June 17, 1997
Daniel B Robertson
Heather Hearine
4751 Mars Drive
Anchorage, Alaska 99507 3724
Subject: Lot 1 Snowline Terrace Subdivision
Permit #SW960121, PID X1015-163-62
The subject permit, issued June 14, 1996 by this office for a
single family well and/or on-site wastewater system, has
expired as of June 14, 1997.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as -built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
,S
I'll
rely,
J mes Cross, P.E.
Program Manager
On-site Services
enc: Copy of Permit
cc: KND Engineering
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL
PERMIT NUMBER:SW960121
DESIGN ENGINEER:KND ENGINEERING
OWNER NAME:DAN ROBERTSON
OWNER ADDRESS:4751 MARS DR.
ANCHORAGE, ALASKA 99507
PARCEL ID:01516362
LEGAL DESCRIPTION:
SNOWLINE TERRACE LT 1
LOT SIZE: 49435 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
//PAGE 1 OF 1
( l
SYSTEM PERMIT �, �Y'V�
l a_C� _cl
DATE ISSUED: 6/14/96
EXPIRATION DATE: 6/14/97
A 3t�
1'-�CAA-� (.'�
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
PROVIDE DOCUMENTATION REGARDING TYPE -OF
DIVERTER VALVE AND SUBMIT WITH ASBUILT.
RECEIVED B
ISSUED BY:
DATE:
DATE: 6('111117,1
XND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)696-6111/FAX (907)696-8111
June 3, 1996
Municipality of Anchorage
Dept. of Health & Human Services
On -Site Services Section
P. O. Box 6650
Anchorage, Alaska 99519-6650
Subject: Lot 1, Snowline S/D - Sewer/Water permit
Gentlemen:
We have performed two soil tests on the above property in preparation for the installation
of a new system to serve the proposed four bedroom dwelling. Upon initial testing we
found water seeping into the testholes during what we believe was high seasonal water.
After a week, there was no water in either testhole. However, our design is based on the
higher reading.
This lot contains two areas which appear at first to be drainages. These areas were
monitored during several months this spring, and in fact only the northern one was wet
in the spring. It dried up completely during breakup and is not expected to pose a surface
water problem. The other area remained totally dry.
The well for this property will be sited near the northeast property corner, thus allowing
the system to be placed toward Snowline Drive. We anticipate construction of both the
primary and reserve fields at the same time, including the installation of a diverter. There
is a gentle slope from the east to west on this lot; additional fill will be placed over the
trench after construction. The development of this lot poses no adverse effect on lots
surrounding it. l
If you have any questions about this application, please call me at 696-6111 /FAX 696-8111.
Respectfully submitted,
KHD Engineering
Kenneth M. Duffus, P.E.
attachments: On -Site Well and Sewer Application
Wastewater Absorption System Details
Site Plan
Soils Log/Percolation Test
I
SEPTIC AREA
SITE PLAN
WASTEWATER DISP❑SAL SYSTEM
LOT 1, SN❑WLINE S/D P.I.D,
/ 1Q
. N m9fJY W (H CO
• PROPOSED WELL
WELL
• I
± 4 HD
OF A,,,
�.*...9TH f
I� KENNETH M. D S /
CE -7116 4
Www/
p�FESSI0I5A�' ./
16A8Y
WITHIN 200' OF SEPTIC SYSTEM
CO V ��• TH2
MT 70' Co
� a
a
DIVERTER''
p SEPI
R
11' 1 1 11.1
N mm'JY w 0 mm'As' w Iss.laT 165m'
Ioi SNOWLINE DRIVE
NO WELLS WITHIN 200' OF SEPTIC SYSTEM
FOR:
DAN ROBERTSON
4751 MARS
ANCHORAGE, ALASKA 99507
KND ENGINEERING
20441 PTARMIGAN BLVD
EAGLE RIVER, AK, 99577
(907)696-6111/Fax (907)696-8111
DATD 6-1-96 DRAWING N
SCALE: 1' = 100' 96011-S1
DESIGN DETAILS
WASTEWATER ABS❑RPTI❑N SYSTEM
LOT 1, SN❑WLINE S/D
00 0 0 0
U U U U OU U £ O
1250 GAL
SEPTIC
5' MIN.
T TO 4' SOLID FROM HOUSE
Q M.T.
FINISHED GRADE/ORIGINAL GRADE 1.5' LOWER
UNCLASSIFIED FILL FROM EXCAVATI❑N
2" HD INSULAT
CONNECT TO 4' SOLID FROM HOUSE
C.O.
O C.O.
O C.O.
C.O.
C.O.
70'
CONNECT TO RESERVE FIELD
OF AZ
KENNETH
t
1 `ted
p7''CFESSIOIS
ILTER FABRIC
SCREENED ROCK
70'
0.5'
N
TOTAL EXCAVATI❑N DEPTH FROM ORIGINAL GRADE 4'
WATER OBSERVED AT 8'
-T-
DESIGN
DESIGN DETAILS
1. 4 BDRMS X 150 GPD = 600 GPD.
2. 600 GPD/1.2 GPD PER SQ. FT. = 500 SQ. FT.
3. 500 SQ. FT./5 ' WIDE X .70 R. F. FOR 2' = 70'
4. USE TRENCH 70' L, 5' W, 2' GRAVEL
5, TOTAL DEPTH OF SYSTEM WILL BE 4.0' BELOW ORIGINAL
GRADE,
6. 2' HD INSULATION TO BE INSTALLED OVER
FIELD AND SEPTIC TANK,
7. CONTRACTOR TO VERIFY AND INSURE 27 GRADE FROM HOUSE.
8. CONSTRUCT PRIMARY & RESERVE FIELDS AT THE SAME TIME.
CONNECT TO PROPOSED DIVERTER.
': 'A: 1 -'
DAN ROBERTSON
4751 MARS
ANCHORAGE, ALASKA
KND ENGINEERING
20441 PTARMIGAN BLVD
EAGLE RIVER, AK, 99577
(907)696-6111/Fax (907)696-8111
99507 DATE: 6-1-96 DRAWING #
SCALES NTS 96011-52
Municipality of Anchorage
t DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: &obef A912 DATE PERF
LEGAL DESCRIPTION: p7 S/�OI�J�/%C�i d/ice Township, Range, Section: �y#
DEPTH SLOPE SITE PLAN
(FEET) �P16w
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COMMENTS
w�Cod��cs
l'aM/YSa ,121
M
WAS GROUND WATER
ENCOUNTERED? j'es
S
L
D
P
E
S2/ 9
IF YES, AT WHAT
DEPTH?
Depth to Water After
Monitoring? /5, Date:
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
.5 /3
G;3
—
G •
—
I
: yo
3y.
-
Z
Lo:yZ
r i
J 3f3"
7
3
:,13
7/&
wu r61
Z16
—
z
S
nirl
�31g'
k
yg„
PERCOLATION RATE_L_L L (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN V FT AND J FT
PERFORMED BY: "Z) CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: TA6
72-008 (Rev. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
�/
/ /!� 'rutESSivs
PERFORMED FOR: xxeD _-z/SO DATE PERFORMED:
// C �
LEGAL DESCRIPTION: C-l��� ✓/")D/•!!�/%P� S�� Township, Range, Section:
FJ
DEPTH SLOPE SITE
SITE PLAN
(FEET) I I
1
2 —
3-
4
5
6-
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COMMENTS
DG
12Caid' 19
S���rGveL
WAS GROUND WATER
ENCOUNTERED?
S
L
O
P
E
2/
IF YES, AT WHAT
DEPTH?
-'eb Depth to Water After
Monitoring? Date:
®®®®
Depth
•••:.a tia :a
na an as. •°s
0�Y
e
=12=105�r�r�r�s����
�/
/ /!� 'rutESSivs
PERFORMED FOR: xxeD _-z/SO DATE PERFORMED:
// C �
LEGAL DESCRIPTION: C-l��� ✓/")D/•!!�/%P� S�� Township, Range, Section:
FJ
DEPTH SLOPE SITE
SITE PLAN
(FEET) I I
1
2 —
3-
4
5
6-
7
8
9
10
11
12
13
14
15
16
17
18
19
20
COMMENTS
DG
12Caid' 19
S���rGveL
WAS GROUND WATER
ENCOUNTERED?
S
L
O
P
E
2/
IF YES, AT WHAT
DEPTH?
-'eb Depth to Water After
Monitoring? Date:
®®®®
Depth
=12=105�r�r�r�s����
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND - FT
PERFORMED BY: IfIlOd f I �P12 Dfie CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MU CIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: