Loading...
HomeMy WebLinkAboutCAMPBELL POINT BLK 1 LT 6Campbell Point Block 1 Lot 6 #011-262-20 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 3 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP131127 PID Number. 011-262-20 Dwelling: ® Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ® New ❑ Upgrade Name: S inell Homes Inc. ASSORP71ON FIELD ❑ Deep Trench ® Shallow Trench ❑ Bed ❑ Mound Address 1900 W. North. Lts. Blvd., #200 Anch., AK 99517 Cl Other Phone Number of Bedrooms Soil Rating Total depth from original grade 344-5678 Five (5) .8 GPD/SF 10.2-11.3 Ft. LEGAL DESCRIPTION Depth to pipe invert tom original gradeGravel 6.2-7.3 t Ft. depth beneath pipe O Ft. Subdivision Block Lot Campbell Point 1 6 Fill added above original grade 0-1 Ft Gravellength 94 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines I Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trench" -between trenches From Tank Field Tank Line _ 940 Fe 2 >10 Ft. Well >100' >100' N/A N/A >25' TANK N Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,500 Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A Steel TWO NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at In. Pump make and model Electrical Inspections performed by Installer Ink ld D3034 PIPE MATERIAL Horse to tank D3034 Pomraning Excavation Drain9eld F810 Co/Mr Inspector MEA BENCHMARK (Assumed elevation) 100.0 It Ins tlea 8/4/13 $/5/13 Location and description es:t` 2� 3m $/7/13 4"' Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's stamp Conditional ��a�aap e�. Approval: Date .•�P; -^"""" 49th f , E. ANDERSON •' j }MICHAEL No. CE -4381a=- Approved Z,/ Date pa 'Noe VaaksESS.k� Inspection Report -9-1-1246c Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT Permit Number: OSPI31127 4700 Elmore Road Anchorage, AK. 99519-6655 -343-7904 PLAT NO. 66-78 y�Ty CAMPBELL POINT SUBDIVISION LOT 6 BLOCK 1 43 1275 S.F. 4 MICHAEL E. ANDERSON No. CE -4361 - Five Bedroom Home O ALTERNATE SITE Advantex Treatment System w/21' Long x 3' Wide by 6' Effective Depth Absorption Trench. Application Rate 3 GPD/SF. 0 m PLAN AS -BUILT SCALE V = 30' J b z Page 2 of 3 PID NO.: 011-262-20 Im LEGEND Mt - Monitor Tuba FCO - Foundation Clean Out TH - Test Hole Cl - Clean Out FSV - Flow Splitter VaNe Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP131127 03.0 y y UU ti Exlstlre Finsh Grouts G au 1,500 Gallon Septic Tank 7.9 9 .75 Page 3 of 3 PID No. 011-262-20 6-20-2013 EAST TRENCH U 6-20-2013 WEST TRENCH PROFILE AS -BUILT C:NICHAEL E. ANDERSON •' i. No, cE-�.ael No Scale'{ ssia'�s� EM. 96.7 Certified Drilling Log VULLIVANDOC cWATER WELLS "P.O. Box 670269, Chugiak, AK 99567 BOB -2759 OWNER OF LAND: Spinell Homes —Jeff & Kathie Hoehne ADDRESS: LEGAL DESCRIPTION Campbell Point BILK 1 Lot 6 DATE: 7/11/13 PERMIT NUMBER: 131127 DATE OF ISSUE: 6/14/13 TAX IDENTIFICATION NUMBER 01126220000 Is well located at approved permit location: 0 Yes ❑ No Method of Drilling: ®air rotary ❑ cable tool Depth of Well: 315 Casing Type: steel Wall thickness ,250 inches Diameter: 6 inches, depth 315 Static Water Level 220 feet Recovery Rate 15 ® gpm ❑ gph Method of Testing air Well Intake Opening Type: ® open end ❑ open hole ❑screened Start feet Stopped feet Grout Type: Volume: Bentonite chips Depth: from 0 feet, to 20 feet Well Disinfected Upon Completion: ® yes ❑ no Method of Disinfection: Chlorine 50 ppm Comments: Click here to enter text. Bore Hole Data Depth From To 0 2 2 4 4 12 12 65 65 111 111 280 280 310 310 315 Casing Stickup Overburden Sand Sand w/ Gravel Silt & Sand Silt Sand & Gravel Silt w/ Sand Sand Gravel & Water Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. Matsu Borough: Department of Environmental Conservation. Development Services Department N-61ding Sefeiy Division E On—Site Water A Wastewater Prr14r, am r°epe a4�`a 4700 Elmore Road P.Q. Box 196650 <Mill MarkBegieh Anchorage, AK 99507 Mayor wm.munwralorsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SWj—?L I A Date of Issue: ��13 Parcel Identification Number:` a i/ a GAA &00 0 Legal Description Property Owner Name & Address Pump Installation Date: Pump Intake Depth Below Top of wen Casing: 0 70feet Pump Manufacturer's Name:6ou )dam Pump Model: -755l04Q C t_ Pump Size 1 hp Pitless Adapter Burial Depth: `L feet Pidess Adapter Manufacturer's Name: ( ark i V1Y\t Pitless Adapter Installer � ( an r<� EX Ca trd v l0-07 Well Disinfected Upon Completion? Yes ❑ No Method of Disinfection: Comments: Pump Installer Name: ' j�VriViL — h� Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation, On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131127 Tax Code Number: 01126220000 Work Type: WellSeptic Permit Effective Dates: June 14, 2013 to June 14, 2014 Design Engineer: ANDERSON ENGINEERING Subdivision: CAMPBELL POINT Site Legal Address: CAMPBELL POINT BLK 1 LT 6 G:2322 Owner/Address: HOEHNE JEFFREY P & KATHIE A 8207 STORMY PL ANCHORAGE AK 995183010 Site Mailing Address: 8510 HEATHER CIR, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank All construction must be in accordance with: Lot Size in Sq Ft: 17275 Total Bedrooms: 5 N Privy Y Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By Issued By: MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 011-262-20 Property owner(s) Jeffrey & Kathie Hoehne Day phone Mailing address 8207 Stormy Place Anchorage, AK 99518 Site address 8510 Heather Circle Anchorage, AK Legal description (Sub'd., Block & Lot) Campbell Point, Block 1, Lot 6 Legal description (Township, Range & Section) Lot Size 17,275 Sq. Ft. APPLICATION IS FOR: (® all that apply) Absorption Field 0 Septic Tank 0 Holding Tank ❑ Privy ❑ Private Well Multiple Dwellings ❑ Water Storage ❑ Number of Bedrooms Five (5) APPLICATION IS AN: TYPE OF DWELLING: Initial 0 Single Family (SF) (w/wo ADU) Upgrade F-1Duplex (D) ❑ Renewal ❑ Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. property owner or authorized agent) Permit/Rush Fees: 1 �� Date of Payment: (o �1b l I Ch Receipt Number: OSSt-Igi'1G Permit No. os? 1�)lNa-1 Permit App_9-1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. June 9, 2013 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 6, Block 1, Campbell Point Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 6, Block 1, Campbell Point Subdivision intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test hole placed on the lot in the area of the absorption trenches and alternate site indicate silty sand (SM/SW). The percolation rate of the soil was determined to be 10- 11 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500 -gallon septic tank and 2-30' long by 3' wide by 8' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 2' below the surface and the total depth will be 10'. A flow splitter valve will be placed to insure even flow to each trench. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the southwest at a shallow grade with some cross sloping from the east. The new trenches will be Lot 6, Block 1, Campbell Point Subdivision June 9, 2013 Page Two constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, W E auj'.' Michael E. Anderson, P.E. Attachments MICHAEL E. ANDERSON No. CE -4381 PLAT NO. 66-78 CAMPBELL POINT SUBDIVISION LOT 6, BLOCK 1 17,275 S.F. h 1Ds �TNFR cin,CL� N <a s?$T Rego. 100' 3 ^< ac A I Five Bedroom ALTERNATE SITE r"6 \*� Home� Advantez Treatment co 1,500 Gallon FCO System w/2I Long z 3' / Septic Tank / Wide by 6' Effective / \ Depth Absorption Trench. / @ / ,a Application Rate 3 / / Fsv SV / GPD/SF. / w OTH1/ / / o 2-47' Lo Be epth x 5' Wide �/ I c / x 4' Eff iD+ co* / Absorptt''pn Trenches / me I a Mi• / �/ I 10co T-122 3' / / I NOTE: I No Areas of Excessive Slope or Surface Water are Within 100' of Any Existing Part of the New Septic Proposed Well System. S 83'20'00-E 82.84' Well RELATIVE ELEVATION FROM ASSUMED DATUM 98' � o LEGEND MT - Monitor Tube •OFQF ,Al \ THO- Test Hole'on Clean Out �� •••••'•••••, CO - Clean Out /••��P•"♦j♦ DIMOND BODLEygRD FSV - Flow Splitter Valve i e 49th s . z} ♦ _ ......... ......:.... �................................... . �? MICHAEL E. ANDERSON t ♦♦�'�j+'., NO. CE -4381 •.• •. SITE PLAN . • ♦♦♦�� �j ESS SCALE 1" = 30' Go F LOT 6, BLOCK 1, CAMPBELL POINT SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Five Bedroom Home 5' Wide Trench System Perc. Rate: 10 Min./Inch 1,500 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 937.5 SF Absorption Area 937.5 SF/5 SF/LF'.5 (Red. Factor) = 93.75 LF Trench Length THEREFORE: Construct 2-47' Long x 5' Wide x 4' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trenches to be 7' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. M 50111 5' Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) �OP�E. ••qC q�.4 00 �. t NOTE: Grade Area Over Trench to Drain Away. ;' Minimum 6' Separation From Bedrock. Q, .....asm Minimum 4' Separation From Groundwater. i Minimum 100' Separation From Wells in the Area. MICHAEL E. ANDERSON Minimum 100' Separation From Surface Water or Streams: ��%, a, No. CE -036, :'�, Natural Backfill Geotextile Fabric 6" 4" Perforated O PVC (Holes Down) 50111 5' Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) �OP�E. ••qC q�.4 00 �. t NOTE: Grade Area Over Trench to Drain Away. ;' Minimum 6' Separation From Bedrock. Q, .....asm Minimum 4' Separation From Groundwater. i Minimum 100' Separation From Wells in the Area. MICHAEL E. ANDERSON Minimum 100' Separation From Surface Water or Streams: ��%, a, No. CE -036, :'�, MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 6 Block 1 Campbell Point Subd. PERFORMED FOR: Spinell Homes DATE: 6/1/13 PROJECT No.: PARCEL ID#: TECHNICIAN: JB DEPTH TEST HOLE 1 (feet) 1 OB/OG 2 3 4 5 6 SM/Sw 7 8 9 10 11 13- 14- 15- 16-- 3141516 B.O.H. 17- 18- 19— I 71819 WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? L DEPTH OF WATER AFTER MONITORING: None O DATE OF MONITORING: 6/10/13 tC DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) 1TH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 6/3/13 1 9:18 5.75" 2 9:48 30 8.75" 3" 3 9:50 5.5" 4 10:20 30 8.375" 2.875" 5 10:22 5.5" 6 10:52 30 8.375" 2.875" PERCOLATION RATE:10.4 (MIN/INCH) PERC. HOLE DIA. g (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/3/13 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 6 Block 1 Campbell Point SUbd. PERFORMED FOR: Spinell Homes DATE: 6/1/13 PROJECT No.: PARCEL ID#: TECHNICIAN: JB DEPTH TEST HOLE 2 (feet) 1 OB/OG 2 3 4 5 6 SM/Sw 7 8 9 10 11 12- 13- 15— 213 15 B.O.H. 16- 17- 18— I 61718 WAS GROUND WATER ENCOUNTERED? IN IF YES LD WHAT DEPTH' NET TIME (MINUTES) DEPTH TO WATER (INCHES) DEPTH OF WATER AFTER MONITORING:None 6/I O/13 TEST HOLE PRESOAKED PRIOR TO TESTING: DATE OF MONITORING 1 9:13 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 6/3/13 1 9:13 8.511 2 9:43 30 11.25" 2.75' 3 9:45 811 4 10:15 30 10.75' 2.75" 5 10:17 8,2511 6 10:47 30 1111 2.75" PERCOLATION RATE: 10.9 (MIN/INCH) PERC. HOLE DIA.-7—(INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/3/13 O NITORING: 6/1 �/I3 LC C, c) -=I DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) MUNICIPALITY OF ANCHORAGE Na DEVELOPMENT SERVICES DEPARTMENT -0i OF ���"CE OF a♦♦ �p ................... 1 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 �:'• ♦1 g,g �� i:' i}♦1 ' 49th 2 SOILS LOG - PERCOLATION TEST ', 11.25" 2.75" /................................................ r ',MICHAEL E. ANDERSON jAt 3 LEGAL DESCRIPTION: Lot 6 Block 1 Campbell Point SUbd. ♦♦�rj'•., No. CE -4381 g�� -6/1/13 R: Spinell Homes ♦aI �r 4 DATE:PERFO PROJECT No.: �S�� �••• 10.75" PARCEL ID#: TECHNICIAN: 113 P oCeasional Engineers Stamp: DEPTH TEST HOLE 2 (feet) 1-TmmOB/OG SLOPE SITE PLAN 2 2.75" 3 4 5 6 SM/Sw 7 8 9 O 10— WAS GROUND WATER ENCOUNTERED4 NO IF YES @ WH AT DEPTH 11 DEPTH OF WATER AFTER MO MONITORING None DATE, OF MO 12 13 14 15 16 17 18 19 20 B.O.H. C@! 21' PERCOLATION RATE:10.9 (MIN/INCH) PERC. HOLE DIA. 7 (INCHES) TEST RUN BETWEEN: 3 FT, and 4 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR To TEST. TEST HOLE DEEPENED FOR CHANGE ORDER. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 8/21/13 O NITORING: 6/1 �/I3 LC DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 6/3/13 1 9:13 g,g �� 2 9:43 30 11.25" 2.75" 3 9:45 g�� 4 10:15 30 10.75" 2.75" 5 10:17 8.25" 6 10:47 30 11" 2.75" Development Services Department On -Site Water &Wastewater Section Certificate of On -Site Systems Approval Parcel I.D. 011-262-20 1. GENERAL INFORMATION Phone: 907-343-7904 Fax. 907-343-7997 Expiration Date: (,, — 2 2 Z -Q V Complete legal description Campbell Point Sub, Block 1, Lot 6 Location (site address) 8510 Heather Circle Current property owner(s) Paul & Amanda McGrath Day phone (907) 312-0787 Mailing address 8510 Heather Circle, Anchorage, AK 99502 Real estate agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well IC Private Septic ❑■ Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ $550 Waiver Fee $ Date of Payment IO 11. Date of Payment Receipt Number. 3 Receipt Number COSA# OSC211090 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller Date 3/4/21 '�c oF'4�q�11 TH 6. DSD SIGNATURE System #1 Approved for • • • • • ' • ' / bedrooms • Benj chiller •Schiller i System #2 Approved for bedrooms�� ��`c�s••• CE 12592��� Disapproved �,,kF� ipROfESS10�P��� 'N*4& s` Conditional approval for bedrooms, with the following stipulations: Original Certificate Date:_ -Z2 -2 C�Z� The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: Campbell Point Sub, Block 1, Lot 6 Parcel ID: 011-262-20 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 7/11/13 Total depth 315 ft Cased to 315 ft 9 Sanitary seal is functioning correctly limil Wires are properly protected Casing height (above ground) 20 in. Date of flow test for COSA 3/3/21 Static water level at beginning of test 233.9 ft ••,C�Z7"1010- M, I�irel�li7��e1 Age of tank(s) 8 years Tank type/material Septic/Steel Measured operating fluid level in septic tank 50 Fmil Standpipes/foundation cleanout per record drawing Date of pumping 3/4/21 Around the Clock Pumping D. ABSORPTION FIELD DATA Shallow Trench Which system tested (date installed) $/5/13 D ALL standpipes present per record drawing Total measured depth from grade 12.2/9.4 ft (max) Measured depth to pipe invert from grade 8.4/52 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 3.8/4.2 0 Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Structure served by this system Well production at time of test 4.8 gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic 7.43 ug/L ❑ Arsenic less than MRL (ND) Collected by Forge Engineering Date of Sample 3/2/21 C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 3/3/21 Results R]Pass For 5 - bedrooms Fluid depth prior to test 0/0 in Water added 872 gal New depth 0/10 in Elapsed time 1440 min Final fluid depth 0 in Absorption rate X750 gpd Any rejuvenation treatment (past 12 months) N/A If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes Community Sewer Manhole/Cleanout > 100' 0✓ Yes if No ft M Yes if No ft Neighboring Tank > 100' F71 Yes if No ft Private Sewer/Septic Line > 25' Yes if No ft Absorption Field on Lot > 100' r-71 Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' 0✓ Yes if No ft Water Main > 10' Animal Containment > 50' 0✓ Yes if No ft F/ Yes if No ft Yes if No ft Water Service Line > 10' 0✓ Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' F/ Yes if No ft 0✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' 0✓ Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Q Absorption Field > 5' 0✓ Yes if No ft Private Wells > 100' 0✓ Yes if No ft Water Main > 10' [Z] Yes if No ft Community Wells > 200' Yes if No ft Water Service Line > 10' 0✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' 0 Yes if No ft If absorption field is under driveway comment below Property Line > 10' Q Yes if No ft Wells on Adjacent Lots: Water Main > 10' Q Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' Yes if No ft Community Wells > 200' 0✓ Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet low'. QT r.. . ;; ......... Benjarr.schiller ¢���'F��• . CE 12592 . •,``4 7, Aw ll� ROFESSt40,�-®. MUNICIPALITY OF ANCHORAGE l Development Services Department \ `-= " � Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On-Site Systems Approval Parcel I.D. 011-262-20 Expiration Date: �/!