) 868-3793 FIELD BOOKS 001"A". SEWAF ETAOO -- Asoxin -- Dra ME: ACM IxE: nl)na-1 compv,m: DRANKyeG affaam KMD DATe 12/17, cm NW105 jm *- 02087 PAGE 4 OF 4 scale 1 NTS A scale 1 NTS L❑CATI❑N OF PROPERTY, WYATT SUBD LOT 2 AND 3 R&N W) ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 1 11 Municipality of Anchorage ., Development Services Department ar Building Safety Division y ; On•SiteWater and Wastewater Progrant SA IT, 4700 Bragaw Street p.0. Box 196650 Anchorage, AK 99519-6650 www.danchorage.skus (907)343.7904 PROPERTY OWNER AGREEMENT FOR THE MAINTENANCE OF AN ON-SITE WASTEWATER DISPOSAL SYSTEM This agreement, dated `� – lL,, 2CvL, is made between the Municipality of Anchorage Development Services Department (DSD) and the property owner(s) of. , << vJvu This agreement is made for the purpose of maintaining an on-site wastewater disposal system on the subject property. The property owners agree to the following: Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation statement from a registered professional engineer. This inspection and operation statement shall verifythat the engine r has ins ect d 1 effluent and air pumps, timers, and alarms, and that any defiencies have 0 repaired gat the system is functioning as designed. (Signature) e�4 .ON PQ IV (Printed ame) (Printed Name) The Foregoing Instrument was acknowledged bfore me by Q— on this �Lay of 20 Or? - Wit s my hand and sea \�"QJ " • k Notary Public (Signature) NOTARS 111 zi PUBLIC (Notary's printed name) My Commission Expires U OF II IINII I� Iaillllll I II a of 9 2002-099921-0 Municipality of Anchorage �• �- Development Services Department IBuilding Safety Division i On -Site Water and Wastewater Program s r 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: KND ENGINEERING Legal description: WYATT SUBDIVISION LOT 3 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. ❑ Additional soils information needed. ® Water monitoring results inadequate. SYSTEM MUST BE 5 FT. FROM THE WATER TABLE MONITORED IN DECEMBER THUS EXCAVATION DEPTH SHOULD BE MAX OF 2 FEET AND MINIMUM OF 2 FEET OF APPROVED SAND ❑ Discrepancy in information submitted. ❑ Topographic information missing or inadequate. ® Incomplete; missing NEED INGRESS/EGRESS EASEMENT NOW ❑ Incomplete; missing ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field. ® Other. 1.) AT THIS TIME ONLY CERTIFIED EXCAVATORS CAN INSTALL THE ADVANTEX SYSTEM Name of reviewer: DAN Date: 12/23/02 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK