Loading...
HomeMy WebLinkAboutSNOWLINE TERRACE LT 1�rwwL.n�. �ItrracL kA I ® Municipality ®f Anchorage Department of Health and Human Services Fj 825 "L" Street Rick Mystrom, Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 June 17, 1997 Daniel B Robertson Heather Hearine 4751 Mars Drive Anchorage, Alaska 99507 3724 Subject: Lot 1 Snowline Terrace Subdivision Permit #SW960121, PID X1015-163-62 The subject permit, issued June 14, 1996 by this office for a single family well and/or on-site wastewater system, has expired as of June 14, 1997. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as -built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. ,S I'll rely, J mes Cross, P.E. Program Manager On-site Services enc: Copy of Permit cc: KND Engineering MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL PERMIT NUMBER:SW960121 DESIGN ENGINEER:KND ENGINEERING OWNER NAME:DAN ROBERTSON OWNER ADDRESS:4751 MARS DR. ANCHORAGE, ALASKA 99507 PARCEL ID:01516362 LEGAL DESCRIPTION: SNOWLINE TERRACE LT 1 LOT SIZE: 49435 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: //PAGE 1 OF 1 ( l SYSTEM PERMIT �, �Y'V� l a_C� _cl DATE ISSUED: 6/14/96 EXPIRATION DATE: 6/14/97 A 3t� 1'-�CAA-� (.'� 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: PROVIDE DOCUMENTATION REGARDING TYPE -OF DIVERTER VALVE AND SUBMIT WITH ASBUILT. RECEIVED B ISSUED BY: DATE: DATE: 6('111117,1 XND ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 June 3, 1996 Municipality of Anchorage Dept. of Health & Human Services On -Site Services Section P. O. Box 6650 Anchorage, Alaska 99519-6650 Subject: Lot 1, Snowline S/D - Sewer/Water permit Gentlemen: We have performed two soil tests on the above property in preparation for the installation of a new system to serve the proposed four bedroom dwelling. Upon initial testing we found water seeping into the testholes during what we believe was high seasonal water. After a week, there was no water in either testhole. However, our design is based on the higher reading. This lot contains two areas which appear at first to be drainages. These areas were monitored during several months this spring, and in fact only the northern one was wet in the spring. It dried up completely during breakup and is not expected to pose a surface water problem. The other area remained totally dry. The well for this property will be sited near the northeast property corner, thus allowing the system to be placed toward Snowline Drive. We anticipate construction of both the primary and reserve fields at the same time, including the installation of a diverter. There is a gentle slope from the east to west on this lot; additional fill will be placed over the trench after construction. The development of this lot poses no adverse effect on lots surrounding it. l If you have any questions about this application, please call me at 696-6111 /FAX 696-8111. Respectfully submitted, KHD Engineering Kenneth M. Duffus, P.E. attachments: On -Site Well and Sewer Application Wastewater Absorption System Details Site Plan Soils Log/Percolation Test I SEPTIC AREA SITE PLAN WASTEWATER DISP❑SAL SYSTEM LOT 1, SN❑WLINE S/D P.I.D, / 1Q . N m9fJY W (H CO • PROPOSED WELL WELL • I ± 4 HD OF A,,, �.*...9TH f I� KENNETH M. D S / CE -7116 4 Www/ p�FESSI0I5A�' ./ 16A8Y WITHIN 200' OF SEPTIC SYSTEM CO V ��• TH2 MT 70' Co � a a DIVERTER'' p SEPI R 11' 1 1 11.1 N mm'JY w 0 mm'As' w Iss.laT 165m' Ioi SNOWLINE DRIVE NO WELLS WITHIN 200' OF SEPTIC SYSTEM FOR: DAN ROBERTSON 4751 MARS ANCHORAGE, ALASKA 99507 KND ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK, 99577 (907)696-6111/Fax (907)696-8111 DATD 6-1-96 DRAWING N SCALE: 1' = 100' 96011-S1 DESIGN DETAILS WASTEWATER ABS❑RPTI❑N SYSTEM LOT 1, SN❑WLINE S/D 00 0 0 0 U U U U OU U £ O 1250 GAL SEPTIC 5' MIN. T TO 4' SOLID FROM HOUSE Q M.T. FINISHED GRADE/ORIGINAL GRADE 1.5' LOWER UNCLASSIFIED FILL FROM EXCAVATI❑N 2" HD INSULAT CONNECT TO 4' SOLID FROM HOUSE C.O. O C.O. O C.O. C.O. C.O. 70' CONNECT TO RESERVE FIELD OF AZ KENNETH t 1 `ted p7''CFESSIOIS ILTER FABRIC SCREENED ROCK 70' 0.5' N TOTAL EXCAVATI❑N DEPTH FROM ORIGINAL GRADE 4' WATER OBSERVED AT 8' -T- DESIGN DESIGN DETAILS 1. 4 BDRMS X 150 GPD = 600 GPD. 2. 600 GPD/1.2 GPD PER SQ. FT. = 500 SQ. FT. 3. 500 SQ. FT./5 ' WIDE X .70 R. F. FOR 2' = 70' 4. USE TRENCH 70' L, 5' W, 2' GRAVEL 5, TOTAL DEPTH OF SYSTEM WILL BE 4.0' BELOW ORIGINAL GRADE, 6. 2' HD INSULATION TO BE INSTALLED OVER FIELD AND SEPTIC TANK, 7. CONTRACTOR TO VERIFY AND INSURE 27 GRADE FROM HOUSE. 8. CONSTRUCT PRIMARY & RESERVE FIELDS AT THE SAME TIME. CONNECT TO PROPOSED DIVERTER. ': 'A: 1 -' DAN ROBERTSON 4751 MARS ANCHORAGE, ALASKA KND ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK, 99577 (907)696-6111/Fax (907)696-8111 99507 DATE: 6-1-96 DRAWING # SCALES NTS 96011-52 Municipality of Anchorage t DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: &obef A912 DATE PERF LEGAL DESCRIPTION: p7 S/�OI�J�/%C�i d/ice Township, Range, Section: �y# DEPTH SLOPE SITE PLAN (FEET) �P16w 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS w�Cod��cs l'aM/YSa ,121 M WAS GROUND WATER ENCOUNTERED? j'es S L D P E S2/ 9 IF YES, AT WHAT DEPTH? Depth to Water After Monitoring? /5, Date: Reading Date Gross Time Net Time Depth to Water Net Drop .5 /3 G;3 — G • — I : yo 3y. - Z Lo:yZ r i J 3f3" 7 3 :,13 7/& wu r61 Z16 — z S nirl �31g' k yg„ PERCOLATION RATE_L_L L (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN V FT AND J FT PERFORMED BY: "Z) CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: TA6 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST �/ / /!� 'rutESSivs PERFORMED FOR: xxeD _-z/SO DATE PERFORMED: // C � LEGAL DESCRIPTION: C-l��� ✓/")D/•!!�/%P� S�� Township, Range, Section: FJ DEPTH SLOPE SITE SITE PLAN (FEET) I I 1 2 — 3- 4 5 6- 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS DG 12Caid' 19 S���rGveL WAS GROUND WATER ENCOUNTERED? S L O P E 2/ IF YES, AT WHAT DEPTH? -'eb Depth to Water After Monitoring? Date: ®®®® Depth •••:.a tia :a na an as. •°s 0�Y e =12=105�r�r�r�s���� �/ / /!� 'rutESSivs PERFORMED FOR: xxeD _-z/SO DATE PERFORMED: // C � LEGAL DESCRIPTION: C-l��� ✓/")D/•!!�/%P� S�� Township, Range, Section: FJ DEPTH SLOPE SITE SITE PLAN (FEET) I I 1 2 — 3- 4 5 6- 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS DG 12Caid' 19 S���rGveL WAS GROUND WATER ENCOUNTERED? S L O P E 2/ IF YES, AT WHAT DEPTH? -'eb Depth to Water After Monitoring? Date: ®®®® Depth =12=105�r�r�r�s���� PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND - FT PERFORMED BY: IfIlOd f I �P12 Dfie CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MU CIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85)