-, 1. GENERAL INFORMATION Complete legal description Campbell Point, Block 1 , Lot 6 Location (site address) 8510 Heather Circle Anchorage, AK Current property owner(s) Adam & Fritha Breidinger Day phone (907) 529-9050 Mailing address 8510 Heather Circle Anchorage AK 99502 Real estate agent Day phone 2. TYPE OF DWELLING: E Single Family (w/wo ADU) n Duplex H Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Private Septic Water Storage H Holding Tank Community Well n Community Public Water System Public Sewer n Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ S Waiver Fee $ Date of Payment 2//21/ f Date of Payment Receipt Number Oil (965-D Receipt Number COSA# CSC 1R i 0-3 �l Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 2/11/19 ���aaaaaa+R 4.4"1-.°t- ••• \>-...••• s • • 6. DSD SIGNATURE • 11 fit System #1 Approved for bedrooms f• }MICHAEL E. ANDERSON N/.41 • ff •C%;a No. CE-4381 {�= System #2 Approved for bedrooms ••,�FQ�..ti•2/25/19�.e' r Disapproved ,+h�vtRs ..:.4• Conditional approval for bedrooms, with the following stipulations: ON-SITE m WASTEWWATER ANDATER PROGRAM M1 A. SEROC' By: , - Original Certificate Date: 3 _J/• `1 The Municipality of Anchorage Development Services Division (DSD)issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Campbell Point B1 L6 Parcel ID: 011-262-20 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system A. WELL DATA 0 Well log is filed with Onsite (or attached) Well production at time of test 4.1 gpm Date drilled 6/14/13 Water storage tank volume N/A gallons Total depth 315 ft Well disinfected for coliform test? ❑ Yes ❑■ No Cased to 315 ft ❑■ Coliform bacteria is Negative ■❑ Sanitary seal is functioning correctly Nitrate mg/L It Nitrate less than MRL(ND) ['Wires are properly protected Arsenic 9.51 ug/L ❑Arsenic less than MRL (ND) Casing height(above ground) 24 in. Collected by Forge Engineering Date.of flow test for COSA 2/5/19 Date of Sample 2/6/19 Static water level at beginning of test 233 ft. Comments B. TANK DATA C. LIFT STATION Age of tank(s) 5 years ❑ Required maintenance completed Tank type/material "`' Age of lift station years Measured operating fluid level in septic tank 50 Lift station material ■❑ Standpipes/foundation cleanout per record drawing Comments: Date of pumping 2/5/19 D. ABSORPTION FIELD DATA 5-Wide Shallow Trench Which system tested (date installed) 8/5/13 Adequacy test date 2/5/19 ■❑ ALL standpipes present per record drawing Results ['Pass For 5 bedrooms Total measured depth from grade 10/12 ft(max) Fluid depth prior to test 13/0 in Measured depth to pipe invert from grade 6/8 ft(min) Water added 1171 gal ❑ N/A—pressurized field New depth 38/0 in O Monitor tubes go to bottom of effective. If not, state Elapsed time 1440 min depth into effective Final fluid depth 20/0 in El Code-required soil cover over field Absorption rate >750 gpd ❑ System presoaked No (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) date of test) gallons Gallons introduced N/A If yes, enter date Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout> 100' 0 Yes if No ft 0 Yes if No ft Neighboring Tank> 100' 0 Yes if No ft Private Sewer/Septic Line > 25' El Yes if No ft Absorption Field on Lot> 100' 0 Yes if No ft Holding Tank > 100' 0 Yes if No ft Neighboring Absorption Fields > 100' Animal Containment> 50' 0 Yes if No ft 0 Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' 0 Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water> 100' 0 Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' 0 Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' El Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' 0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' 0. Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' El Yes if No ft Water Service Line > 10' 0 Yes if No ft Community Wells>200' El Yes if No ft Surface Water> 100' El Yes if No ft F. ENGINEER'S COMMENTS 4744 G. ENGINEER'S CERTIFICATION .44���, .IR,,,,..... .. AP(79\•••• S. t I certify that l have determined through field inspections and review s `4 '•.•• .. of Municipal records that the above systems are in conformance with i 4 49th 1\ , MOA COSA guidelines in effect on this date. S11iraH1111f11 11t1111 111111K111 1111„ 11,E„111111! im reams, ..a ......w.... MICHAEL E. ANDERSON I j ♦��'� ''•. No. CE-4381 �•'��- ` < ••NI 2/18/19 ••6411•'`t11 COSA Checklist yellow sheet ;T.a el) •1111.11■11.11111111••'' x, \4••m • '� Municipality of Anchorage On -Site Water and Wastewater ProgW (907)343-7904 x,. Certificate of On-Siite systems- proval Parcel I.D. 011-262-20 I !� Expiration Date: -� 7 1. GENERAL INFORMATION ) Li Complete legal description Campbell Point, Block 1, Lot G Location (site address) 8510 Heather Circle Anchorage, AK Current Property owner(s) Spinell Homes, Inc. Day phone Mailing address Real Estate Agent 2. TYPE OF DWELLING: 344-5678 1900 W. Northern Lights Blvd., #200 Achorage, AK 99517 Day phone F� Single Family (w/wo ADU) ❑Duplex SUBMITTAI ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Five JAN 2 4 2014 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System 71 Public Sewer ❑ Waiver/Variance request for: Disi Received by: COSA to be released�fo the engineer, unless otherwise requested by the engineer. COSA Fee $ (,9 ?u I A )�(Ar, 1 Date of Payment I label Receipt Number 0015D_ G COSA# o,)C114Io1�" } Date: Waiver Fee $, Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE _ _System #1 Approved for J bedrooms System #2 Approved for bedrooms Disapproved 522-7773 Date 1/20/2014 Conditional approval for bedrooms, with the following stipulations: By: ��� ir� Tit% . Original Certificate Date: 1-2 i - % The m.. lity o Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other CASA f . sheet E - c If more than 1 septic system is on the lot: COSA Checklist # _of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Campbell Point, Block 1, Lot 6 Parcel ID: 011-262-20 A. WELL DATA Well type Private Date completed 7/11/13 Total depth 315 ft Date of test Static water level Well production If A, B, or C provide PWSID # _ Sanitary seal (Y/N) Y Cased to 315 ft FROM WELL LOG 7/11/13 WATER SAMPLE RESULTS 220 ft. 15 g.p.m. Coliform 0 colonies/100 mL Nitrate 4 1) mg/L Arsenic S 13 ug/L Date of sample: 1/14/14 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,500 gal. Number of Compartments 2 Well Log (Y/N) Y Wires properly protected (YIN) Y Casing height (above ground) >18 in. AT INSPECTION ft. g.p.m. Collected by: Anderson Engineering Date installed 8/4/13 Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (YIN) Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA Date installed 8/5/13 Length 94 ft Total depth 10-12 ft. Eff. absorption area 940 ft? N C t Y Soil rating (g.p.d./ft? or fe/bdrm) .8 GPD System type 5' Wide Width 5 ft. Gravel below pipe 4.0 ft. Monitoring tube Y Depression over field N Date of adequacy test ew OnS . Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date D. LIFT STATION Date installed Size in gallons_ "Pump on" level at in. "Pump off" level at Datum Cycles tested _ E. SEPARATION DISTANCES Septic tank/lift station on lot >100' Absorption field on lot >100, Public sewer main NIA Sewer ]septic service line >25' Animal containment areas >50' SEPTIC/HOLDING TANK ON LOT TO: >5' — Manhole/Access (Y/N) in. High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots On adjacent lots >100' >100, Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas >100' >5' Building foundation Property line 1 Water main > Water service line >10, Wells on adjacent lots >100' ABSORPTION FIELD ON LOTTO: Property line >10' Building foundation >10' Water Service line >10' Surfacewater >100' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineers Printed Name Michael E. Anderson, P.E. Date 1/20/14 COSA brown sheet -1 0-10-1 z.doc Absorption field >5' Surface water >100, Watermain >10' Driveway, parking/vehide storage >10'